Olympus
Filter
Showing 1–30 of 69 results
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Custom-Educational Variant |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GE Series |
| Pricing | Available Upon Request |
| Application Field | General Industrial NDT |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | 130D |
| Category | Imported Instrument |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 27MG |
| Weight | 340 g |
| Dimensions (W × H × D) | 84.0 × 152.4 × 39.6 mm |
| IP Rating | IP65 |
| Operating Temperature | –10 °C to 50 °C |
| Battery Life | Up to 150 h (no backlight) / 30 h (with backlight) |
| Thickness Range | 0.080–635 mm |
| Material Sound Velocity Range | 0.508–18.699 mm/µs |
| Resolution Options | 0.1 mm (low) / 0.01 mm (standard) |
| Probe Frequency Range | 2.25–10 MHz |
| Receiver Bandwidth | 1–18 MHz |
| Display | Backlit LCD with color-coded keypad |
| Compliance | EN 15317, MIL-STD-810F Method 511.4, NFPA 70 Class I, Div 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 38DL PLUS |
| IP Rating | IP67 |
| Compliance | EN 15317 |
| Weight | 0.814 kg |
| Operating Temperature | –10 °C to 50 °C |
| Display | Color transflective VGA (56.16 mm × 74.88 mm) |
| Thickness Range | 0.080 mm to 635.00 mm (material- and probe-dependent) |
| Resolution Options | 0.1 mm (low), 0.01 mm (standard), 0.001 mm (high-res option) |
| Sound Velocity Range | 0.508 mm/µs to 13.998 mm/µs |
| Dual-element Probe Frequency Range | 2.0 MHz to 30 MHz (–3 dB) |
| High-Penetration Option | 0.50 MHz to 30 MHz (–3 dB) |
| Data Storage | 475,000 thickness readings or 20,000 waveforms (internal) |
| Interface | USB 1.0, RS-232, VGA video output |
| Battery Life | Up to 14.7 h (Li-ion) |
| Fast charge | 2–3 h |
| Environmental Certification | MIL-STD-810F (shock, vibration, explosive atmosphere per NFPA 70, Class I, Div. 2, Group D) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 39DL PLUS |
| Update Rate | up to 60 Hz |
| Connectivity | Integrated Wireless (Wi-Fi/Bluetooth) |
| Application Type | Precision & Corrosion Thickness Measurement |
| Compliance | Designed for ASTM E797, ISO 16809, and NACE SP0106-compliant inspection workflows |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 45MG |
| Operating temperature | –10 °C to 50 °C |
| Thickness range | 0.080 mm to 635 mm (material-, probe-, and configuration-dependent) |
| Resolution options | 0.1 mm / 0.01 mm / 0.001 mm |
| Sound velocity range | 0.508–18.699 mm/µs |
| Single-element mode | 2.25–30 MHz (standard), 0.5–30 MHz (High Penetration option) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 45MG |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | 72 DLPLUS |
| Type | Portable Ultrasonic Thickness Gauge |
| Measurement Principle | Pulse-Echo Ultrasonic Time-of-Flight (TOF) |
| Minimum Measurable Thickness | ≤0.1 mm (steel equivalent) |
| Display | High-contrast monochrome LCD with backlight |
| Operating Temperature | –10 to 50 °C |
| IP Rating | IP67 |
| Power Supply | Two AA alkaline or lithium batteries (up to 200 hours battery life) |
| Data Storage | Internal memory for up to 500 readings |
| Output Interface | RS-232 serial port (optional USB adapter available) |
| Compliance | Conforms to ASTM E797, ISO 2400, and EN 15317 standards |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ac-ultra |
| Pricing | Available Upon Request |
| Application Sector | Nuclear Energy |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom-Configurable Ultrasonic Array System |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Custom-Engineered AUIS-RB Series |
| Price | Upon Request |
| Application Domain | Metal Forging & Rolling Quality Control, Aerospace & Power Generation Component Inspection |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | Custom-Engineered AUT Line |
| Pricing | Available Upon Request |
