METTLER TOLEDO
Filter
Showing 301–330 of 403 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD50 |
| Measurement Parameters | pH, mV (ORP), ref mV, Ion Concentration (pX, mol/L, mmol/L, mg/L, ppm, %), Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Ion Concentration Range | 0 to 999,999 (unit-dependent) |
| pH Resolution | 0.001/0.01/0.1 (selectable) |
| mV Resolution | 0.1 / 1 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.002 |
| mV Accuracy | ±0.1 (–500.0 to 500.0 mV) or ±0.2 (–2000.0 to 2000.0 mV) |
| Ion Accuracy | ±0.5% of reading |
| pX Accuracy | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point, auto-buffer recognition, 11 built-in buffer sets + 10 customizable sets |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Japanese) |
| Data Storage | 2000 GLP-compliant records with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB (U-disk export), PC software integration |
| Enclosure Rating | IP54 |
| User Management | Dual-level access control |
| Touchscreen | 7-inch full-color capacitive display with glove-mode support |
| Accessories Included | InLab Expert Pro-ISM electrode, EasyMix™ electrode stand, buffer pouches, protective cover, corrosion-resistant interface housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV, Ion Concentration, Conductivity, Resistivity, TDS, Salinity, Dissolved Oxygen (Polarographic & Optical), Temperature |
| pH Range | -2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.002 |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 / 1 |
| mV Accuracy | ±0.1 mV |
| Temperature Range | -30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Dissolved Oxygen (Polarographic) | 0.000–50 mg/L, ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Dissolved Oxygen (Optical) | 0.000–99 mg/L, ±0.5% |
| Ion Concentration Range | 0–999999 mg/L or ppm |
| Ion Accuracy | ±0.5% |
| Salinity Range | 0.01–80.0 psu |
| Salinity Accuracy | ±0.5% |
| TDS Range | 0.001–1000 g/L |
| Modular Architecture | Four interchangeable measurement modules (S400 pH/mV, S500 pH/Ion, S700 Conductivity, S600/S900 DO), Three independent measurement channels |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Range | S400 (pH/mV/ISFET), S470 (pH/mV/ISFET + Conductivity/TDS/Salinity/Resistivity/Conductivity Ash), S500 (pH/mV/Ion Concentration), S700 (Conductivity/TDS/Salinity/Resistivity/Conductivity Ash) |
| Measurement Range | –2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| mV Range | –2000.0 to +2000.0 mV |
| mV Resolution | 0.1 / 1 mV |
| mV Accuracy | ±0.1 mV |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Temperature Range (ATC/MTC) | –30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 20,000 data points, 250 analytical result sets |
| Compliance | GLP-compliant data handling, ISO/IEC 17025-ready workflows, supports 21 CFR Part 11 audit trails via LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | S230 / S400 / S500 / S700 |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Resistivity Range | 0.01 to 100.0 MΩ·cm |
| TDS Range | 0.001 mg/L to 1000 g/L |
| Salinity Range | 0.00 to 80.00 PSU or ppt |
| Display | 7-inch capacitive color touchscreen |
| Connectivity | USB, RS232, Ethernet |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software configuration) |
| Calibration Support | Manual and automated (with Rondolino autosampler) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Variants | S400 / S470 / S700 / S600 / S900 |
| Measurement Range | pH: –2.000 to 20.000 |
| mV | –2000 to +2000 |
| Resolution | pH: 0.001 |
| mV | 0.1 |
| Accuracy | ±0.002 pH (model-dependent) |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Module Configuration | Up to three interchangeable measurement modules (pH, conductivity, ion concentration, redox, dissolved oxygen) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SevenGo Duo |
| IP Rating | IP67 |
| Compliance | GLP-compliant data management |
| Communication | Infrared (IR) interface |
| Channel Configuration | Dual-channel simultaneous measurement |
| Measurement Modes | pH/mV/Ion Concentration, Conductivity/TDS/Salinity/Resistivity, Dissolved Oxygen (DO) |
| Display Language Support | Multilingual (including full Chinese UI) |
| Electrode Technology | ISM® Intelligent Sensor Management |
| Regulatory Alignment | Designed for ISO/IEC 17025 and FDA 21 CFR Part 11–ready environments (audit trail & user authentication enabled via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SevenGo Duo Pro (pH/FiveGo Dual-Channel) |
| Protection Rating | IP67 |
| Compliance | GLP-supported |
| Connectivity | Infrared (IR) interface for PC/printer data transfer |
| Display | Backlit high-contrast LCD |
| Data Storage | Internal memory with timestamped records |
| Ergonomic Design | Handheld, field-optimized form factor |
| Channel Configuration | Dual-channel simultaneous measurement |
| Certifications | CE, RoHS, compliant with ISO/IEC 17025 laboratory practice guidelines |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | SG (pH/mV), FE (Conductivity), FG (Ion Concentration), EL (Dissolved Oxygen) |
| Instrument Type | Portable Electrochemical Analyzer |
| Compliance | ISO/IEC 17025-ready, GLP/GMP traceable data handling, IP67-rated housing |
