NOSELAB ATS
Filter
Showing all 7 results
| Key | Brand: NOSELAB ATS |
|---|---|
| Origin | Italy |
| Type | Import Instrument |
| Standard Compliance | ASTM D1709 Methods A & B |
| Drop Height Range | 650–1530 mm |
| Clamp Ring Diameter (Outer) | 127 mm |
| Inner Ring Diameter | 125 mm ± 2 mm |
| Actuation | Electromagnetic Release |
| Clamping | Pneumatic Dual-Ring Fixture |
| Safety Enclosure | Acrylic Cylindrical Guard with Dart Recovery System |
| Leveling | Adjustable Horizontal Feet and Vertical Position Control |
| Calibration Tool | Conical Metal Plumb Bob with Suspension Cord and Magnetic Tip |
| Accessories Included | Standard Dart Assembly, Weight Sets, and Optional Test Fixtures |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | 10012006 |
| Operating Temperature Range | −80 °C to +100 °C |
| Sample Capacity | 5 specimens (ASTM D1329) or 10 specimens (ISO R 974) |
| Cooling Options | Dual-coil test bath with compatibility for liquid nitrogen, external cryogenic chiller, or dry-ice-based regulation |
| Bath Volume | 25 L |
| Integrated Dual-Stage Compressor System | Yes (−80 °C capability) |
| Compliance Standards | ASTM D1329, ISO R 974, TR-Test method |
| Safety Features | Automatic pendulum release mechanism, guarded sample positioning, mechanical interlock for operator protection |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | HDT/VICAT |
| Maximum Temperature | 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.2 °C |
| Temperature Stability (Oil Bath Fluctuation) | ±0.2 °C |
| Heating Rates | 50 °C/hr, 120 °C/hr, or Custom |
| Displacement Resolution | 0.001 mm |
| Displacement Accuracy | <0.01 mm |
| Sample Immersion Depth | ≥35 mm |
| Span Between Supports (HDT) | 100 mm (optional 64 mm) |
| Sample Length (HDT) | Up to 102 mm |
| Test Stations | 6 independent positions |
| Weight Load Range | 1–2048 g (binary HDT weights), plus 10 N and 50 N VICAT needles |
| Cooling System | Integrated stainless-steel water-jacketed oil bath with external 18 °C coolant |
| Safety Features | Nitrogen purge interface, physical barrier (mesh screen) between heating/stirring components and sample zone, dual stirrers and heater isolated from test chamber |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, GB/T 1634, GB/T 1633, DIN 53461 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | IMPats 15/25/50 |
| Impact Energy Range | 0–15 J, 0–25 J, 0–50 J |
| Impact Velocity | 2.9 m/s, 3.46 m/s, 3.8 m/s (model-dependent) |
| Pendulum Moment (Impact Constant) | Calibrated per energy range |
| Load Cell Range | Matched to nominal impact energy (0–15 J / 0–25 J / 0–50 J) |
| Maximum Lifting Height | Compliant with ISO 179, ISO 180, ASTM D256, ASTM E23, DIN 53438, UNI EN ISO 13802 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1120218 |
| Display | 5-digit LCD |
| Resolution | 0.001 mm |
| Accuracy | ±0.002 mm |
| Measurement Range | 0–12.5 mm or 0–25 mm (selectable) |
| Zeroing | Manual mechanical zero adjustment |
| Output Interface | RS-232 serial port (printer-compatible) |
| Power Supply | 3 V lithium battery |
| Battery Life | Up to 4000 hours of continuous operation |
| Standard Accessories | Bench-mounted base, precision anvil, calibrated contact probe |
| Optional Accessories | Weighted loading kit (for standardized compressive force), V-groove depth probe |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PNEUMATIC DIE CUTTER |
| Instrument Type | Semi-Automatic Pellet Press |
| Maximum Applied Force | 55 kN |
| Operating Pressure Range | 0–6 bar |
| Max. Sample Thickness | 16 mm |
| Max. Distance Between Die Holder and Worktable | 70 mm |
| Punch Stroke | 18 mm |
| Adjustable Ram Stroke | 30 mm |
| Platen Dimensions | 320 × 200 mm |
| Safety | Dual-Hand Operated Start + Polycarbonate Safety Guard |
| Die Features | Spring-Loaded Ejector Integrated |
| Compliance | ISO 178, ASTM D638, ISO 527, ISO 1856 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | TearATS-200 |
| Maximum Force | 100 N |
| Force Resolution | 0.1 mN |
| Accuracy | ±1% of full scale |
| Measurement Units | mN, N |
| Display | 7-inch color touchscreen interface |
| Data Output | USB 2.0, RS-232 |
| Sample Clamping System | Integrated notch-and-grip fixture |
| Pendulum System | Triple-mass calibrated pendulum with motorized lift mechanism |
| Calibration | Built-in calibration control system |
| Data Storage | Up to 20 test results with parameter tagging |
| Compliance | ASTM D1922, ASTM D1938, ISO 6383-1, ISO 6383-2, TAPPI T414, GB/T 455 |