Loobo
Filter
Showing all 24 results
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BG9711A |
| Price | Upon Request |
| Detector | Ø40×37 mm NaI(Tl) Scintillation Crystal |
| Measured Radionuclides | Cs-137, Cs-134 (calibration-compatible with I-125, Co-60, etc.) |
| Detection Limit | 20 Bq/L (relative to Cs-137) |
| Measurement Protocol | 30-min background + 10-min sample |
| Lead Shielding Thickness | 25 mm |
| Display | LCD showing activity or specific activity with uncertainty estimation |
| Background Subtraction | Enabled |
| LED Status Indicators | Green (safe), Yellow (elevated), Red (exceeds regulatory threshold) |
| Operating Temperature | 10–35 °C |
| Operating Humidity | ≤80% RH at 40 °C |
| Primary Power | DC 9 V / 1000 mA adapter |
| Backup Power | Two AA batteries |
| Power Consumption | <200 mW |
| Dimensions (L×W×H) | 190×190×350 mm |
| Net Weight | 26.4 kg |
| Data Storage | 200 measurement records |
| Connectivity | Optional USB interface for PC-based control and data export |
| Compliance | Designed for field-deployable radiological screening per IAEA Safety Guides RS-G-1.8 and national food/water monitoring protocols |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HDR-AC3 |
| Price | USD 1,400 (FOB Qingdao) |
| Resolution | 3840 × 2160 (4K UHD) |
| Sensor | Sony 13 MP High-Sensitivity CMOS |
| Zoom | 30× Intelligent Digital Zoom |
| IR Illumination | Built-in IR LEDs with Auto/Manual Night Mode Switching |
| Display | 3.1″ IPS Touchscreen (180° Rotatable) |
| Battery | 1700 mAh Rechargeable Li-ion (Typical Runtime: 2.5–3.5 h Continuous Recording) |
| Wireless Connectivity | IEEE 802.11 b/g/n Wi-Fi (2.4 GHz), Compatible with iOS/Android Remote Control & Live Streaming |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KS2202 |
| Price | USD 2,800 (FOB Qingdao) |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Online Continuous Analyzer |
| Range | 10–5000 mg/L COD<sub>Cr</sub> |
| Repeatability | ≤3% RSD |
| Accuracy | ±5% of reading (≥100 mg/L) |
| LOD | 15 mg/L |
| Resolution | 1 mg/L |
| Cycle Time | 15 min per analysis |
| Compliance | HJ 377–2019, GB 11914–1989 |
| Auto-Standard Verification | Yes |
| Dual Waste Discharge | Cleaning Solution & Spent Reagent Separately Collected |
| Chloride Tolerance | Up to 35,000 mg/L Cl⁻ (with HgSO₄ masking) |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-108 |
| Instrument Type | Fixed-Mount Thermal Screening Gateway |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Thermal Resolution | ±0.3 °C |
| Measurement Range | 20 °C to 50 °C |
| Detection Distance | 1.5 m to 5 m |
| Throughput Capacity | 150–200 persons/min |
| Blackbody Emissivity | 0.96 ± 0.02 |
| NETD | ≤60 mK (F/1, 300 K, 50 Hz) |
| IR Sensor | Uncooled Microbolometer Array (160 × 120 pixels, 17 µm pitch, 8–14 µm spectral band) |
| Visible Camera | 2 MP CMOS, 6 mm lens, 0.01 Lux (color), SNR > 56 dB |
| Onboard Processing | Broadcom BCM2711 (64-bit quad-core @ 1.5 GHz), VideoCore VI GPU, dual-band Wi-Fi 802.11ac + Gigabit Ethernet |
| Power Input | 5 V/3 A via USB-C |
| Operating Temperature | 0 °C to 40 °C |
| Enclosure | Flame-retardant, waterproof PVC composite (IP54-rated indoor/outdoor use with optional rain canopy) |
| Passage Dimensions | 1900 (H) × 700 (W) × 580 (D) mm |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-1090 |
| Price Range | USD 0–7,200 (FOB Qingdao) |
| Sampling Flow Rate | 0.5–2.0 L/min |
| Flow Accuracy | ≤ ±5% FS |
| Sampling Temperature Range | 100–160 °C (factory-set at 130 °C) |
| Sampling Velocity | 2 m/s |
| Sample Target | Gaseous Elemental and Oxidized Mercury in Flue Gas |
