METTLER TOLEDO
Filter
Showing 61–90 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Type | Ion-Selective Electrode (ISE) Analyzer for Sodium (Na⁺) |
| Measurement Principle | Standard Addition Method with Solid-State Sodium ISE |
| Compliance | Designed to support compliance with GB 28050–2011, FDA 21 CFR Part 11 (when used with validated EasyDirect™ configuration), ISO/IEC 17025 laboratory practices |
| Software | EasyDirect™ Data Acquisition Software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy R40/Brix/Bev |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, active heating & cooling |
| Display | Digital LCD |
| Refractive Index Range | 1.3200–1.5800 nD |
| Built-in Performance Verification | SimpleCheck™ certified reference standards |
| Compliance | Designed for GLP/GMP environments with audit-ready verification workflow |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.30–1.72 |
| Measurement Accuracy | ±0.0001 |
| Resolution | 0.0001 |
| Brix Range | 0–100% w/w |
| Brix Accuracy | ±0.05 (at ~10–80% w/w) |
| Temperature Range | 10–65 °C |
| Temp. Accuracy | ±0.1 °C |
| Supported Units | nD, % Brix, °Oechsle, °Babo, HFCS-42/55, Invert Sugar, Custom Concentration Tables, Freeze Point Depression |
| Preloaded Methods | Up to 66 |
| Auto Sample Detection (FastStart™) | Yes (on Easy Brix & EaSy R4O) |
| Minimum Sample Volume | 0.2 mL (Easy Brix), ~50 µL (EaSy R4O), 0.2 mL (Easy Bev) |
| Dimensions (W×H×D) | 170×156×273 mm (Easy Brix), 198×382×200 mm (EaSy R4O), 170×156×273 mm (Easy Bev) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Easy UV |
| Price | Upon Request |
| Wavelength Range | 190–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light (KCl, 198 nm) | ≤2.5% |
| Light Source | Xenon Flash Lamp |
| Optical Path Lengths | 10 mm, 16 mm, 20 mm, 30 mm, 40 mm, 50 mm (1 inch equivalent) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H×W×D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| Max. Stored Methods | 80 |
| User-Defined Quick Keys | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Colorimetric Standards | CIELAB, APHA, Gardner (30 pre-programmed color scales) |
| Compliance | Designed to support pharmacopeial workflows (USP <85>, EP 2.2.25, JP 2.04) |
| Connectivity | USB port for printer (USB-P25), barcode scanner (SQKitReader™), and peripheral storage |
| Sample Handling | Fixed cuvette holder (no autosampler or cuvette changer) |
| Application Scope | Quantitative analysis, spectral scanning, water quality testing (Spectroquant® integration), color measurement |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy VIS |
| Wavelength Range | 330–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Path Options | 10, 16, 20, 30, 40, 50 mm (1 inch) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H × W × D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| User-Defined Methods | Up to 80 |
| Quick Access Keys per User | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Barcode Reader Compatibility | SQKitReader™ handheld scanner (optional) |
| Printer Interface | USB-P25 |
| USB Host Port | Yes |
| Cuvette Changer | Not integrated |
| Pharmacopeia Compliance | Not specified |
| Colorimetric Standards | 25 pre-programmed methods (CIELAB, APHA, Gardner, etc.) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pipette Management Software & Hardware Platform |
| Model | EasyDirect |
| Automation Level | Semi-Automated Asset Tracking System |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail enabled, 21 CFR Part 11 compliant (with optional electronic signature module) |
| Deployment | On-premise or networked server installation |
| Integration | Compatible with METTLER TOLEDO pipettes (e.g., E4–XLS+, Rainin XLS+), third-party pipettes via manual entry or CSV import |
| User Roles | Admin, Technician, Lab Manager, QA Auditor |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyDirect™ |
| Interface Support | RS232, USB, Ethernet |
| Maximum Instrument Connectivity | 3–10 units depending on module |
| Regulatory Alignment | Designed for GLP/GMP-compliant environments with audit trail readiness |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax 102 LT/ULT |
| Temperature Range | −90 °C to 150 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume per Vessel | 8–100 mL |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Real-Time Data Acquisition | Yes |
| Software Platform | iControl 6.1 |
| Low-Temperature Observation Capability | Yes (frost-free reactor wall down to −80 °C) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax 102/402 HFCal / OptiMax HFCal |
| Principle | Heat-Flow Calorimetry |
| Temperature Range | −20 to 180 °C (configurable) |
| Pressure Rating | Up to 20 bar (g) |
| Reactor Volume | 10–400 mL |
| Thermal Sensitivity | < ±0.5 W |
| Data Acquisition Rate | Up to 10 Hz |
| Compliance | ASTM E698, ISO 11358, USP <1031>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax/Optimax |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume Capacity | 8 mL to 1000 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax™ 102 HFCal |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessel Capacity | 8–1000 mL |
| Number of Reaction Units | 1–10 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | ET08 |
| Moisture Range | 1 ppm – 100% (w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Resolution | 1/2000 of full stroke |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET18 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Measurement Range | 1–14 |
