| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1-FP |
| Pricing | Available Upon Request |
| Detection Principle | Photometric (Colorimetric) Analysis Based on Lambert-Beer Law & Potentiometric Titration |
| Detection Items | Metal Ion Concentration (e.g., Cu²⁺, Ni²⁺, Fe³⁺, Zn²⁺) |
| Analysis Modes | Colorimetric and Potentiometric |
| Analysis Frequency | Once per 20 Minutes |
| RSD | ≤1% (Potentiometric), ≤2% (Colorimetric) |
| Detection Range | 0.01–10 mol/L (as metal ion) |
| Titration Precision | 1 µL (using 20 mL burette) |
| Alarm Indicators | Dual-Color Status Display (Liquid Level, Out-of-Spec Data, Reagent/Consumable Expiry, System Fault) |
| Output Signals | Modbus TCP, RS-232/RS-485, CAN Bus, 4–20 mA Analog Output |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at ≥10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55 / IP65 (achieved when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 V AC, 50–60 Hz, 200 W |
| Brand | BPC Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AMPTS III |
| Price Range | USD 28,000 – 56,000 |
| Application Fields | Environmental Engineering (Wastewater Treatment, Activated Sludge Assessment) |
| Gas Measurement Resolution | 2 mL / 9 mL |
| Gas Flow Rate Range | 0–6000 mL/h |
| Reactor Volume | 500–2000 mL |
| Maximum Number of Reactors per System | 18 |
| Brand | CEA (China Education Goldsource) |
|---|---|
| Model | CEL-GPPCT |
| Max Operating Pressure | 6 MPa (standard), 10 MPa (optional) |
| Max Operating Temperature | 600 °C (standard), 800 °C (optional) |
| Illumination Zone | Dual-side irradiation, 20 mm diameter, sapphire viewport |
| Heating Zones | 3-zone programmable furnace |
| Temperature Uniformity | ±1 °C in active reaction zone |
| Gas Inlets | 3 independent mass flow-controlled channels (100/100/200 mL/min) |
| Liquid Feed | 1 heated liquid line (<200 °C), optional precision metering pump |
| Preheater | Integrated gas preheater (<600 °C, <10 MPa) |
| Optional GC Configuration | Dual-FID + TCD detectors, VICI autosampler valve (temperature-controlled to 200 °C), dual-detector concurrent analysis capability |
| Compliance | Designed for ASTM E2915, ISO 17025-compliant lab environments |
| Brand | Digerui |
|---|---|
| Model | DA18 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price | USD 140 (converted from ¥999 at 1 USD ≈ ¥7.15) |
| Brand | Digerui |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DA18-1 |
| Gas Flow Rate | 0.01–1 L/min (custom ranges available) |
| Reactor Volume | ≥3 L |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | LMIC-600-CH3Br |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Range | 0–100 ppm CH₃Br |
| Resolution | 0.01 ppm (0–100 ppm) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA, 3 relay outputs |
| Environmental Rating | IP66, Exd IIC T6 Gb |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Power Supply | 12–36 VDC |
| Display | 2.5″ color LCD |
| Compliance | GB 15322.1–2019, GB 3836.1/2–2010, CMC certification, EMI/EMC compliant |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 875 SupLab |
| Pricing | Available Upon Request |
| Dimensions (Total System) | 1200 mm (W) × 650 mm (D) × 1750 mm (H) |
| Control Unit | 260 mm (W) × 100 mm (D) × 200 mm (H) |
| Sample Handling Unit | 450 mm (W) × 650 mm (D) × 750 mm (H) |
| Analytical Unit | 650 mm (W) × 500 mm (D) × 1550 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 500 VA |
| Operating Environment | 15–30 °C, RH 45–85 % (max. daily temperature fluctuation ≤5 °C) |
| Touchscreen Interface | 10-inch full-color serial touch panel |
| Standard Configuration | 4 modular detection channels |
| Throughput | ~10 min for simultaneous quantification of up to 4 analytes in a single sample |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Model | PA4011 |
| Measurement Principle | Spectrophotometry |
| Analysis Time | ≤30 s per measurement |
| Sample Channels | 1–3 (configurable) |
| Analytes | Cu²⁺ and/or Fe²⁺/Fe³⁺ in plating baths |
| Detection Method | Absorbance-based quantification using pre-calibrated calibration curves |
| Reagent-Free Operation | Yes |
| Waste Generation | None |
| Display | 7-inch full-color touchscreen |
| Enclosure Dimensions (PA4011, without reagent cabinet) | 300 mm (W) × 170 mm (D) × 400 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz, 100 W |
| Operating Environment | 15–35 °C, RH ≤95% (non-condensing) |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output, TCP/IP Ethernet |
| Operational Modes | Manual, timed cycle, continuous, and external trigger-controlled |
| Data Management | Time-stamped historical storage, categorized query, exportable CSV/Excel |
| Alarm Functions | Concentration limit violation detection with visual/audio alerts and configurable relay outputs |
| Compliance | Designed for GLP-aligned process monitoring |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA4015 |
