Jida Xiaotian'e
Filter
Showing all 24 results
| Brand | Jida Xiaotian’e |
|---|---|
| Model | GDYQ-100A2 |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 0.0–500.0 mg/kg |
| Accuracy | ±2% |
| Assay Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded MCU with data logging, parameter configuration, statistical analysis, and USB/RS232 connectivity |
| Sample Prep | Dedicated extraction kit and single-use reagent cartridges |
| Compliance | Designed per GB 5009.287–2023 (National Food Safety Standard – Determination of Formaldehyde Sulfoxylate in Foods) |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-300S |
| Pricing | Upon Request |
| Light Source | High-brightness LED |
| Wavelength | 538 nm |
| Detection Limit | 0.10% (L-hydroxyproline) |
| Measurement Range | 0.00–40.00% (w/w L-hydroxyproline) |
| Accuracy | ±5% |
| Sample Throughput | 20 samples/hour |
| Digestion Time | 15 min (catalytic digestion) |
| Light Source Lifetime | ≥100,000 hours |
| Integrated Optical Design | LED-based solid-state light source acting as both emitter and monochromator |
| Display | Large backlit LCD with Chinese interface |
| Data Output | Built-in thermal printer (sample ID, matrix type, concentration, date, operator ID) |
| Calibration | Zero-point calibration only |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-Analyte (Simultaneous Detection of >30 Parameters) |
| Sample Compatibility | Universal for Solid, Semi-Solid, and Liquid Food Matrices |
| Wavelength Range | 400–630 nm |
| Assay Time | 3–20 minutes per test |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | OEM Producer |
| Region Classification | Domestic (China) |
| Model | GDYQ-121SD |
| Pricing | Upon Request |
| Light Sources | 254 nm UV, 365 nm UV, and Visible Light |
| Imaging Sensor | CCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V ±20 V, 50–60 Hz / Rechargeable Li-ion Battery (12.6 V / 2600 mAh) |
| Power Consumption | ≤20 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90 % RH |
| Image Storage Capacity | >1000 images |
| Detection Time | ≤60 s per sample |
| Compliance Standard | NY/T 1257–2006 (Pesticide Residue & Fluorescent Substance Testing in Edible Fungi) |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-5000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Sesame Oil Only |
| Detection Time | 20 min |
| Quantification Range | 0.0–100.0% |
| Detection Limit | 3.0% |
| Accuracy | ±2% |
| Brand | Jida Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GDYS-102SK |
| Price Range | USD 280–1,400 (FOB) |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameter | Permanganate Index (COD<sub>Mn</sub>) |
| Detection Limit | 0.50 mg/L |
| Measurement Range | 0.00–8.00 mg/L |
| Accuracy | ±5% of reading |
| Method | Micro-titration with pre-packaged reagent kit |
| Analysis Time | ≤10 minutes per sample |
| Sample Matrix | Drinking water and raw water sources with chloride concentration <300 mg/L (as Cl⁻) |
| Brand | Jida Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-301MA |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measurable Parameters | Free Chlorine, Total Chlorine, Ozone, Fluoride, Ammonia Nitrogen |
| Display | 5-inch Color Touchscreen + 2.9-inch E-Ink Screen |
| Calibration | Pre-loaded Calibration Curves (No Standard Solution Preparation Required) |
| Data Storage | Up to 10,000 Test Records with Conditional Search |
| Connectivity | Bluetooth for Wireless Printing |
| Compliance Context | Designed for field-deployable compliance screening per GB/T 5750 (China’s Standard Methods for Examination of Drinking Water), supports GLP-aligned data traceability |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYJ-501SP |
| Measurement Range | Formaldehyde: 0.0–125.0 mg/kg |
| Hexavalent Chromium | 0.0–50.0 mg/kg |
| Wavelengths | 412 nm (formaldehyde), 540 nm (Cr(VI)) |
| Detection Limits | Formaldehyde: 2.0 mg/kg |
| Cr(VI) | 0.5 mg/kg |
| Accuracy | ±5% |
| Operating Temperature | 10–40 °C |
| Power | 5 W |
| Input Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Display | 5″ color TFT touchscreen + 2.9″ e-ink customizable standby screen |
| Data Storage | ≥10,000 test records with conditional search |
| Connectivity | USB 2.0, RS232, Bluetooth (for wireless thermal printer) |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYK-160L / GDYK-160H |
| Instrument Type | Single-Channel Passive Air Sampler |
