| Brand | ATI |
|---|---|
| Origin | USA |
| Model | TDA-2i |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm |
| Weight | 8.6 kg (host 7.5 kg + probe & accessories 1.1 kg) |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Flow Rate | 28.3 L/min ±10% |
| Detection Range | 0.0001% – 100.0% (aerosol penetration) |
| Sensitivity | ±1% of reading (≥0.01% to 100%) |
| Repeatability | ±0.5% of reading (≥0.01% to 100%) |
| Light Source | Solid-state, low-power, low-heat scattering cavity LED (50,000–100,000 hr lifetime) |
| Aerosol Compatibility | PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin |
| Alarm | Audible + visual flashing on host and iProbe display |
| Data Output | USB interface (standard), thermal printer (optional) |
| Reporting Modes | Continuous, Summary, Monitoring |
| Compliance | NSF/ANSI 49, IEST-RP-CC001, ISO 14644-3, EN 61010-1:2010, EN 61326-1:2006, CE, FCC |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Model | C90Ma |
| Sampling Principle | Reverse-Flow Cyclonic Separation |
| Flow Rate | 16.5 LPM |
| Sample Collection Vessel | 1.5 mL Eppendorf Tubes |
| Power Supply | Rechargeable NiCd Battery (120/240 VAC Charging) |
| Compliance | Designed for GLP-compliant environmental microbiology workflows |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Model | HIRST |
| Sampling Principle | Single-Stage Slit Impaction |
| Flow Rate | 10 L/min (0.35 CFM) |
| Sampling Area | 0.89 m² (radius 53 cm) |
| Sampling Duration | 7 days (or configurable for 24 h) |
| Cut-Off Diameter (D₅₀) | 5.2 µm |
| Drum Linear Speed | 2 mm/h |
| Drive Mechanism | Precision 7-Jewel Clockwork Movement |
| Slit Aperture | 2 mm × 14 mm |
| Tape | Melinex® Transparent Polyester Adhesive Tape (Grade 200) |
| Power Supply | 220–240 V, 50 Hz or 110 V, 60 Hz |
| Optional Battery Operation | 12 V DC |
| Net Weight | 16 kg |
| Gross Weight | 30 kg |
| Packaging Dimensions | 57 × 65 × 65 cm |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Miniature Air Sampler |
| Price | Upon Request |
| Sampling Flow Rate | 10 LPM |
| Slide Dimensions | 76 × 26 mm (3 × 1 in) |
| Cut-Off Diameter (D₅₀) | 2.5 µm |
| Height | 115 mm |
| Diameter | 88 mm |
| Weight | 590 g |
| Power Options | 110 V / 60 Hz, 230 V / 50 Hz, or 700 mAh NiCd rechargeable battery |
| Timer Range | 1–9 min (continuous mode at “0”) |
| Motor | Precision Swiss DC motor with precious-metal brush gear |
| Compliance | Designed for ISO 14644-1 classified environments, compatible with ASTM D6305 and EN 13098 for viable and non-viable particle sampling |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Price | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Stage 1 Cut-Off Size | >10 µm |
| Stage 2 Cut-Off Size | 10–4 µm |
| Stage 3 Cut-Off Size | <4 µm |
| Collection Liquid Volume per Stage | 6 mL |
| Vacuum Hose Port Diameter | 6 mm |
| Dimensions (L×W×H) | 115 × 100 × 145 mm |
| Net Weight | 670 g |
| Brand | Burkard |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PASA/B (Battery) / PASA/M (Mains) |
| Price | Upon Request |
| Sampling Flow Rate | 10–20 LPM |
| Height | 148 mm |
| Collection Efficiency D₅₀ | ~2.56 µm |
| Petri Dish Diameter | 90 mm |
| Overall Diameter | 114 mm |
| Weight | 690 g |
| Power Options | Rechargeable 6 V NiCd (700 mAh), or 110 V / 60 Hz & 240 V / 50 Hz AC adapters |