| Software Integration | LabX direct pH (PC-based data export to Excel, CSV, PDF) |
| Electrode Interface | SmartSensor™ digital recognition & auto-configuration |
| Calibration Modes | Up to 5-point pH, up to 3-point conductivity (Kcell auto-recognition), 2-point DO (zero/saturation), multi-point ion calibration |
| Data Storage | Internal memory for ≥2000 measurement records with timestamp, operator ID, electrode ID, and environmental conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SG9 |
| Instrument Type | Laboratory-Portable |
| IP Rating | IP67 |
| Measurement Principle | Optical Luminescence (RDO® Technology) |
| DO Range | 0.00–80.00 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–80 mg/L) |
| Saturation Range | 0.0–50.0% |
| Saturation Resolution | 0.1% |
| Barometric Pressure Range | 500–1100 mbar |
| Pressure Resolution | 0.1 mbar |
| Data Storage | 500 GLP-compliant records |
| Calibration Management | ISM® Intelligent Sensor Management |
| Sensor Interface | Digital ISM-enabled OptiOx probe |
| Communication | Infrared (IR) interface |
| Operating Modes | Standard / Expert |
| Endpoint Options | Auto, Manual, Timed |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | SevenGo Series |
| Portability | Handheld / Field-Deployable |
| IP Rating | IP67 |
| Display | Backlit LCD (Professional Models) |
| Connectivity | Infrared (IR) Interface (Professional Models) |
| Data Management | Onboard Storage + PC Export via ErGo Assistant Software |
| Form Factor | Modular Electrochemical Meter Platform |
| Compliance | Designed for ASTM D1293, ISO 7888, ISO 5814, USP <645>, and EPA Method 120.1 / 120.2 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F40K |
| Instrument Type | Multifunctional Benchtop Electrochemical Analyzer |
| Parameter Types | pH, mV, rel. mV, Temperature (ATC/MTC), ISE (with optional module) |
| pH Range | -2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 selectable |
| pH Accuracy | ±0.001 |
| mV Range | -1999.9 to +1999.9 mV |
| mV Accuracy | ±0.1 mV |
| Temperature Compensation | Automatic (-5 to 130 °C) and Manual (-30 to 130 °C) |
| Calibration | Up to 9-point, auto-buffer recognition, 5 pre-programmed buffer sets + 1 user-defined set |
| GLP Compliance | Full audit trail, timestamped calibration & measurement records, user management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | S40 |
| Measurement Parameters | pH (-2.000 to 19.999), mV/ORP (-1999 to +1999 mV), Conductivity (range dependent on sensor), Ion Concentration (with ion-selective electrodes) |
| pH Accuracy | ±0.002 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 selectable |
| mV Accuracy | ±0.1 mV |
| Temperature Range | -30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Display | Backlit LCD |
| Data Storage | Up to 1000 GLP-compliant measurement records and 400 GLP-compliant calibration records |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready with LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Signature/Profile |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SQC-XP Software Application |
| Pricing | Available Upon Request |
| Compatibility | All XP Series Balances (Readability from 1 µg to 64 kg) |
| Sample Management Capacity | Up to 100 Samples |
| Tolerance Systems | EU Regulatory Standards (e.g., Food & Cosmetics), European Pharmacopoeia (Pharma), Three Customizable Tolerance Sets, Dual-Regulatory Compliance Mode |
| Interface | Native Integration with XP Balance Color Touchscreen |
| Data Capture | Fully Automated, Audit-Trail Enabled |
| Training | Unified Workflow Across XP Platform |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / –26.0 to 40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Endpoint Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T50 / T70 / T90 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 to +2000 mV |
| Titration Resolution | 0.1 mV |
| Electrode Interfaces | pH/mV, Conductivity, Coulometric (modular) |
| Built-in Titration Drivers | 1 internal + up to 7 external (T90) |
| Sample Capacity per Series | up to 300 samples |
| Method Storage Capacity | 100 methods |
| Communication Interfaces | Ethernet, USB Host (3×), USB Client (1×), RS-232 (COM, 3–5 ports), CAN Bus (optional) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T7 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | ±2000 mV / –26.0 to 40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Integrated Burettes | 1 internal + 7 external |
| Parallel Titration Capability | Yes (up to 30 tasks, max 8 concurrent) |
| GLP Compliance | Yes |
| Software Logic | IF…THEN conditional method control |
| Supported Techniques | Acid-base, redox, complexometric, non-aqueous, photometric, coulometric & volumetric Karl Fischer titration |
| Auto-sampler Compatibility | InMotion™, Rondolino, Stromboli |
| Sensor Interfaces | Up to 3 sensor boards, plug-and-play sensors |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| User Profiles | Password-protected, role-based access control |
| Connectivity | USB (printer, barcode scanner), RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Tablex2 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |