NCS
Filter
Showing 1–30 of 36 results
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Floor-standing |
| Instrument Category | Scanning-type |
| X-ray Tube Power | 4 kW |
| Analyzable Elements | B to U |
| Beryllium Window Thickness | 75 μm (optional ≤75 μm variants) |
| Goniometer Angular Reproducibility | θ–2θ independent drive |
| Scan Ranges | SC (1–118°), PC (10–148°) |
| Step Angles | 0.001°, 0.002°, 0.005°, 0.01°, 0.02°, 0.05°, 0.1° |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS3500 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (18 MHz, 2.7 kVA) |
| Carbon Range | Low-C: 0.6 ppm–0.1 % |
| High-C | 0.1 %–50 % |
| Sulfur Range | Low-S: 0.6 ppm–0.3 % |
| High-S | 0.3 %–30 % |
| Sensitivity | 0.01 ppm |
| Precision | C: ±1 ppm or RSD < 0.5 % |
| S | ±1 ppm or RSD ≤ 1.0 % |
| Analysis Time | 30–40 s |
| Detector | Imported Pyroelectric Solid-State IR Detector (Germany) |
| Optical Source | Imported IR Source (USA) |
| Gas Flow Control | Micro-Pressure Differential Electronic Mass Flow Control |
| Catalytic Conversion | CuO Oxidation Furnace (optional), SO₂-to-SO₃ Conversion with SO₃ Trap |
| Software Platform | Windows 10/11 Native GUI with LIMS Integration Support |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS Jiangsu Testing Technology Institute Co., Ltd. |
| Model | CS3500G |
| Measurement Principle | Infrared Absorption |
| Combustion Systems | High-Frequency Induction Furnace (18 MHz, 2.7 kVA) & Tube-Type Resistance Furnace (up to 1550 °C, max. 20 A) |
| Carbon Range | HF furnace — low C: 0.6 ppm–0.1 wt% |
| high C | 0.1–50 wt% |
| Sulfur Range | HF furnace — low S: 0.6 ppm–0.3 wt% |
| high S | 0.3–30 wt% |
| Resistance furnace — C | 0.01–100 wt%, S: 0.005–100 wt% |
| Sensitivity | 0.01 ppm |
| Precision | Low-C: ±1 ppm or RSD ≤1% |
| High-C | RSD ≤0.5% |
| Analysis Time | HF furnace — 30–40 s |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS4600 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Vertical Tube Resistance Furnace (Max. 1500 °C, 1 °C Adjustable) |
| Carbon Range | 0.01–100 wt% |
| Sulfur Range | 0.005–100 wt% |
| Sensitivity | 0.1 ppm |
| Precision | C: RSD ≤ 0.5% |
| S | RSD ≤ 1.0% |
| Analysis Time | 60–180 s (user-configurable) |
| Sample Mass | 200–500 mg (coal, typical) |
| Power Supply | 220 VAC ±10%, 50 ±1 Hz, 20 A |
| Dimensions (L×W×H) | 814 × 710 × 1629 mm |
| Weight | ~170 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CS5500 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace (13.56 MHz, 2.7 kVA, Adjustable Power) |
| Carbon Range | 0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample) |
| Sulfur Range | 0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample) |
| Sensitivity | 0.01 ppm |
| Precision | C: ±0.3 ppm or RSD ≤ 0.5% |
| S | ±0.3 ppm or RSD ≤ 0.5% |
| Analysis Time | Minimum 60 s per cycle |
| Sample Mass Recommendation | 0.1–0.5 g |
| Carrier Gas | Oxygen ≥99.5% purity |
| Assist Gas | Nitrogen or inert gas |
| Power Supply | 220 VAC ±10%, 50/60 Hz ±1 Hz, 16 A |
| Dimensions | 620 × 760 × 800 mm (W × D × H) |
| Weight | 107 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Steel Research Institute) |
| Type | Pendulum Impact Testing Machine |
| Model | NCS DFAI |
| Imaging Sensor | 3-Megapixel CCD |
| Measurement Accuracy | ±0.02 mm |
| Compliance | Designed for ASTM E436, ASTM E23, ISO 148-1, ISO 83, GB/T 229, GB/T 8363 |
| Software | Proprietary fracture morphology analysis suite with audit trail and data export (CSV, TIFF, PDF) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FE-1050 Series |
| Instrument Form Factor | Floor-Standing |
| Electron Gun Type | Thermal Field Emission |
| Secondary Electron (SE) Resolution | 1.5 nm @ 1 kV, 0.9 nm @ 15 kV |
| Magnification Range | 10× to 1,000,000× |
| Accelerating Voltage | 0.02–30 kV |
| Backscattered Electron (BSE) Resolution | 2.5 nm @ 1 kV, 1.5 nm @ 15 kV |
| Sample Chamber Port Count | 27 |
| Stage Motion | 5-Axis Motorized (X = 140 mm, Y = 140 mm, Z = 60 mm, Rotation = 360°, Tilt = −10° to +80°) |
| Standard Detectors | In-Column SE Detector, Everhart-Thornley SE Detector, Optional Insertable BSE Detector, Optional STEM Detector, Triple-Channel IR CCD Chamber Monitoring System |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GNT100 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Max Test Load | 100 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% FS (full-scale, no range switching) |
| Force Resolution | 1/500,000 of full scale, constant across entire range |
| Force Indication Error | ±0.5% of reading |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation & Displacement Indication Error | ±0.5% of reading |
| Displacement Resolution | 0.016 µm |
| Crosshead Speed Range | 0.001–500 mm/min (infinitely variable) |
| Force Control Rate Range | 0.005–5% FS/s |
| Strain Rate Range | 0.02–5% FS/s |
| Closed-Loop Control Modes | Constant Force, Constant Strain, Constant Displacement (0.5–100% FS) |
| Speed Accuracy | ±0.2% of set value (0.01–500 mm/min) |
| Effective Tensile Space | 800 mm |
| Effective Test Width | 600 mm |
| Dimensions (H×W×D) | 1921 × 1997 × 660 mm |
| Software Platform | LZCX-800, Windows 7-based, open architecture, graphical UI, multi-method support (tension, compression, bending, shear), unit conversion (N, kN, gf, kgf, lbf, mm, in), real-time stress–strain plotting |
| Protection Functions | Overload, mechanical limit, overcurrent, overvoltage, overtemperature |
| Control Interchange | Seamless, shock-free transition among force, strain, and displacement control modes |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | H5500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Hydrogen Analysis Range | Low-H: 0.1–200 ppm |
| High-H | 200–5000 ppm |
| Hydrogen Precision | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 8.5 kVA, Max Temp: 3500 °C |
| Carrier Gas | Ultra-High-Purity N₂ (≥99.9995%) |
| Dimensions | 63 × 76 × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | NCS (National Center for Steel & Iron Research) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Line Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Analytical Channels | 48 |
| Dispersion | 0.55 nm/mm (1st order), 0.275 nm/mm (2nd order) |
| Optical Resolution | < 0.01 nm |
| Selectable Spectral Lines | 240 |
| Dimensions (W×D×H) | 139 cm × 80 cm × 117 cm |
| Weight | ~400 kg |
| Power Supply | 220 V ±10%, Single-phase, 10 A, 2.5 kVA |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NC-DMT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | NC-MT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | NC-Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | NCS-MMTI600 |
| Price | USD 1 (Reference Only) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Central Iron and Steel Research Institute) |
| Type | Domestic |
| Model | NCS-SJ01 |
| Pricing | Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Steel Research Institute Nano-Characterization Co., Ltd.) |
| Type | Pendulum Impact Tester |
| Compliance Standards | GB/T 229, GB/T 19478–2005, ASTM E23, ISO 14556 |
| Output Data | Load-time, Force-displacement, Energy absorption, Crack initiation & propagation parameters (K₁d, J₁d) |
| Sensor Resolution | High-resolution dynamic load cell & energy transducer |
| Control Interface | Touchscreen-based digital control system |
| Test Modes | Charpy, Izod, Tensile Impact, Bending Impact |
| Report Export | Word, Excel-compatible formats |
| Frame Construction | Monolithic cast steel base and column |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | NX-200S |
| Pricing | Upon Request |
| X-ray Tube | 70 kV end-window micro-focus tube |
| Detector | Imported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV |
| Sample Form | Dry, homogenized powder (no digestion required) |
| Detection Limits (3σ, mg/kg) | Cd 0.16 |
| Battery Life | 8–10 h per charge (removable Li-ion) |
| Operating Temperature | −20 °C to +40 °C |
| Dimensions | 260 W × 350 L × 300 H mm |
| Weight | <4.5 kg |
| Compliance | GBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NX-300 |
| Function Type | Multi-analyte (Cd, Pb, As, Hg, Cr, etc.) |
| Sample Type Compatibility | Solid food matrices (rice, grains, flour, spices, infant formula, dried vegetables) |
| Detection Time | ≤3 min for screening |
| Power Supply | 220 VAC ±10%, 50/60 Hz, 1.5 A |
| Dimensions | 550 W × 330 D × 440 H mm |
| Weight | 30 kg |
| X-ray Source | Air-cooled microfocus X-ray tube |
| Detector | Fast Silicon Drift Detector (FastSDD) |
| Optical Path | Non-destructive, optimized beam collimation and scatter suppression architecture |
| Radiation Safety | Compliant with GBZ 115–2002 “Hygienic Protection Standard for X-ray Diffraction and Fluorescence Analyzers” |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing Central Iron and Steel Research Institute) |
| Model | O5500 |
| Instrument Type | Oxygen Analyzer |
| Analysis Range | Low-Oxygen Mode: 0.1 ppm – 0.5% |
| High-Oxygen Mode | 0.5% – 20% (range adjustable via sample mass) |
| Precision | ±1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temperature 3500 °C |
| Sample Mass | Typically 1.0 g |
| Carrier Gas | Ultra-high-purity argon (≥99.9995%) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing Central Iron and Steel Research Institute) |
| Model | OH5500 |
| Instrument Type | Oxygen-Hydrogen Analyzer |
| Oxygen Range | Low-O: 0.1 ppm – 0.5 wt% |
| High-O | 0.5 wt% – 20 wt% |
| Hydrogen Range | Low-H: 0.1 ppm – 200 ppm |
| High-H | 200 ppm – 5000 ppm |
| Accuracy | O₂: ±1 ppm or ±1.0% RSD |
| H₂ | ±0.2 ppm or ±2.0% RSD |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temp. 3500 °C |
| Detection Principle | Non-Dispersive Infrared (NDIR) for oxygen |
| Carrier Gas | Ultra-high-purity N₂ (≥99.9995%) |
| Sample Mass | Typically 1 g (adjustable to extend range) |
| Dimensions | 63 cm × 76 cm × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Model | ON3500 |
| Oxygen Range (Low) | 0.1 ppm–0.5% |
| Oxygen Range (High) | 0.5%–20% |
| Nitrogen Range (Low) | 0.1 ppm–0.5% |
| Nitrogen Range (High) | 0.5%–50% |
| Oxygen Precision | 1 ppm or RSD ≤ 1.0% |
| Nitrogen Precision | 1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace Power | 8.5 kVA |
| Detectors | Dual-channel NDIR (O₂), TCD (N₂) |
| Carrier Gas | Ultra-high-purity He |
| Auxiliary Gas | Industrial-grade N₂ |
| Furnace Power Supply | 220 VAC ±10%, 50 A |
| Instrument Power Supply | 220 VAC ±10%, 10 A |
| Dimensions (Main Unit) | 58 cm × 70 cm × 68 cm (W×D×H) |
| Dimensions (Furnace Unit) | 48 cm × 70 cm × 68 cm (W×D×H) |
| Weight | 180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing) Technology Co., Ltd. |
| Model | ON5500 |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Sample Mass | 1.0 g (adjustable) |
| Oxygen Range | Low-O: 0.1 ppm–0.5 % |
| High-O | 0.5 %–20 % |
| Nitrogen Range | Low-N: 0.1 ppm–0.5 % |
| High-N | 0.5 %–50 % |
| Accuracy | ±1 ppm or RSD ≤ 1.0 % |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temp. 3500 °C |
| Carrier Gas | Ultra-high-purity He (≥99.9995 %) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Central Iron and Steel Research Institute) |
| Model | ONH3500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.1 ppm–0.5% (low), 0.5%–20% (high) |
| Nitrogen Range | 0.1 ppm–0.5% (low), 0.5%–50% (high) |
| Hydrogen Range | 0.1 ppm–200 ppm (low), 200 ppm–5000 ppm (high) |
| Accuracy | O₂: ±1 ppm or RSD ≤1.0%, N₂: ±1 ppm or RSD ≤1.0%, H₂: ±0.2 ppm or RSD ≤2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Furnace Power | 8.5 kVA |
| Detection Principle | Non-Dispersive Infrared (NDIR) for oxygen |
| Carrier Gas | Ultra-High-Purity Helium or Nitrogen |
| Power Supply | Furnace: 220 VAC ±10%, 50 A |
| Electronics | 220 VAC ±10%, 10 A |
| Dimensions (Main Unit) | 58 × 70 × 68 cm (W×D×H) |
| (Furnace Unit) | 48 × 70 × 68 cm (W×D×H) |
| Weight | 180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ONH5500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Analysis Range | O (Low: 0.1 ppm–0.5 wt% |
| High | 0.5–20 wt%), N (Low: 0.1 ppm–0.5 wt% |
| High | 0.5–50 wt%), H: 0.1–2000 ppm |
| Accuracy | O/N: ±1 ppm or RSD ≤1.0% |
| H | ±0.2 ppm or RSD ≤2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 8.5 kVA, max. temperature ≥3500 °C |
| Carrier Gas | Ultra-high-purity He (≥99.9995%) |
| Dimensions | 63 × 76 × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OPA-1000 |
| Pricing | Upon Request |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Zn at 213.856 nm) | ≤0.003 µg/L |
| Precision (RSD) | ≤0.5% at 1 mg/L (n=10) |
| Short-term Stability (RSD) | ≤0.75% (500×LOD) |
| Long-term Stability (RSD) | ≤1.25% (500×LOD) |
| Wavelength Range | 165–800 nm (2400 g/mm grating) |
| Optical Resolution | ≤0.012 nm (2400 g/mm) |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Plasma 2000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Zn at 213.856 nm ≤ 0.003 mg/L |
| Repeatability | RSD ≤ 0.5% (1 mg/L, n = 10) |
| Short-Term Stability | RSD ≤ 0.5% (500 × LOD) |
| Long-Term Stability | RSD ≤ 1.0% (500 × LOD) |
| Wavelength Range | 165–950 nm |
| Optical Resolution | 0.007 nm (at 200 nm) |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Plasma 3000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppt to ppt (ng/L–µg/L) |
| Precision | RSD ≤ 0.5% (1 mg/L, n = 10) |
| Short-Term Stability | RSD ≤ 0.5% (500×LOD) |
| Long-Term Stability | RSD ≤ 1.0% (4 h, 500×LOD) |
| Wavelength Range | 165–950 nm |
| Optical Resolution | 0.006 nm @ 200 nm |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Resolution (Full Width at Half Maximum, FWHM) | ≤0.8 amu |
| Detection Limits (ng·L⁻¹) | Be ≤ 2 |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 6 |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PlasmaMS 400 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.3–1.0 (Continuously Adjustable) |
| Detection Limits (ng·L⁻¹) | Be ≤ 0.5 |
| Sensitivity (Mcps/mg·L⁻¹) | Li > 80 |
| Short-Term Stability (RSD) | ≤ 2% |
| Long-Term Stability (RSD) | ≤ 3% |