| Flow Range | GDYK-160L: 0–0.5 L/min |
| GDYK-160H | 0–1.0 L/min |
| Flow Stability | ≤5% |
| Flow Accuracy | ±3% |
| Operating Temperature | 10–40 °C |
| Continuous Operation Time | >8 h |
| Timer Accuracy | <0.1% |
| Display | High-Density Dot-Matrix LCD (Low-Power, Sunlight-Readable) |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYK-90 |
| Instrument Type | Conventional Dual-Channel Gas Sampler |
| Flow Range | 0.1–1.5 L/min |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ±5% |
| Flow Repeatability | ≤2% |
| Timing Accuracy | ±0.2% |
| Temperature Display Accuracy | ±2 °C |
| Sampling Volume Range | 1–50 L |
| Sampling Delay Range | 0–999 min (1 s resolution) |
| Display | High-Density Dot-Matrix LCD with Adjustable Backlight |
| Battery | 9600 mAh Li-ion, ≥8 h continuous dual-channel operation |
| Auto-Power-Off Timeout | Configurable |
| Refresh Interval | 1 s |
| Standard Volume Calculation | Automatic post-sampling conversion |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1012SD |
| Detection Methods | Enzyme Inhibition Assay, Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates & Carbamates Inhibition Rate: 0–100% |
| Organochlorines | 0.0–40.0 mg/kg |
| Pyrethroids | 0.0–40.0 mg/kg |
| Number of Channels | 12 |
| Measurement Error | ±10% |
| LOD | Organophosphates & Carbamates: 0.01–3.0 mg/kg |
| Organochlorines | 0.3 mg/kg |
| Pyrethroids | 0.3 mg/kg |
| Light Sources | High-brightness LEDs at 405 nm and 254 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Dimensions | 470 × 280 × 180 mm |
| Weight | 3.6 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1 Hz |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYS-101SE2 |
| Instrument Type | Portable |
| Measurement Principle | DPD-based Spectrophotometry |
| Measured Parameter | Chlorine Dioxide (ClO₂) |
| Measurement Range | 0.00–3.00 mg/L |
| Accuracy | ≤5% |
| Repeatability | ±0.01 mg/L |
| Resolution | 0.01 mg/L |
| Limit of Detection (LOD) | 0.02 mg/L |
| Light Source | 520 nm LED |
| Photometric Stability | ±0.005 Abs / 20 min |
| Measurement Time | 1 minute |
| Operating Temperature | 15–40 °C |
| Power Supply | DC 9 V (battery-powered) |
| Dimensions | 170 × 90 × 35 mm |
| Weight | 300 g |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-201MC |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | Free Chlorine, Total Chlorine, Ozone, Turbidity, Fluoride, Nitrite Nitrogen, Ammonia Nitrogen, Dissolved Oxygen |
| Light Source | High-Brightness LED |
| Optical Stability | 0.005 Abs/h |
| Sample Cell | Cylindrical Glass Cuvette & Standard Glass Cuvette |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Rechargeable Battery | 7.4 V / 1800 mAh |
| Operating Temperature | 5 °C to 40 °C |
| Connectivity | USB, RS232, Bluetooth (for wireless printing) |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-900M |
| Instrument Type | Portable/HANDHELD Water & Air Quality Analyzer |
| Detection Parameters | Residual Chlorine, Total Chlorine, Ozone, Chlorine Dioxide, Ammonia Nitrogen, Sulfide (Water) |
| Light Source | High-Brightness LED |
| Wavelengths | 380, 430, 470, 520, 538, 595, 630 nm |
| Photometric Stability | ≤0.005 Abs/h |
| Operating Temperature | 5–40 °C |
| Detector | Integrated Photodiode Sensor |
| Sample Cell | Cylindrical Glass Cuvettes & Standard Glass Cuvettes |
| Power Supply | AC/DC Dual Mode |
| Data Storage | 32 GB internal flash memory |
| Connectivity | USB 2.0, RJ45 Ethernet, Built-in Wi-Fi (IEEE 802.11 b/g/n) |
| Display | Color TFT Touchscreen |
| OS | Windows Embedded Standard 7 |
| Onboard Software | Preloaded calibration curves, sample metadata entry (sample ID, analyte, operator, lab name), audit-ready data logging |
| Printing | Integrated thermal printer + external printer support via USB/Ethernet/Wi-Fi |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYK-160 |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0.5 L/min |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ≤±5% |
| Temperature & Pressure Measurement | Integrated High-Precision Sensors |
| Operating Temperature | -10–45 °C |
| Continuous Operation Time | ≥8 h |
| Flow Error | ≤±3% |
| Timing Accuracy | <0.1% |
| Pump Design | Custom Rubber Diaphragm with Dual-Ball-Bearing Motor |
| Acoustic Noise Reduction | Engineered Passive Damping System |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYK-202S |