| Probe Length | 1.5 m (standard), customizable |
| Effective Heated Length | 1.2 m (standard), customizable |
| Probe Weight | ~4 kg |
| Minimum Stack Port Diameter | ≥ Φ60 mm |
| Max Operating Temperature (Probe Body) | ≤ 200 °C |
| Material | 6063 Aluminum Alloy Housing (anodized), 316 Stainless Steel Sampling Tube |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-120F(GK) |
| Sampling Flow Rate | 80–120 L/min |
| Maximum Negative Pressure | >26 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | ≥±2.5% |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Time at Max Flow & Max Resistance | 2–8 h with flow deviation ≤±5% |
| Instrument Type | Single-Channel Gas Sampler |
| Compliance | HJ/T 374–2007, HJ 93–2013, HJ 656–2013, HJ 657–2013, HJ 691–2014, HJ 480–2009, JJG 943–2011 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-2 |
| Instrument Type | Flue Gas Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Adjustable Sampling Flow Rate | 0.5–2.0 L/min |
| Pre-Flow Pressure Range | −30 to 0 kPa |
| Pre-Flow Temperature Range | −30 to +99 °C |
| Atmospheric Pressure Measurement Range | 70–130 kPa |
| Data Storage Capacity | 1000 sets |
| Operating Temperature | −30 to +50 °C |
| Dimensions (L×W×H) | 225 × 160 × 280 mm |
| Weight | ~3 kg |
| Power Supply | AC 220 V ±10%, 50 Hz or DC 12 V |
| Power Consumption | <20 W |
| Brand | Loobo |
|---|---|
| Model | LB-6200 |
| Origin | Shandong, China |
| Flow Range | 0–40 m³/s |
| Liquid Level Measurement Error | ≤ 0.5 mm |
| Flow Measurement Accuracy | ≤ ±1% |
| Sampling Frequency | 3 Hz |
| Display | Color TFT Touchscreen |
| Data Storage | 20,000 records |
| Battery Life | 72 h (DC 24 V Li-ion) |
| Operating Temperature | 10–40 °C |
| Operating Humidity | ≤ 85% RH |
| Dimensions | 400 × 300 × 110 mm |
| Weight | 4 kg |
| Interface | USB |
| Compliance | HJ/T 15–2019, HJ 354–2019 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-7220 |
| Instrument Type | Online Continuous Monitor |
| Measurement Principle | Beta-Ray Absorption |
| Measured Parameters | PM₂.₅, PM₁₀, TSP |
| Measurement Range | PM₂.₅: 1–1000 µg/m³ |
| PM₁₀ | 1–10,000 µg/m³ |
| TSP | 0–10 mg/m³ |
| Sampling Flow Rate | 16.7 L/min |
| Detection Limit | 1 µg/m³ |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-7220 |
| Instrument Type | Online Continuous Monitor |
| Measurement Principle | Beta-Ray Absorption (⁴C Source) |
| Measured Parameters | TSP/PM₁₀/PM₂.₅ Mass Concentration, Wind Speed, Wind Direction, Ambient Temperature & Relative Humidity |
| Measurement Range | 0–10,000 µg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Detection Limit | 1 µg/m³ |
| Display Resolution | 0.1 µg/m³ |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 10% RSD |
| Calibration Film Reproducibility | ≤ ±2% |
| Parallelism (inter-unit) | ≤ 15% |
| Sampling Method | Pump-Driven |
| Display | 7.0-inch Industrial Color Touchscreen |
| Dimensions (H×W×D) | 305 × 245 × 389 mm |
| Weight | ≤ 25 kg |
| Operating Humidity | 0–99% RH |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤ 190 W |
| Data Transmission | 4G LTE Wireless |
| Ingress Protection | IP53 |
| Temperature & Humidity Compensation | Integrated DHS (Dry-Humid Stabilization) System |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8000B |
| Instrument Type | Portable Automatic Water Sampler |
| Sampling Method | Quantitative Sampling |
| Single Sample Volume | 200–1000 mL (adjustable) |
| Sampling Volume Accuracy | ±1% |
| Pump Speed Range | 60–300 rpm (bidirectional) |
| Minimum Sampling Interval | 1 minute |
| Maximum Sampling Depth | 10 m |
| Power Supply | AC 220 V ±10%, 50/60 Hz (standard) |
