MAYZUM
Filter
Showing all 14 results
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MAY-2001-V |
| Pricing | Upon Request |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAY-2001HPO |
| Price | USD 4,050 (FOB Guangdong) |
| Brand | MAYZUM |
|---|---|
| Model | MAY-2001NC |
| Measurement Principle | Vibrational Density-based Electrochemical Correlation |
| Measured Parameters | Density (g/cm³), Temperature (°C), NaOCl Concentration (% w/w), Baumé (°Bé) |
| Density Range | 0–2.2 g/cm³ |
| Concentration Range | 0.1–114.62% |
| Resolution | 0.001 g/cm³ / 0.1 °C / 0.1% / 0.1 °Bé (standard) |
| Accuracy | ±0.002 g/cm³ / ±0.5% / ±0.5 °Bé (standard) |
| Temp. Compensation | Automatic, 0–80 °C integrated Pt100 sensor |
| Operating Temp. | −20 to +120 °C (process), −20 to +80 °C (ambient) |
| Pressure Rating | ≤20 MPa |
| Enclosure Rating | IP67 |
| Electrical Interface | M12×1.5 (probe), M16×1.5 (controller) |
| Output Options | 4–20 mA analog, RS485/RS232 digital, dual-channel relay alarms |
| Power Supply | 24 V DC |
| Wetted Materials | PTFE flange, Hastelloy C-276 with PTFE lining |
| Explosion Protection | Ex ia IIB T6 Ga (optional) |
| Data Storage | SQLite database, up to 16 GB |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MAY-3002 |
| Price | USD 1,380 (FOB Guangdong) |
| Measurement Principle | Critical Angle Refraction |
| Measured Parameters | Refractive Index (nD), Temperature (°C), Brix (% w/w), and Custom Concentration Scales |
| Brix Range | 0.0–30.0% |
| Refractive Index Range | 1.3200–1.3810 |
| Resolution | 0.1% Brix, 0.0002 nD, 0.1°C |
| Accuracy | ±0.2% Brix, ±0.0003 nD, ±0.2°C |
| Temperature Compensation | Automatic, 0–60°C |
| Process Temperature | 0–80°C |
| Pressure Rating | ≤1 MPa |
| Wetted Materials | 316L Stainless Steel + Optical-Grade Sapphire Prism |
| Enclosure Material | Anodized Aluminum |
| Electrical Supply | DC 24 V / AC 220 V |
| Output Signals | 4–20 mA, RS485/Modbus RTU, Dual Switch Outputs (High/Low Alarm), Optional Wireless Data Transmission Module |
| Display | Integrated 4.3-inch TFT Touch Controller |
| Cable Length | Up to 100 m (customizable) |
| IP Rating | IP67 |
| Weight | ≈2.25 kg |
| Mounting Options | Top-Insert Flange, Wall-Mount Clamp, or Extended Bracket |
| Brand | MAYZUM |
|---|---|
| Model | MAYA203DIV2L |
| Type | Benchtop Solid Density Analyzer for Hydrogen Quantification in Aluminum Melts |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −30 °C to +60 °C |
| Display | Digital LCD |
| Origin | Guangdong, China |
| Manufacturer | MAYZUM (OEM/ODM Capable) |
| Compliance | GB/T 43139–2023, GB/T 5611–2017, ASTM E807 (adapted), ISO 11922 (principles) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MAYB124G |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0.0001–3.0000 g/cm³ (equivalent to 0.1–100% concentration for common aqueous/organic solutions) |
| Maximum Sample Weight Capacity | 120 g |
| Density Resolution | 0.0001 g/cm³ |
| Display | Digital LCD |
| Compliance Standards | GB/T 13531, GB/T 5526, GB/T 5009, ASTM D1298, ASTM D4052, JIS K 0061, ISO 12185 |
| Measurement Principle | Archimedean buoyancy displacement method |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ir100-AC |
| Type | Online NIR Analyzer |
| Wavelength Range | 4-channel NIR |
| Scan Speed | 30 ms |
| Moisture Range | 0.1–70% w/w |
| Resolution | 0.01% |
| Accuracy | ±0.2% (matrix-dependent) |
| Housing Material | SS316L |
| IP Rating | IP65 |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 10–90% RH |
| Power Supply | DC 24 V, 2 A |
| Output Interfaces | TCP/IP, RS485/RS232, Digital Alarm Outputs (2 channels) |
| Probe Cable Length | Standard 5 m (extendable to 100 m) |
| Installation Distance | 250 ± 100 mm (non-contact transmission mode) |
| Weight | ≈9.8 kg |
| Dimensions | 130 × 360 × 160 mm |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw100-AJ |
| Measurement Principle | Microwave Attenuation & Resonance Frequency Shift |
| Moisture Range | 100 ppm – 99.99% (w/w) |
| Resolution | 50 ppm |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (up to 100 m) |
| Operating Temp. | −10 °C to +90 °C (wetted parts rated to 100 °C) |