| Timer Range | 1–9 min (or continuous at “0”) |
| Inlet Configurations | Open Grille Cap or Conical Pre-sterilization Cap |
| Operating Duration (Battery) | 3–4 hours continuous |
| Motor | Swiss-sourced brushed DC gearmotor with precious-metal brushes |
| Brand | Digitel |
|---|---|
| Country of Origin | Switzerland |
| Model | DH-77 |
| Flow Rate Range | 100–1000 L/min (6–60 m³/h) |
| Nominal Operating Flow | 500 L/min |
| Filter Diameter | 150 mm |
| Inlet Pre-separators | DPM10/30/00 (EN 12341 certified), DPM2.5/30/00 (EN 12341 certified), DPM01/30/00 (Duisburg Aerosol Institute specification) |
| Enclosure Rating | IP54 |
| Data Interface | RS-232C, Modem, Wireless Modem, Ethernet |
| Optional Modules | PUF Sampling Unit, Cooling Module (maintains filter storage at 21 °C per EN 12341), Temperature-Controlled Filter Tray |
| MTBF | 36,000 hours |
| Solar Radiation Mitigation | Aerostatic Float Housing |
| Anti-Icing | Intermittent Heating System |
| Brand | Digitel |
|---|---|
| Origin | Switzerland |
| Model | DHA-80 |
| Flow Rate Range | 100–1000 L/min (6–60 m³/h) |
| Nominal Operating Flow | 500 L/min |
| Filter Diameter | 150 mm |
| Filter Carousels | 15 positions |
| Continuous Unattended Operation | Up to 14 days |
| Ingress Protection Rating | IP54 |
| MTBF | 36,000 hours |
| Compliance | EN 12341 (PM₁₀, PM₂.₅), Duisburg Institute Specification (PM₁) |
| Optional Modules | PUF Sampling Unit, Cooling Module (21 °C), Environmental Enclosure with Solar Radiation Shielding |
| Communication Interfaces | RS-232C, Modem, Wireless Modem, Ethernet |
| Brand | Digitel |
|---|---|
| Origin | Switzerland |
| Model | DPA96 |
| Flow Rate Range | 5–50 L/min (0.3–30 m³/h) |
| Certified Inlet | EN 12341-compliant PM₁₀, PM₂.₅, and PM₁ cyclone cut points |
| Flow Control | Enviro-Drive™ precision volumetric regulator (±1% accuracy at 2.3 m³/h) |
| Enclosure Rating | IP50 (lab) / IP54 (field) |
| Interface Options | RS-232, Ethernet |
| Valve Options | DIGITEL 16-way unidirectional valve or 8-port solenoid valve |
| Control | Touchscreen GUI with menu-driven programming |
| Sample Head Compatibility | Interchangeable inlet assemblies for size-selective aerosol fractionation |
| Brand | Digitel |
|---|---|
| Origin | Switzerland |
| Model | DRA-12 |
| Sampling Principle | Precipitation-Triggered Sequential Wet-Deposition Collection |
| Bottle Capacity | 32 × 250 mL PTFE-Coated Polyethylene Vials |
| Bottle Exchange | Automatic, Level-Sensing Actuated |
| Contact Materials | Fully PTFE-encapsulated Wet Path |
| Temperature Control | Integrated Heating/Cooling of Lid, Funnel, and Roof Assembly |
| Environmental Sensors | Radiation-Shielded Ambient Temperature Sensor |
| Control System | Onboard Microprocessor with Real-Time Clock & Programmable Logic |
| Interface | RS-232C, Modem, Wireless Modem Support |
| Compliance Ready | Designed for ISO 9060:2018 (Solar Radiation), ASTM D5475-21 (Atmospheric Deposition Sampling), and EU Directive 2004/107/EC (Heavy Metals in Air) |
| Brand | DINGBLUE |
|---|---|
| Origin | Beijing, China |
| Model | WA-15 |
| Sampling Principle | Liquid Impaction via Tangential Cyclonic Flow |
| Sample Collection Medium | Aqueous Liquid (e.g., PBS, Viral Transport Medium) |
| Compatibility | Standard 15 mL or 50 mL Conical Centrifuge Tubes / Cryovials |
| Operating Temperature Range | −10 °C to 45 °C |