| Detection Principle | Colorimetric Method (MBTH-based spectrophotometry) |
| Measurement Range | 0.00–1.00 mg/m³ (at 10 L sampling volume) |
| Sampling Method | Pump-aspiration |
| Light Source | High-brightness LED |
| Wavelength | 630 nm |
| Detection Limit | 0.01 mg/m³ (at 10 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | 9 V rechargeable lithium battery |
| Compliance | GB/T 18204.2–2014 |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1020SD |
| Detection Methods | Enzyme Inhibition, Thin-Layer Chromatography (TLC), Colloidal Gold Immunochromatography |
| Measurement Range | 0.0–100.0% (relative inhibition or signal intensity) |
| Number of Channels | 20 |
| Optical Stability | ±0.005 A/20 min |
| Sensitivity | 0.01–3.0 mg/kg (matrix-dependent) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Display | 10-inch capacitive touchscreen |
| OS | Windows Embedded |
| Data Output | Dual-printing support (integrated thermal printer + external USB/LAN printer) |
| Power | Rechargeable Li-ion battery + AC adapter |
| Portability | Integrated carry case with detachable control unit and field imaging module |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic (China) |
| Model | GDYN-200S |
| Product Type | True Protein Analyzer |
| Measurement Principle | Colorimetric Protein Assay (Biuret-based) |
| Measurement Range | 0.5–4.0% (liquid milk) |
| Detection Limit | 0.5% (liquid milk) |
| Precision | ±3% RSD |
| Light Source | Silicon Photodiode |
| Operating Temperature | 15–35 °C |
| Power Supply | 220 V AC, 50 Hz |
| Interface | RS-232 / USB |
| Data Output | Integrated thermal printer + digital export |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-121SG |
| TPM Resolution | 0.1% |
| TPM Response Time | <15 s |
| Oil Temperature Range | +10 to +200 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensor | PTC |
| IP Rating | IP65 |
| Housing Material | ABS |
| Weight | <170 g |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYQ-131SA |
| Detection Time | 10 s |
| Detection Range | 0–9999 RLU |
| Limit of Detection | 4×10⁻¹⁸ mol ATP |
| Detection Lower Limit | 1 CFU/mL |
| Repeatability | ≤15% CV |
| Correlation Coefficient | ≥0.995 |
| Measurement Error | ±5% or ±5 RLU |
| Threshold Groups | 100 |
| Data Storage Capacity | >2000 records |
| Operating Temperature | 5–40 °C |
| Operating Relative Humidity | 20–80% RH |
| Weight | ~260 g |
| Battery Life | Up to 20 h continuous operation |
| Interface | USB/Bluetooth data export |
| Software Compatibility | Windows-based analysis suite with pass/fail logic engine |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SF |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Analyte | Fluoride |
| Detection Limit | 0.01 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Analysis Time | ≤30 minutes |
| Method Compliance | GB/T 5750.5–2006 |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SG |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Target Analyte | Hexavalent Chromium (Cr(VI)) |
| Detection Limit | 0.01 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Method Compliance | GB/T 5750.6–2006 |
| Analysis Time | ≤3 minutes per sample |
| Reagent Format | Single-use, pre-packaged test kit |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SL |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Method (Standardized Molybdenum Blue Reaction per GB 11906–1989) |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% of reading |
| Detection Limit | 0.02 mg/L |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-MW400 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | Total Phosphorus, Ammonia Nitrogen, Total Nitrogen, Chemical Oxygen Demand (COD) (High-Range & Low-Range) |
| Wavelengths | 380 / 430 / 470 / 520 / 538 / 595 / 630 nm |
| Photometric Stability | ±0.005 Abs/h |
| Detector | Integrated Photodiode Sensor |
| Light Source | High-Brightness LED (100,000 h lifetime) |
| Sample Cells | 19 mm cylindrical glass cuvettes & 50 mm rectangular glass cuvettes |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz / Rechargeable Li-ion battery (8.4 V, 1800 mAh) |
| Operating Temperature | 5–40 °C |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Data Interfaces | USB 2.0, RS-232 |
| Connectivity | Bluetooth (for printer pairing), PC software for Excel export and report generation |