| Power Consumption | <22 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Drive Unit Dimensions | 234 × 144 × 140 mm |
| Drive Unit Weight | 3 kg |
| Enclosure Rating | IP31 |
| Display | 3-digit LED (real-time speed) |
| Control Interface | Rotary pulse encoder |
| Memory Function | Power-loss data retention |
| Motor Type | Hybrid stepper motor |
| Pump Mechanism | High-reliability peristaltic pump |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8101 |
| Rainfall Detection Sensitivity | ≥0.03 mm/min |
| Lid Opening Response Time | ≤30 s |
| Lid Closing Response Time | ≤5 min |
| Measurable Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±1% |
| Collection Funnel Diameter | 300 mm |
| Dust Deposition Cylinder Height | 150 mm |
| Sampling Bucket Capacity | 15 L |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤98% RH |
| Dimensions (L×W×H) | 1200 × 550 × 1000 mm |
| Weight | ~40 kg |
| Power Supply | AC 220 V (±10%), 50 Hz |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-8101 |
| Rain Sensor Sensitivity | ≥0.03 mm/min |
| Lid Opening Time | ≤30 s |
| Lid Closing Time | ≤5 min |
| Measurable Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±1% |
| Precipitation Collector Diameter | 300 mm |
| Dust Deposition Cylinder Height | 150 mm |
| Sampling Bucket Capacity | 15 L |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | ≤98% RH |
| Dimensions (L×W×H) | 1200 × 550 × 1000 mm |
| Weight | ~40 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-FHB08 |
| Price | USD 495 (FOB Qingdao) |
| Compliance | MEP “Guidelines for Standardization of Comprehensive Ecological and Environmental Protection Law Enforcement Equipment (Standard Configuration, 2020 Edition)” |
| Construction | Anodized aluminum frame chassis |
| Configuration Flexibility | Modular slot-based layout for field-customizable PPE integration |
| Transport Form Factor | Dual-option — rugged wheeled trolley case or ergonomic dual-shoulder backpack |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-JC |
| Material Options | Organic Glass / Borosilicate Glass / Ceramic |
| Internal Diameter | 15.0 ± 0.5 cm |
| Height | 30.0 cm |
| Base | Flat and Level |
| Internal Surface | Smooth, Non-Porous, Chemically Inert |
| Compliance | Designed to Fully Conform with HJ 1221–2021 “Determination of Total Dust Fall in Ambient Air — Gravimetric Method” |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-NS2112 |
| Primary Flow Rate | 12–120 L/min (±5% accuracy) |
| Concentration Flow Rate | 1.5–15 L/min (±5% accuracy) |
| Flow Repeatability | ±2% |
| Collection Efficiency | >90% for bioaerosol particles ≥3 µm |
| Cut-off Diameter (Da₅₀) | 1.1 µm at 100 L/min, 0.65 µm at 150 L/min, 0.43 µm at 200 L/min |
| Timer Range | 1 s – 99 h 59 min 59 s |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-Q102HB |
| Instrument Type | Portable |
| Detection Method | ISO 6703-2 / HJ 484–2009 (Isonicotinic Acid–Barbituric Acid Spectrophotometric Method) |
| Measurement Range | 0–1 mg/L CN⁻ |
| LOD | 0.004 mg/L |
| Measurement Time | 15–30 min |
| Accuracy | ±5% |
| Repeatability | ≤±5% |
| Optical Stability | ≤±0.001 A/20 min |
| Light Source | Imported Cold LED (100,000 h lifetime) |
| Cuvette Type | Integrated Digestion–Colorimetric Tube |
| Data Storage | 4,000 records + 96 customizable calibration curves |
| Connectivity | USB, LAN, Bluetooth (optional) |
| Display | Backlit LCD (Chinese/English switchable) |
| Power | Rechargeable 5000 mAh Li-ion battery (5 V, 0.3 W) |
| Dimensions | 240 × 95 × 80 mm |
| Weight | 0.5 kg |
| Operating Temp. | 5–40 °C |