| Pressure Rating | ≤ 4.0 MPa |
| Wetted Materials | SS316L, Hastelloy C, PTFE, Monel 400 |
| Process Connections | Flanged, threaded, sanitary clamp, non-contact through-glass |
| Output Signals | TCP/IP, RS485/232, dual relay alarms (HI/LO) |
| Enclosure Rating | IP68 |
| Explosion Protection | Ex db IIC T6 Gb |
| Power Supply | 220 V AC, <100 mA |
| Dimensions | 280 × 485 × 590 mm |
| Weight | ≈ 5 kg |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw201 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Certifications | IP67 ingress protection, ATEX/IECEx optional (explosion-proof variants available) |
| Measurement Principle | Continuous-wave microwave transmission & attenuation analysis |
| Measurement Range | 0.1–99.9% moisture content (w/w) |
| Resolution | 0.1% |
| Typical Accuracy | ±0.01–±0.2% (material- and installation-dependent) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Data Logging | Onboard non-volatile memory with timestamped records (≥1 year at 1-min intervals) |
| Process Connection Options | Flanged, sanitary clamp (DIN 11851), NPT threaded, insertion probe, or through-pipe dual-port transmission |
| Housing Material | 316L stainless steel with electropolished finish |
| Operating Temperature | −20 °C to +65 °C ambient |
| Compliance | Meets IEC 61326-1 (EMC), IEC 61000-6-2/6-4, ISO/IEC 17025 traceable calibration support, FDA 21 CFR Part 11 ready (audit trail & electronic signature enabled in software) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MAZ-Ra300-Acr |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Concentration Range | 0.1–99.9% |
| Resolution | 0.01% |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (extendable to 100 m) |
| Operating Temperature | −10 to 130 °C |
| Wetted Materials | Hastelloy C / PTFE / M400 / Non-contact optical path |
| Process Connection Options | Non-contact direct irradiation, immersion flange, sanitary clamp, NPT thread, flow cell |
| Power Supply | 220 V AC, <0.2 A |
| Output Interfaces | TCP/IP, RS-485/232 (digital), dual-channel relay (alarm & limit control) |
| IP Rating (wetted parts) | IP67 |
| Max Pressure Rating | ≤1 MPa |
| Net Weight | ≈5 kg |
| Dimensions | 280 × 485 × 590 mm (L×W×H) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MAZ-Ra300-BSJZ |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ra300-R4 |
| Origin | Guangdong, China |
| Concentration Range | 10 ppm – 99.9% |
| Measurement Temperature | −20 °C to 135 °C |
| Concentration Accuracy | ±10 ppm to ±0.1% (dependent on matrix and calibration) |
| Resolution | 0.01% |
| Sensor Technology | Soft X-ray & Visible Spectroscopy |
| Pressure Rating | ≤1 MPa |
| Environmental Operating Temperature | −10 °C to 130 °C |
| Output Signals | TCP/IP, RS-485/232 (digital), 2-channel relay outputs (high/low limit & fault alarms) |
| Power Supply | 220 V AC, <0.2 A |
| Ingress Protection | IP67 (wetted parts) |
| Display Options | 4.3″ or 8″ embedded touchscreen controller |
| Temperature Compensation | Automatic |
| Channel Capacity | 1–6 configurable detection channels (customizable) |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Sc201 |
| Measurement Principle | Microwave Dielectric Absorption |
| Accuracy | ±0.3% (typical, dependent on matrix) |
| Resolution | 0.1% |
| Operating Temperature (wetted probe) | up to 120 °C |
| Pressure Rating (wetted probe) | up to 4.0 MPa |
| Output Interfaces | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Installation Options | Flanged contact probe or non-contact over-the-pipe configuration |
| Multi-channel Capability | Supports “one master → multiple slave” topology for cost-effective multi-point monitoring |
| Brand | Mayzum |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MZ-Y300 |
| Instrument Category | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Solid Porous Materials |
| Density Range | 0.01–99.999 g/cm³ |
| Maximum Capacity | 300 g |
| Density Resolution | 0.001 g/cm³ |
| Display | Digital LCD |
| Application Scope | Universal Density Testing for Open- and Closed-Cell Porous Polymers |
| Compliance Context | Designed to support ASTM D3574, ISO 845, ISO 1183-1, and GB/T 6343 test protocols |