OI Analytical
Filter
Showing all 12 results
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1030S |
| Compatibility | Requires coupling with OI Analytical Aurora 1030W, 1030C, or 1030D TOC Analyzer |
| Sample Mass Range | 50 µg – 2 g |
| TC/TOC Quantification Range | 0.05 mg – 50 mg |
| Design | Vertical compact footprint |
| Gas Capture Method | Sealed sample bag system for post-combustion CO₂ retention and sequential analysis |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4100 |
| Sample Tray Capacity | 100 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | up to 450 °C |
| Purge Sample Heating Range | ambient to 150 °C |
| Sample Vial Cooling Range | 4–10 °C |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4430 PID Photoinonization Detector |
| Detector Type | Photoionization Detector (PID) |
| Ionization Source | UV Lamp (10.6 eV standard) |
| Design Feature | Window Purge Technology |
| Compatibility | Universal GC Mounting Interface |
| Power Supply | Dedicated High-Voltage Module |
| Application Scope | Selective Detection of Aromatics, Alkenes, and Other VOCs with Ionization Potentials < 10.6 eV |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4450 PID-FID |
| Detector Configuration | Integrated Series-Connected PID and FID |
| Compatible GC Interfaces | Single-detector port (supports dual 4450 installation with OI Dual-Channel Electronics) |
| Column Compatibility | Packed and Capillary Columns |
| Regulatory Alignment | Designed for EPA Method 8021B, ASTM D6728, and USP <467> residual solvent analysis |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4760 |
| Sample Tray Capacity | 100 positions |
| Injection Precision | RSD ≤ 15% |
| Trap Temperature Range | 20–450 °C |
| Purge Heater Temperature | up to 150 °C |
| Sample Vial Cooling Temperature | 4–10 °C |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 5360XSD Halogen-Specific Detector |
| Detector Type | Halogen-selective, GC-compatible |
| Installation | Standard GC detector port (universal mounting interface) |
| Configuration Options | Standalone or in-series with OI 4430 PID |
| Detection Range | Sub-picogram to microgram levels of halogenated compounds |
| Regulatory Compliance | Designed to support EPA Method 8021B, ASTM D7412, and ISO 10302 workflows |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 5390 PID-XSD Tandem Detector |
| Detector Type | Photoionization Detector (PID) + Halogen-Specific Detector (XSD) |
| Configuration | In-series dual-detector module with single column outlet interface |
| Regulatory Compliance | Designed for ASTM D7622, EPA Method 8021B, and USP <621> chromatographic system suitability requirements |
| Software Integration | Compatible with standard GC data systems via analog voltage output (0–1 V) and TTL trigger signals |
| Brand | OI Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DI1000 |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1 Hz |
| Rated Power | 100 W (max), 40 W (standby) |
| Dimensions | 440 mm × 180 mm × 260 mm |
| Weight | 10 kg |
| Detection Limit | 0.001 mg/L |
| Quantification Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Repeatability | ≤3% |
| Zero Drift | ±5% |
| Span Drift | ±5% |
| Linearity | ±5% |
| Analysis Time | 4 min per sample |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% RH |
| Display | 320 × 234 pixel full-color TFT LCD |
| Communication Interfaces | RS-232, built-in thermal printer port |
| Data Storage | 12-month continuous logging with date/time stamping |
| Compliance | USP <643>, Ph. Eur. 2.2.44, ChP TOC method |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | PFPD 5383 |
| Detection Principle | Pulsed Flame Photometry |
| Element Specificity | S, P, N, Cl, Sn, As, Se, Te, and other heteroatoms |
| Dual-Channel Simultaneous Output | Yes |
| Self-Cleaning Combustion Chamber | Yes |
| Modular Electronics & Gas Path Architecture | Yes |
| Compliance | Designed for GC integration per ASTM D5291, EPA Method 1664/1671, USP <621>, ISO 8573-5 |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1030W |
| Detection Principle | High-Temperature Catalytic Oxidation (680 °C) + Solid-State Nondispersive Infrared (SSNDIR) Detection |
| Measurement Range | 2 ppb to 30,000 ppm C |
| Sample Types | Liquid aqueous matrices including suspended solids |
| Oxidation Method | Dual-channel wet chemical oxidation (optional) |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Interface | Integrated Windows CE OS with touchscreen GUI |
| Connectivity | Ethernet-enabled for LAN integration |
| Automation | Optional 88-position rotary autosampler with magnetic stirring or >96-position XYZ autosampler with priority/random sampling |
| Optional Features | Electronic Pressure Control (EPC), Electronic Flow Control (EFC), NPOC/TC/TIC/TOC quantification modes |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1080 |
| Oxidation Method | High-Temperature Catalytic Combustion (680–950 °C) |
| Detector | Solid-State Non-Dispersive Infrared (SSNDIR) |
| Detection Range | TC: 50 ppb–2000 ppm |
| Precision | RSD < 3% |
| Sample Injection Volume | 50 µL–2 mL (adjustable in 10 µL increments) |
| Compliance | ASTM D7573, USP <643>, EPA Methods 415.3 & 9060A, ISO 8245 |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 3700 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Detection Principle | Amperometric Detection after Acid Distillation-Free Digestion |
| Detection Range | 2 ppb – 10 ppm CN⁻ |
| Detection Limit | 0.002 ppm (2 ppb) |
| Sample Throughput | 1 sample per 2 minutes for Total Cyanide |
| Compliance | ASTM D7282, EPA Method 335.4, ISO 11262, GB/T 5750.5–2023 |
| Reagent Preparation Time | <10 minutes |
| System Architecture | Fully Automated, Closed-Loop Reaction Channels |