| Pricing | Available Upon Request |
| Measurable Parameters | Nitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and others |
| Brand | ETI |
|---|---|
| Model | PA4025 |
| Origin | Guangdong, China |
| Type | Online Reaction Analysis System |
| Measurement Principles | Potentiometric Titration, Photometric Detection, Ion-Selective Electrode (ISE), Direct Sensor Measurement (pH, Conductivity, Refractometry) |
| Sample Compatibility | Aqueous acidic/alkaline process streams containing HNO₃, HCl, H₂SO₄, NaOH, Na₂CO₃, NH₃ (free), Cl⁻, F⁻, ClO⁻, S₂O₈²⁻, H₂O₂, PO₄³⁻, NO₃⁻, Cu²⁺, Fe²⁺/³⁺, Ni²⁺, Cr³⁺/⁶⁺, Zn²⁺, Ag⁺, Cd²⁺, Mn²⁺, Co²⁺, Li⁺, SO₄²⁻, CN⁻, EDTA, etc. |
| Cabinet Dimensions | ~620 mm (W) × 550 mm (D) × 1735 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz |
| Operating Environment | 15–35 °C, RH ≤95% (non-condensing) |
| Interface | 15″ color touchscreen (Windows OS) |
| Communication | RS232, RS485, 4–20 mA analog outputs, Ethernet |
| Programmability | Up to 15 customizable analysis workflows |
| Compliance Support | ASTM D129, ISO 9297, USP <731>, EPA Method 300.0, GLP/GMP-ready audit trail logging (via optional software module) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA4030 |
| Price | Upon Request |
| Analyte Range | Nitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and more |
| Dimensions | 620 mm (W) × 550 mm (D) × 1850 mm (H) |
| Power Supply | 198–242 V, 50 Hz ± 0.5 Hz, 350 W |
| Operating Environment | 15–30 °C, RH 65 % ± 20 % (max. daily temp. swing ≤5 °C) |
| Display | 12-inch full-color touchscreen (serial interface) |
| Communication | RS485 or TCP/IP |
| Detection Methods | Potentiometric Titration, Photometric Titration, Direct Electrode Measurement (pH, Conductivity, Refractometry), Ion-Selective Electrode (ISE) with Standard Addition, UV-Vis Absorbance-based Quantification |
| Workflow Modes | Manual, Scheduled, Continuous, Triggered |
| Data Management | Audit-trail-enabled logging, QC flagging, concentration limit alerts, reagent level monitoring, sample absence detection, leak detection |
| Cabinet Type | Freestanding floor-mounted enclosure |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA5030 |
| Price | Upon Request |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Sample Throughput | Up to 12 sample positions (configurable) |
| Elemental Range | Z = 14 (Si) to 92 (U) |
| Analysis Time per Sample | ≤ 300 s |
| Detection Geometry | Fixed vertical beam path with automated sample positioning |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 100 W |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 45–85 % RH (non-condensing) |
| Enclosure Dimensions | Approx. 800 mm (W) × 820 mm (D) × 1710 mm (H) |
| User Interface | 15″ capacitive touch display running Windows 10 IoT Enterprise |
| Communication Protocols | RS-485 (Modbus RTU), TCP/IP (Ethernet), OPC UA optional |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4, ISO 21043 (XRF performance verification guidelines), ASTM E1621–22 (Standard Guide for XRF Analysis of Ceramic Whiteware) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PA5080 |
| Pricing | Upon Request |
| Application Domain | Electroplating Process Monitoring in Electronics, Semiconductor Fabrication, and Metal Surface Finishing |
| Electrode Configuration | Three-Electrode System (Platinum Rotating Disk Working Electrode, 5 mm diameter |
| Temperature Control | Full-System & Flow-Path Thermal Regulation (±0.2 °C stability) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz, 1000 W |
| Ambient Operating Range | 15–35 °C |
| Human-Machine Interface | 15-inch Full-Color Touchscreen (Windows OS) |
| Cabinet Dimensions | Approx. 650 mm (W) × 750 mm (D) × 1750 mm (H) |
| Measurement Principle | Cyclic Voltammetric Stripping (CVS) with Potentiodynamic Scanning and Faradaic Current Integration |
| Automation Capability | Integrated Reagent Dosing Control for Organic Additive Correction Based on Real-Time Analytical Deviation |
| Software Compliance | Audit Trail, User Access Levels, Electronic Signature Support (FDA 21 CFR Part 11 Ready) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster |
| Type | Turnkey Laser Imaging System for Quantitative Fluid Mixing & Thermal Flow Analysis |
| Imaging Modalities | Planar Laser-Induced Fluorescence (LIF), Rayleigh Scattering, Raman Scattering |
| Measurement Outputs | Instantaneous 2D/3D concentration fields, temperature fields, pH distribution, reactive mixing degree, gas density maps |
| Spatial Resolution | µm-to-mm scale (application-dependent) |
| Temporal Resolution | Up to kHz frame rates (camera- and laser-pulse-limited) |
| Calibration | Traceable hardware and signal calibration per ISO/IEC 17025 principles |