| Weight | < 2.5 kg |
| Power Supply | Rechargeable Li-ion Battery (≥8 h continuous operation) |
| Touchscreen Interface | 5-inch capacitive display with intuitive sampling protocol setup |
| Adjustable Sampling Duration | 1–60 min (1 sec resolution) |
| Cut-off Diameter (50% collection efficiency) | ≤ 0.65 µm (at 120 L/min flow rate) |
| Flow Rate | 100–130 L/min (calibrated, ±2% accuracy) |
| Compliance | Designed per ISO 14698-1:2003 (Biocontamination control), ASTM E2997-15 (Standard Practice for Bioaerosol Sampling), and aligned with CDC/NIOSH bioaerosol sampling guidance |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | GR1352 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2053 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Model | GHK-2054 |
| Flow Rate Control | Microprocessor-regulated constant-flow sampling via integrated mass flow, pressure & temperature sensors |
| Compliance | HJ 1149–2020, HJ 61–2021, HJ 1009–2019 |
| Data Storage | 100 sampling sessions with timestamped environmental and operational parameters |
| Power Failure Recovery | Automatic data retention and resume-on-power restoration |
| Protection Features | Over-flow shutdown (±10% deviation sustained >5 min), thermal & current overload protection |
| Portability | Tripod-mounted compact chassis with adjustable sampling height |
| Data Export | USB flash drive interface for raw parameter logs (flow, T, P, volume, time) |
| Calibration | Digital zero/span adjustment for flow, temperature, pressure, and real-time clock |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | GHK-2054 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JHK-3300 |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 100–400 L/min (adjustable, mass-flow controlled) |
| Display | 7.0-inch wide-temperature high-brightness color touchscreen |
| Data Output | Bluetooth printing + USB flash drive export |
| Sample Collection Medium | Liquid (e.g., sterile saline or buffer) |
| Collection Principle | Cyclonic inertial impaction with dry-wall concentration |
| Data Storage Capacity | >100,000 sampling records |
| Environmental Sensors | Integrated pre-sampler temperature & pressure sensors for standardized volume correction (at 25 °C, 101.325 kPa) |
| Power Backup | Auto-resume sampling after power interruption |
| Compliance | GB/T 39990–2021, JJF 1826–2020, GB/T 38517–2020, GB/T 18204.3–2013, GB/T 18204.5–2013, GB/T 25916.1–2010, GB/T 18883–2022 |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | 4000e |
| Max. Flow Rate | 1000 m³/h (configurable: 200 / 500 / 700 / 1000 m³/h) |
| Operating Temperature Range | −30 °C to +40 °C (optional up to +50 °C) |
| Compliance | EU Directive 2008/50/EC, German 39th BImSchV, ISO 7708, ISO 8756, EN 481, TA Luft |
| Cut-Point Options | TSP, PM₁₀, PM₂.₅, UHVCI (Ultra-High-Volume Cascade Impactor) |
| Filter Compatibility | Glass microfiber, Quartz microfiber, Polyimide (Kapton®), Polycarbonate (PC), Polyester, Polypropylene (PP), PTFE (Teflon®), Polyurethane foam (PU), Polyvinyl fluoride (PVF/Tedlar®) |
| Optional Meteorological Sensors | Wind direction & speed, Relative humidity, Ambient temperature, Precipitation, Solar radiation, UV index, Total radiation, Acoustic noise, Vibration |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | ISAP LPCI |
| Sampling Flow Rates | 5 L/min or 27 L/min |
| Aerodynamic Diameter Cut-Points | 20.0 µm to 1 nm |
| Temperature Range | −50 °C to +310 °C |
| Nozzle Plate Outer Diameter | 60 mm |
| Impaction Plate Inner Diameter | 20 mm |
| Calibration | Traceable, per-stage NIST-traceable impactor calibration |
| Materials | Acid-resistant stainless steel and inert alloys |
| Compliance | Designed for ISO 29463, ISO 14644, ASTM D1738, EPA Method IO-3.3, and EU Directive 2008/50/EC ambient PM monitoring frameworks |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-NS2112 |
| Primary Flow Rate | 12–120 L/min (±5% accuracy) |
| Concentration Flow Rate | 1.5–15 L/min (±5% accuracy) |
| Flow Repeatability | ±2% |
| Collection Efficiency | >90% for bioaerosol particles ≥3 µm |
| Cut-off Diameter (Da₅₀) | 1.1 µm at 100 L/min, 0.65 µm at 150 L/min, 0.43 µm at 200 L/min |
| Timer Range | 1 s – 99 h 59 min 59 s |
| Brand | Tisch |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AirHVS |
| Pricing | Upon Request |
| Flow Rate | 200–1300 L/min |
| Standard Cut-Point Flow | 40 CFM (1.133 m³/min) for TSP, PM₁₀, and PM₂.₅ |
| Operating Temperature Range | –30 °C (with optional low-temp kit) |
| Power Supply | 220 VAC |
| Dimensions (H×L×W) | 120 × 37 × 37 cm |
| Weight | 14 kg |
| Housing | Anodized Aluminum |
| Motor | Three-Stage Magnetic Induction Brushless DC Motor |
| Data Interfaces | RS232, USB |
| Display | High-Resolution Backlit LCD |
| Optional Features | GSM/GPRS Remote Monitoring, RH/Temperature Sensors, PM₂.₅ Retrofit Kit |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Model | TE-20-800 |
| Sampling Flow Rate | 28.3 L/min |
| Aerodynamic Diameter Range | >9.0 µm to <0.3 µm |
| Stage Count | 8 impactor stages + pre-separator |
| Filter Diameter | 81 mm |
| Material | Anodized aluminum alloy body with silicone O-rings |
| Compliance | Meets US EPA, OSHA, ACGIH, and ISO 21501-4 referenced cascade impactor performance criteria |
| Collection Efficiency | High-fidelity inertial impaction with minimized particle bounce and re-entrainment |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | BC 251 |
| Flow Rate | 3.5 L/min |
| Collection Media | 15 mL centrifuge tube + 1.5 mL centrifuge tube + backup filter |
| Particle Separation Standard | ACGIH/ISO 7708 (Inhalable & Thoracic Fractions) |
| Compliance | NIOSH-developed personal sampler |
| Application | Viral aerosol collection (e.g., influenza, SARS-CoV-2) |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TEI |
| Price | Upon Request |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Model | TE-123, TE-323 |
| Compliance | EPA TO-14/TO-15 |
| Flow Rate | 1–300 mL/min |
| Power Options | 240 VAC 50/60 Hz, 12 VDC, Solar Panel, UPS (TE-323), Battery Backup |
| Mounting | 19″ Rack or Desktop w/Rubber Feet |
| Condensate Trap | Integrated |
| Valve Configuration | 3-Way Stainless Steel Valves |
| Channel Capacity | Up to 7 (TE-123), Up to 8 (TE-323, Custom) |
| Display | Backlit LCD (4×20 chars), Touchscreen (TE-123), Siemens PLC Interface (TE-323) |
| Sample Line Purge Pump | High-Flow Integrated |
| Pre-Filter Material | PTFE |
| Pressure Gauge | Stainless Steel Vacuum Gauge |
| Data Logging | Time-Stamped Flow & Volume Integration |
| Enclosure | 304 Stainless Steel Canister Housing |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-20-800 |
| Sampling Flow Rate | 28.3 L/min (optional 60 L/min and 90 L/min) |
| Aerodynamic Diameter Range | >9.0 µm to <0.3 µm |
| Stage Count | 8 |
| Collection Substrate | 81 mm filter or stainless steel plates |
| Pre-separator Cut-point | ≥10.0 µm |
| Compliance | US Federal Reference Method for PM10/PM2.5, EPA/OSHA/ACGIH inhalable & thoracic fraction criteria, ISO 21501-4, ASTM D7251 |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-3000P |
| Flow Rate Range | 15–29 CFM |
| Filter Holder Diameter | 10–11 cm |
| Motor | 7/8 HP, 3-Stage Vacuum Pump |
| Voltage Options | 110 V / 60 Hz (TE-114787) or 220 V / 50 Hz (TE-114789) |
| Flow Measurement | Integrated Rotameter (TE-2000P-2) |
| Runtime Meter | Mechanical Elapsed Time Indicator (TE-5012-6 / TE-5010-6x) |
| Filter Compatibility | GF/C Glass Fiber (e.g., Whatman Polbag TE-10453) |
| Mounting | Optional Tripod (TE-2000P-1) |
| Compliance | Meets Procter & Gamble (P&G) Aerosol Collection Efficiency Standard |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | TE-423 |
| Pricing | Upon Request |
| Channels | 3 |
| Sampling Flow Rate | 1 mL/min to 2 SLPM |
| Power Supply | 118 VAC, 50/60 Hz, 3 A |
| Control Interface | Touchscreen + Front-panel LCD |
| Ozone Scrubber | Temperature-controlled with cumulative runtime timer |
| Mounting | 19-inch rack-mountable or desktop (with rubber feet) |
| Remote Channel Control | Yes |
| Controller Architecture | PLC-based with front-panel operational interface |
| Structural Design | Ruggedized for long-term field deployment and mobile operation |
| Compliance Basis | DRI Standard Method for Carbonyl Collection |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-5170 |
| Flow Rate | 39–60 CFM (1.1–1.7 m³/min) |
| Compliance | EPA 40 CFR Part 50, Appendix B |
| Calibration | Automatic microprocessor-controlled flow calibration |
| Data Logging | Internal SD card (CSV format), 5-minute interval logging of temperature, pressure, and actual flow rate |
| Flow Stability | ±1% of setpoint (maintained via real-time temperature & barometric pressure compensation) |
| Sample Compatibility | Standard EPA-approved 8×10 inch TSP filter holders |
| Power Supply | 120 VAC, 60 Hz |
| Enclosure | NEMA 4X-rated weatherproof cabinet |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070 |
| Flow Rate | 40 CFM (1.13 m³/min) |
| Cut-Point | PM₁₀ (≤10 µm aerodynamic diameter) |
| Filter Format | 8" × 10" (203 mm × 254 mm) |
| Flow Control Options | VFC (TE-10557) or MFC (TE-300-310) |
| Blower Motor | 1 HP, 2-pole vacuum motor |
| Timer | 7-day mechanical timer (TE-5007) or digital timer (TE-302) |
| Pressure Monitoring | 30-inch water manometer (TE-6001) |
| Data Recording | Continuous flow/pressure recorder (TE-5009) |
| Compliance | EPA Reference Method RFPS-0202-141, 40 CFR Part 50 Appendix L |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | SYS-520 |
| Power Supply | 24 V DC (via adapter) |
| Sample Path Options | Position 1, Position 2, or HEPA-filtered Purge |
| Hose Materials | Tygon® silicone (sampling), PVC (purge) |
| Hose Dimensions | Ø 4.7 × Ø 3.4 mm (Tygon-silicone), Ø 6.0 × Ø 4.0 mm (PVC) |
| Communication Interface | 3-pin connector (compatible with LAP 32X) |
| Dimensions (W × H × D) | 160 × 210 × 130 mm |
| Weight | 1.9 kg |
| Application | Dual-point aerosol sampling for fractional filter efficiency testing |