| pH Meter Accuracy | ±0.2 |
| pH Resolution | 0.01 |
| Burette Precision | ±0.3% (v/v) |
| Compliance | Designed for GLP-compliant routine titration workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET28 |
| pH Range | 1–14 |
| pH Accuracy | ±0.2% of full scale |
| pH Resolution | 0.01 |
| Titration Precision | ±0.3% RSD |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Electrode Configuration | Integrated Ag/AgCl composite ring electrode |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET38 |
| pH Measurement Range | 1–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.2% of full scale |
| Titration Precision | ±0.3 µL per dispensing step |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Software Interface | iTitrate method-guided setup engine |
| Data Output | USB and RS232 connectivity for printer (e.g., USB-P25) and PC-based EasyDirect™ software integration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET58 |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Measurement Range | ±2000 mV / (0–14) pH |
| Electrode Input Resolution | ±0.1 mV |
| Polarization Current Source | (0–5) µA, Resolution: ±0.1 µA |
| Temperature Input Range | (0–100) °C, Resolution: ±0.1 °C |
| Repeatability | 0.5% RSD |
| Dimensions (W×D×H) | 170 × 220 × 350 mm, Weight: 1.9 kg (unit only) |
| Display | 4.3″ color touchscreen (480 × 272 pixels RGB) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 V AC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Price Range | USD 700 – 7,000 (FOB) |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 hours |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 h |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasySampler 1210 |
| Temperature Range | –20 °C to 140 °C |
| Sample Type Compatibility | Homogeneous, heterogeneous, slurry, air- and moisture-sensitive, exothermic/hazardous reactions |
| Compliance | Designed for GLP/GMP-aligned workflows, supports 21 CFR Part 11–compliant data integrity when integrated with iC Software Suite |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer 400 |
| Instrument Type | In-line Dynamic Imaging System |
| Number of Lenses | 1 |
| Field of View | 1100 µm × 800 µm (±50 µm) |
| Image Resolution | 2200 × 1700 pixels |
| Sample Dispersion Method | In-situ liquid-phase flow-through measurement |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer |
| Pricing | Upon Request |
| Viewing Field | 1 mm × 1 mm |
| Resolution Accuracy | 1.5 µm |
| Fiber Optic Cable Length | 3 m (standard), 13 m (with USB extender) |
| Weight | 0.66 kg (probe + fiber assembly) |
| Probe Operating Temperature | −20 °C to 135 °C |
| Maximum Pressure Rating | 0–10 bar |
| Probe Housing Material | Hastelloy C-22 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyViewer100 |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 1.5 µm – 1 mm |
| Sample Dispersion Method | In-line liquid-phase measurement |
| Image Resolution | 1.5 µm |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ErgoClips |
| Type | Modular Weighing Accessories Kit for Analytical and Precision Balances |
| Compliance | Designed for use with METTLER TOLEDO X, XS, XP, and Excellence Series balances |
| Includes | ErgoClip Round Bottom Flask, ErgoClip Basket Small, ErgoClip Weighing Boat, MinWeigh Door, ErgoClip Flask (volumetric), ErgoClip Tube, ErgoClip Titration Basket, MinWeigh Door micro, ErgoClips Stand, ErgoClips Stand micro, ErgoClip Small Flask, ErgoClip Filter Holder, ErgoClips Solution Kit, ErgoClips Solution Kit micro, ErgoClip Quantos & Vial Adapters, ErgoClip Basket micro, ErgoClip Flask micro (with extension) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET Series (ET08/ET12/ET15/ET18/ET28/ET38/ET58) |
| Type | Benchtop Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Interface | EasyDirect™ (PC-based), iTitrat™ intelligent calculation engine |
| Titration Drive Resolution | 12,000 steps per full stroke |
| Display | Capacitive touchscreen interface |
| Liquid Handling | Motorized burette with programmable dosing modes (fixed-volume dispensing, manual titration assist, auto-titration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET08 |
| Instrument Type | Coulometric & Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 100 ppm – 100% (w/w) |
| Voltage Input Range | 0–2000 mV |
| Polarization Current Resolution | ±0.1 µA |
| Minimum Detectable Water Content | 100 ppm |
| Dimensions (W×D×H) | 170 × 220 × 350 mm |
| Weight | 1.9 kg (instrument only), +0.8 kg (magnetic stirrer base) |
| Display | 4.3-inch RGB touchscreen (480 × 272 pixels) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 VAC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured globally per ISO 9001-certified facilities) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Automation | Fully integrated InMotion™ KF Autosampler with programmable heating oven (50–250 °C) |
| Sample Capacity | 26 positions on 25 cm footprint |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready with 21 CFR Part 11 audit trail capability |
| Data Management | Built-in One Click™ workflow automation, METTLER TOLEDO LabX® software compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 200 mg H₂O |
| Detection Limit | ≤ 0.1 µg H₂O |
| Electrode Recognition | Integrated Smart Chip Interface |
| Cell Design | Modular Two-Part Coulometric Titration Vessel |
| Optional Accessories | Amber Cell, Thermostatted Cell, InMotion KF Oven Integration |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP Data Integrity Ready |