| Operating Humidity | ≤85% RH (non-condensing) |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-QM6 |
| Detection Sensitivity | 1×10⁻¹⁵ mol ATP |
| RLU Range | 0–999,999 RLU |
| Background Noise | ≤2 RLU |
| Detection Limit | 1.0 CFU/mL |
| Assay Time | 10 s |
| Accuracy | ±5% or ±5 RLU |
| Overrange Protection | Tilt-activated interruption |
| Display | 3.5-inch color TFT LCD |
| Data Storage | 10,000 records |
| Connectivity | USB + Bluetooth v5.0 |
| Output Options | Optional Bluetooth thermal printer |
| Power Supply | Rechargeable Li-ion battery (AC travel charger included |
| Battery Life | >10 h |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH |
| Dimensions | 70 × 35 × 190 mm |
| Weight | 300 g |
| Brand | Loobo |
|---|---|
| Model | LB-TR008 |
| Material | AISI 304 Stainless Steel |
| Sampling Depths | 1 m, 1.5 m, 2 m |
| Sample Length per Insertion | 15–20 cm |
| Depth Scale | Marked at 100 mm intervals |
| Weight | 5 kg |
| Configuration | Modular threaded assembly (bit, extension tube, handle) |
| Application | Field-based manual soil core sampling |
| Compliance | Designed for ISO 10381-1 (soil sampling principles), ASTM D1586 (standard penetration test reference geometry), and GLP-aligned sample integrity protocols |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-YWF-01 |
| Hydrocarbon-Free Principle | Ultrasonic Atomization |
| Output Flow Rate | 1 L/min |
| Housing Material | Stainless Steel (SUS304) |
| Water Reservoir Capacity | 4.2 L |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 80 W |
| Dimensions (W×D×H) | 310 × 240 × 300 mm |
| Weight | 8 kg |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZFB05 |
| Pricing | Available Upon Request |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZXF |
| Price Range | USD 1,400–4,200 (FOB) |
| Measurement Principle | Laser Light Scattering |
| Safety Classification | Non-Explosive Atmosphere Rated |
| Measurement Range | 0.001–10 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ≤5% FS |
| Relative Error | ≤±10% |
| Particle Size Selectivity | PM₂.₅, PM₁₀, and TSP (via electronic virtual impactor algorithm) |
| Operating Environment | Temperature –10°C to +50°C |
| Power Supply | Rechargeable Li-ion battery (12 h continuous operation) + AC/DC adapter |
| Communication Interfaces | RS232, RS485 (standard) |
| Data Storage | 100,000 records (timestamped, with real-time clock) |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Dimensions | 400 × 300 × 170 mm |
| Weight | 1.0 kg |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | MD-1 |
| Measurement Principle | Stokes Sedimentation + Beer-Lambert Law |
| Particle Size Range | 0–150 µm |
| Resolution | 0.1 µm |
| Accuracy | ≤5% |
| Relative Error | ≤10% |
| Power Supply | 220 V AC |
| Dimensions | 430 × 285 × 300 mm |
| Weight | 15 kg |
| Data Storage Capacity | 40 particle size distribution profiles |
| Safety Classification | Non-explosion-proof |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | ONG300 |
| Type | Handheld |
| Principle | Pulsed Time-of-Flight Laser Ranging |
| Measurement Range | 0–600 m |
| Accuracy | ±0.3 m |
| Magnification | 7× |
| Objective Lens Diameter | 25 mm |
| Eyepiece Lens Diameter | 16 mm |
| Weight | ~195 g (with batteries) |
| IP Rating | IP54 |
| Operating Temperature | 0–40 °C |
| Laser Safety Class | IEC 60825-1 Class 1 |
| Measurement Modes | Distance, Height, Angle, Speed |
| Angular Range | ±90° |
| Angular Accuracy | <0.3° |
| Speed Measurement Error | ±5 km/h |
| Target Requirements | ≥2 m × 2 m surface area, near-perpendicular incidence, medium reflectivity (e.g., concrete wall), clear atmospheric conditions |