| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NJ-IA |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Detection Channels | 20 |
| Measurement Error | < 0.01 Absorbance Units |
| LOD (Dichlorvos) | ≤ 0.2 mg/L |
| Additional LODs | Parathion ≤ 0.8 mg/L, Chlorpyrifos ≤ 0.16 mg/L, Phoxim ≤ 0.2 mg/L, Methamidophos ≤ 1.2 mg/L, Carbaryl ≤ 0.24 mg/L, Malathion ≤ 1.5 mg/L, Carbofuran ≤ 0.04 mg/L, Methomyl ≤ 0.1 mg/L, Isoprocarb ≤ 0.28 mg/L, Omethoate ≤ 0.44 mg/L, Dichlorvos ≤ 0.1 mg/L |
| Brand | Charm |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | novaLUM II-X |
| Detection Method | Bioluminescence-based Assay for Organophosphates & Carbamates |
| Measurement Scope | Cereals & Oils, Vegetables, Fruits, Dairy Products |
| Intra-instrument Precision | CV ≤ 15% |
| Detection Time | ≤15 min (for target analytes) |
| Sensitivity | 100–1000× higher than conventional enzyme inhibition assays |
| Sample Preparation | Minimal—aqueous samples (e.g., milk, water) require no extraction or purification |
| Reagent Shelf Life | 12 months at 2–8 °C |
| Instrument Power | Rechargeable Li-ion battery (≥9 h continuous operation) |
| Data Interface | USB 2.0 + integrated Wi-Fi module for real-time data transmission and report export |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | Swing |
| Detection Method | Enzyme Inhibition Rate Method (Spectrophotometry) |
| Application Domain | Food Safety & Pesticide Residue Analysis |
| Compliance Framework | Designed for GLP/GMP-aligned laboratories |
| Automation Level | Fully Integrated Robotic Platform |
| Brand | DreTop |
|---|---|
| Origin | Shanghai, China |
| Model | DTPN-1020 |
| Detection Method | Enzyme Inhibition Rate Method (Spectrophotometric) |
| Measurement Range | 0–100% inhibition rate |
| Number of Sample Positions | 20 |
| Active Detection Channels | 3 |
| Measurement Accuracy | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Optical Source | High-Brightness LED |
| Wavelength | 405 ± 10 nm |
| Photometric Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Dimensions | 430 × 330 × 170 mm |
| Compliance | Designed to support GB/T 5009.199–2003, NY/T 448–2001, and related Chinese national standards for pesticide residue screening |
| Brand | DreTOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DTPN-308S |
| Pricing | Available Upon Request |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0.0–100.0 % Inhibition Rate |
| Number of Channels | 8 |
| Active Detection Channels | 1 (simultaneous 8-channel optical readout) |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg (matrix-dependent, per WHO/FAO JMPR reference compounds) |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-106SD |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% |
| Sample Throughput | 6 samples per run |
| Assay Time | ≤13 minutes per batch |
| Compliance Standard | GB/T 5009.199–2003 |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging and statistical processing |
| Sample Prep | Integrated dedicated pretreatment kit and single-use reagent cartridges |
| Brand | Jilin University Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-308S |
| Pricing | Available Upon Request |
| Detection Principle | Acetylcholinesterase (AChE) Inhibition Assay |
| Target Analytes | Organophosphorus & Carbamate Pesticides |
| Sample Throughput | 8 samples per run |
| Detection Time | ≤13 minutes per batch |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% (relative to reference standard) |
| Brand | Hexin Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Model | TAPI-TOF 1000 |
| Pricing | Available Upon Request |
| Detection Method | Thermal-Assisted Plasma Ionization (TAPI) coupled with Time-of-Flight Mass Spectrometry |
| Measurement Range | Customizable per pesticide analyte (validated per EU SANTE/11312/2021 & GB 2763-2021 guidelines) |
| Channel Capacity | High-throughput single-channel sequential analysis |
| Detection Channels | Single ionization source with multiplexed spectral acquisition |
| Measurement Uncertainty | Compliant with ISO/IEC 17025:2017 for qualitative screening |
| Limit of Detection (LOD) | Sub-ng/g level for >300 priority pesticides in matrix-matched calibration |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-QN40 |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 40 |
| Wavelength | 410 nm |
| Light Source | Monochromatic Cold Light Source |
| Sample Capacity | 40 Positions |
| Reaction Vessel Temperature | 37 ± 0.1 °C |
| Reaction Cycle Time | 42 s per test |
| Reagent Positions | 4 |
| Reagent Needle | Liquid-Level Sensing & Collision Protection |
| Display | 7-inch Touchscreen |
| Printer | Built-in Thermal Printer |
| Power Supply | AC 220 V, 50 Hz, 102 W |
| Weight | ~13 kg |
| Dimensions | 428 × 305 × 380 mm |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1016SD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 16 |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | High-brightness LED |
| Wavelength | 405 nm |
| Optical Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz / Built-in Rechargeable Li-ion Battery |
| Data Storage | 32 GB internal + MicroSD expansion |
| Connectivity | Micro-USB, Micro-HDMI, Wi-Fi, GPRS/EDGE |
| OS | Embedded Windows-based interface |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYN-1024SC |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ±6% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | Silicon Photodiode |