| Software Platform | DaVis v10+ with real-time acquisition, multi-parameter synchronization, and GLP-compliant data logging |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180a |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180C |
| Price Range | USD 112,000–252,000 (FOB Guangzhou) |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 3,000 W |
| Dimensions (W×D×H) | 3600 × 810 × 1930 mm |
| Weight | 1,100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBDA-180I |
| Price Range | USD 112,000 – 252,000 |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Reactors per System | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Air Supply Pressure | 0.2–0.8 MPa |
| Test Chamber Count | 18 |
| Chamber Volume | 3.5 L |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180K |
| Price Range | USD 112,000 – 252,000 (based on EUR/USD exchange rate and typical export pricing) |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 3,000 W |
| Dimensions (W×D×H) | 3600 × 810 × 1930 mm |
| Weight | 1,100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Equipment Co., Ltd. |
| Model | GBDA-180L |
| Measurement Resolution | ±0.01 g |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Reactors per System | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Test Chamber Count | 18 |
| Chamber Volume | 3.5 L |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180S |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3.5 L |
| Maximum Number of Reactors per System | 12 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Air Supply Pressure | 0.2–0.8 MPa |
| Gas Inlet Port | φ8 mm |
| Number of Test Chambers | 18 |
| Overall Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180W |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Mass Resolution | ±0.01 g |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Range | Ambient to 80 °C (0.1 °C increment) |
| Temperature Control Accuracy | ≤ ±0.2 °C |
| Mass Detection Range | 0–4200 g |
| Power Supply | 200 V AC, 50/60 Hz |
| Max. Power Consumption | 3 kW |
| Dimensions (W×D×H) | 2700 × 560 × 1800 mm |
| Operating Environment | 5–40 °C, <60% RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBW-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–100 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Flow Control Range | 0.01–10 L/min |
| Flow Control Accuracy | ±1.0% FS |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Reactor Volume per Chamber | 3 L |
| Max. Number of Simultaneous Reactors | 18 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HK-5300 |
| Configuration Options | Single-Pump-Single-Tank, Dual-Pump-Single-Tank, Triple-Pump-Dual-Tank, Quad-Pump-Dual-Tank |
| Solution Tank Capacity | 0.5–1.5 m³ |
| Dosing Pump Power Options | 0.37 / 0.55 / 0.75 / 1.5 kW |
| Max Dosing Flow Rate | 160 L/h |
| Max Discharge Pressure | 16.0 MPa |
| Control Modes | Automatic (PID + Fuzzy Logic), Manual, Soft-Manual |
| Safety Features | Low-Low Level Pump Shutdown, Pressure Relief Valve, Phase Loss & Overcurrent Protection |
| Output Signal | 4–20 mA Level Feedback |
| Compliance | Designed for IEC 61508 SIL 2-capable integration, compatible with DCS/SCADA systems per IEC 62443 cybersecurity guidelines |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Boric Acid Online Analyzer |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Hydrogen Peroxide Online Concentration Analyzer |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ALT Online Acid Concentration Analyzer for Etchant Solutions |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Model | ALT Online Alkalinity Analyzer for Na₂CO₃ and NaOH Excess in Brine |
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Industrial Online Potentiometric and Photometric Titration System |
| Compliance | Designed for continuous process monitoring per ISO 9001-manufactured quality system |
| Interface | RS232, TCP/IP, Modbus RTU/TCP |
| Display | 7-inch full-color TFT touchscreen (Chinese UI) |
| Processor | ARM Cortex-A8 |
| Detection Modes | Potentiometric (pH, redox), photometric (colorimetric endpoint), complexometric, precipitation, non-aqueous titration |
| Electrode Options | Dual-platinum indicator electrode, combination pH electrode (optional), ion-selective electrodes (customizable) |
| Fluid Handling | High-precision burette (±0.1% volumetric accuracy), electromagnetic switching valves, solvent-resistant peristaltic pumps (≥50,000 cycles lifespan) |
| Sample Throughput | Up to 6 analyses/hour (configurable cycle time) |
| Data Output | Structured CSV/JSON via Ethernet |
| Environmental Rating | IP65 enclosure (industrial cabinet) |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT Online Analyzer for Ammonium Bicarbonate and Organic Amines |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Online Copper Sulfate and Nickel Ion Analyzer for Electroplating Lines |
| Pricing | Available Upon Request |