LAND
Filter
Showing all 5 results
| Brand | LAND |
|---|---|
| Origin | UK |
| Model | 4650-PM |
| Measurement Principle | Forward-Scatter Laser Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–15 to 0–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ≤1% |
| Operating Temperature | up to 500 °C (930 °F) |
| Compliance | U.S. EPA Performance Specification 11 (PS-11), applicable to MATS and Boiler MACT requirements |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MillWatch / SiloWatch |
| Pricing | Available Upon Request |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1200B |
| Temperature Range | 150–1150 °C |
| Cavity Diameter | 50 mm |
| Cavity Depth | 400 mm |
| Emissivity | 0.998 |
| Temperature Stability | ±0.2 °C over 60 min |
| Temperature Uniformity | < ±0.15% t across central 40 mm of 50 mm cavity |
| Heating Rate | ~2 h to reach 1000 °C |
| Controller | Eurotherm PID with N-type Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1600B2 |
| Temperature Range | 500–1550 °C |
| Emissivity | 0.998 |
| Stability | ±0.2 °C per 60 min |
| Uniformity | < ±0.15% of setpoint over central 40 mm of 50 mm-diameter cavity |
| Cavity Dimensions | Ø50 mm × 400 mm |
| Temperature Resolution | 1 °C |
| Heating Time | 90 min to 1400 °C |
| Cooling Time | 180 min to 200 °C |
| Ambient Operating Conditions | 10–40 °C |
| Controller | Eurotherm PID with Type R Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VIRALERT 3 |
| Price | Upon Request |
| Spectral Response | 7.5–13.5 µm (typical uncooled microbolometer range) |
| Detector Type | Uncooled VOx Microbolometer |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Ambient-temperature-stabilized thermal imaging |
| Frame Rate | <9 Hz |
| Temperature Accuracy | ±0.5 °C at 1 m distance (±0.9 °F) |
| Temperature Range | 10 °C to 50 °C (ambient operating), 30 °C to 45 °C (human skin temperature measurement range) |
| Thermal Resolution (NETD) | <0.12 °C |
| IR Image Resolution | 1280 × 960 pixels |
| Visual Camera Resolution | 1280 × 960 @ 12 fps (CMOS color sensor) |
| Field of View | 39° × 31° |
| Reference Source | Integrated fixed-point blackbody at 38.0 °C ± 0.2 °C |
| Power Supply | 5 V DC via USB (blackbody), system powered via PC USB or external 12 V DC adapter |
| Compliance | CE, UKCA, RoHS, ISO/IEC 17025 traceable calibration support |