| Wavelength | 405 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Inhibition Rate Range | 0–100% |
| Precision | ±6% |
| Detection Limit | 0.01–3.0 mg/kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYN-1096SC |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 96 |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Inhibition Range | 0–100% |
| Inhibition Accuracy | ±6% (at 50% inhibition) |
| Throughput | Up to 192 samples per hour |
| Data Storage Capacity | 1024 records |
| Interface | RS-232 / USB |
| Display | Full-Text LCD (Chinese) |
| Reagent Compatibility | Imported cholinesterase-based reagents (500-test kit included) |
| Optical Architecture | Solid-state array light source and detector per channel |
| Expected Service Life | >10 years |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-110SA |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 10 |
| Temperature Display Accuracy | ±0.5 °C |
| Colorimetric Timing Precision | ±1 s |
| Standard Reaction Time | 3 min |
| Input Voltage | 100–240 V AC |
| Rechargeable Battery Runtime | 100–150 min |
| Adjustable Incubation Time Range | 1–99 min |
| Operating Environment | Indoor & Vehicle-Mounted |
| Operating Temperature Range | 0–40 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-501MA |
| Detection Method | Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates: 0.03–20 mg/kg |
| Carbamates | 0.03–20 mg/kg |
| Pyrethroids | 0.10–30 mg/kg |
| Organochlorines | 0.10–10 mg/kg |
| Light Source | 254 nm UV lamp |
| Warm-up Time | ≤5 min |
| Irradiance | ≥1000 µW/cm² |
| Lamp Lifetime | ≥12,000 h |
| Wavelength Repeatability | ±1 nm |
| Wavelength Accuracy | ±5 nm |
| Filter Transmittance | ≥95% |
| Spot Spacing | 5–30 mm |
| Sample Volume | 2.5–15 µL |
| Spot Diameter | ≤2.0 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–85% RH |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Software Platform | Windows XP |
| Detection Modes | Transmission & Reflectance |
| Dimensions | 580 × 360 × 260 mm |
| Weight | 15.8 kg |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1012SD |
| Detection Methods | Enzyme Inhibition Assay, Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates & Carbamates Inhibition Rate: 0–100% |
| Organochlorines | 0.0–40.0 mg/kg |
| Pyrethroids | 0.0–40.0 mg/kg |
| Number of Channels | 12 |
| Measurement Error | ±10% |
| LOD | Organophosphates & Carbamates: 0.01–3.0 mg/kg |
| Organochlorines | 0.3 mg/kg |
| Pyrethroids | 0.3 mg/kg |
| Light Sources | High-brightness LEDs at 405 nm and 254 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Dimensions | 470 × 280 × 180 mm |
| Weight | 3.6 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1 Hz |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1020SD |
| Detection Methods | Enzyme Inhibition, Thin-Layer Chromatography (TLC), Colloidal Gold Immunochromatography |
| Measurement Range | 0.0–100.0% (relative inhibition or signal intensity) |
| Number of Channels | 20 |
| Optical Stability | ±0.005 A/20 min |
| Sensitivity | 0.01–3.0 mg/kg (matrix-dependent) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Display | 10-inch capacitive touchscreen |
| OS | Windows Embedded |
| Data Output | Dual-printing support (integrated thermal printer + external USB/LAN printer) |
| Power | Rechargeable Li-ion battery + AC adapter |
| Portability | Integrated carry case with detachable control unit and field imaging module |
| Brand | OASIS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LZ-7000 |
| Detection Method | Combined Spectrophotometric and Dry-Chemistry Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 36 |
| Measurement Error | ≤5% |
| Limit of Detection (LOD) | 0.01 mg/kg |
| Display | Color capacitive touchscreen |
| Storage | MicroSD (TF) card expandable |
| Connectivity | Wi-Fi, Bluetooth, Ethernet |
| Interfaces | USB 2.0, RJ45 Ethernet, HDMI |
| Power Supply | DC 12 V (adapter included) |
| Battery | Built-in high-capacity rechargeable Li-ion battery |
| Processor | Multi-core 1.8 GHz ARM-based SoC |
| Data Output | Integrated thermal printer + external printer support |
| GPS | Built-in GNSS module for geotagging |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JT-DB10B |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Range | 0.00–1000 ppb |
| Detection Limit (LOD) | 0.01 ppm |
| Accuracy | ±5% |
| Channel Count | 1 |
| Measurement Speed | <2 s per test |
| Display | 5-inch capacitive touchscreen (Android OS) |
| Power Supply | Built-in rechargeable lithium battery |
| Data Output | C/T line intensity, CT ratio, colorimetric quantification |
| Connectivity | Wi-Fi, Bluetooth, USB 2.0 |
| Compliance | Aligns with MOA Notice No. 102 (2022), “Three-Year Action Plan for Residue Control in Edible Agricultural Products”, and Technical Guidance for Cowpea, Leek & Celery Quality Safety Management |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RP410 / RP420 |
| Pricing | Available Upon Request |
| Wavelength Range | 407–413 nm |
| Photometric Accuracy | ±0.5% τ (0–100% τ) |
| Photometric Repeatability | ±0.3% τ |
| Photometric Modes | Transmittance (%τ), Absorbance (A), Relative % (R%) |
| Optical Range | 0–200% τ (−0.301 to 3.000 A) |
| Inhibition Rate Range | −20% to 900% |
| Detection Channels | 8 simultaneous cuvette positions |
| Power Options | AC 220 V / DC 12 V (optional external battery pack) |
| Data Retention | Non-volatile memory with power-loss protection |
| Firmware Update | Local PC-based OTA update via USB interface |
| Network Integration | RS-232 and USB-to-PC communication |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-100C |
| Detection Method | Enzyme Inhibition (Test Strip-Based) |
| Measurement Range | 0–99.9% inhibition rate |
| Detection Limit | 0.05 ppm |
| Accuracy | ±10% |
| Repeatability | ≤5% |
| Channel Count | 1 |
| Display | Color LCD |
| Power Supply | Integrated Lithium Battery (8 h continuous operation) |
| Dimensions | 175 × 100 × 85 mm |
| Connectivity | Bluetooth 4.0 |
| Data Output | Wireless transmission to regulatory platforms & mobile app integration for traceability and certificate generation |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1217C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interfaces | RS-232 and USB |
| Power Supply | 220 V ±10% AC |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CNY-1217D |
| Detection Method | Spectrophotometric Colloidal Gold Immunoassay |
| Measurement Range | 0–100% inhibition |
| Number of Detection Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 10.1-inch color capacitive touchscreen |
| Operating System | Android |
| Data Storage | Internal + microSD expansion (up to 200,000 records) |
| Connectivity | Wi-Fi, optional 3G/4G/5G, GPS/AGPS interface |
| Printing | Thermal label printer (compliant with MOA’s “Edible Agricultural Products Certificate Management Measures”) |
| Optical Performance | Absorbance range 0.000–4.000 A |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1217LS |
| Detection Method | Enzyme Inhibition (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift (3 min) | ≤0.3% |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Interface | RS232 & USB |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218C |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±1.5% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch capacitive touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| OS | Android 7.0, quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage + microSD expansion |
| Connectivity | Dual USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Data Export | Excel (.xlsx) via USB drive |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1218D |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 (expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218DJ |
| Detection Methods | Spectrophotometry & Colloidal Gold Immunochromatography |
| Measurement Range | 0–100% (Relative Inhibition or Signal Intensity) |
| Number of Channels | 12 (Spectrophotometric) + 3 (Colloidal Gold, expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Detection Limit | 0.2 ppm (for representative organophosphates and carbamates) |
| Display | 10.1-inch TFT-LCD touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| Operating System | Android 7.0, Quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage |
| Connectivity | Dual-band Wi-Fi, RJ45 Ethernet, Bluetooth 4.2, optional 3G/4G/5G module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Export | USB 2.0 ×2, Cloud API support for real-time upload and traceability |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218ZF |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (Transmittance) | ±2.0% T |
| Photometric Repeatability (Transmittance) | ≤0.2% T |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| Measurement Accuracy | ±5% |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch Capacitive Touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 4G LTE Module |
| Internal Storage | ≥32 GB |
| Battery | Integrated Rechargeable Li-ion (up to 6 h operation) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-12K |
| Detection Method | Enzyme Inhibition Rate Method |
| Measurement Range | 0–100% |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Temperature Control Range | 30–50 °C ±0.5 °C |
| Preheating Time Setting | 1–99 min |
| Reaction Time Setting | 1–99 min |
| Power Supply | AC 220 V / DC 12 V / Internal Rechargeable Battery (3.6 V / 1400 mAh) |
| Dimensions | 325 × 100 × 40 mm |
| Weight | ~600 g |
| Carrying Case Dimensions | 400 × 290 × 120 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1617C |
| Price | USD 2,500 (FOB Shanghai) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 16 |
| Measurement Error | ≤ ±10% |
| Limit of Detection (LOD) | 0.3 ppm for organophosphates and carbamates |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–99.99% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤ ±2.0% |
| Photometric Repeatability (Transmittance) | ≤ ±0.2% |
| Photocurrent Drift | ≤ ±0.2% (within 3 min) |
| Inhibition Rate Display Range | 0.00–99.99% |
| Inhibition Rate Repeatability | ≤ ±5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interface | USB |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Display | 7-inch color TFT LCD touchscreen with full Chinese GUI |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1618 |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition |
| Number of Channels | 16 |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 5% Inhibition |
| Display | 10.1-inch TFT LCD Touchscreen (1024×600) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±1.5% T |
| Photometric Repeatability | ≤0.2% T |
| Dark Current Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 3G/4G/5G Module, GPS/AGPS |
| Operating System | Android 7.0 (Quad-Core, 1.8 GHz, 2 GB RAM, 16 GB Storage) |
| IP Rating | IP65 (Front Panel) |
| Data Export | Excel via USB or SD card |
| Throughput | Up to 180 samples/hour |