| Application Domain | Defense Ordnance & High-Performance Forged Components |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Detection Method | Pulse-Echo Ultrasonic (Conventional & Phased Array) |
| Channel Capacity | Up to 4 Channels |
| Inspection Sensitivity | 0.5 mm × 0.5 mm Flat-Bottom Hole (FBH) Equivalent |
| Material Compatibility | Bearing Steel (e.g., GCr15, SUJ2), Alloy Steels, Hardened & Ground Surfaces |
| Automation Interface | Robotic Arm / Overhead Crane Integration with Machine Vision Guidance |
| Software Platform | Proprietary Real-Time UT Control & Analysis Suite |
| Compliance Framework | Supports ASTM E114, ISO 16847, EN 1330-4, and GLP/GMP-aligned audit trail requirements |
| Connectivity | OPC UA, RESTful API, MES/SCADA Integration Ready |
| Remote Operation | Web-based supervisory control with TLS-secured streaming |
| Brand | Olympus |
|---|---|
| Country of Origin | Japan |
| Model | BF-1TQ290 |
| Insertion Tube Outer Diameter | 6.0 mm |
| Distal Tip Outer Diameter | 5.9 mm |
| Working Length | 600 mm |
| Field of View | 120° |
| Direction of View | Forward |
| Depth of Field | 2–100 mm |
| Instrument Channel ID | 3.0 mm |
| Minimum Focusing Distance | 3.0 mm from distal tip |
| Insertion Tube Rotation | ±120° |
| Compatible Light Source | Olympus CLV-290SL / CLV-290 |
| Compatible Video Processor | Olympus CV-290 |
| NBI (Narrow Band Imaging) | Yes |
| Range ID Function | Yes |
| Waterproof One-Touch Connector | Yes |
| High-Frequency Electrocautery Compatible | Yes |
| Laser Compatibility | Nd:YAG and 810 nm Diode Lasers |
| EBUS-Compatible | Yes |
| Reprocessing Compatibility | Fully compatible with Olympus ETD series cleaners/disinfectors and drying cabinets |
| Sterilization Compatibility | Ethylene Oxide (ETO) and Plasma Sterilization supported |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | BondMaster 600 |
| Compliance | MIL-STD-810G, IP66, CE, FCC, IC, RoHS, RCM, KCC |
| Display | 5.7" VGA (640 × 480) color transflective LCD |
| Weight | 1.70 kg (with Li-ion battery) |
| Dimensions | 236 mm × 167 mm × 70 mm |
| Battery Life | Up to 9 hours |
| Operating Temperature | –10 °C to 50 °C |
| Storage Temperature | 0 °C to 50 °C (with battery) |
| Probe Interface | 11-pin Fischer |
| Gain Range | 0–100 dB (0.1/1 dB steps) |
| Frequency Ranges | RF/Pulse: 1–50 kHz |
| Sweep | 1–100 kHz |
| MIA | 2–50 kHz |
| Resonance | 1–500 kHz |
| Data Storage | 500 files (user-selectable preview) |
| Supported Probes | PowerLink-compatible transducers, standard dual-element probes, MIA-specific probes (B600M), resonance probes (B600M) |
| Software | BondMaster PC Software (included), supports report generation, data review, and GLP-compliant audit trail export |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom OEM System |
| Quotation | Upon Request |
| Application Field | Wind Power Component Quality Assurance |
| Channel Capacity | Up to 4 Channels |
| Inspection Method | Pulse-Echo Ultrasonic Testing with Equivalent Flaw Sizing (FBH Reference) |
| Minimum Detectable Flaw | 0.5 mm × 0.5 mm Flat-Bottom Hole (FBH) |
| Probe Compatibility | Conventional UT & Phased Array UT (PAUT) Probes |
| Automation Interface | Robotic Arm / Overhead Crane Integration with Machine Vision Guidance |
| Software Platform | Proprietary Real-Time UT Data Acquisition & Analysis Suite |
| Key Software Capabilities | Customizable UI, Zone-Based Defect Classification (Functional vs. Non-Functional Areas), Offline CAD-Based Path Planning, Automated Report Generation, Remote Supervisory Control, MES/ERP System Integration (OPC UA, REST API) |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Supplier Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | N/A |
| Pricing | Available Upon Request |
| Application Domain | Industrial NDT for Complex Geometries |
| Brand | Olympus |
|---|---|
| Country of Origin | Japan |
| Model | CV-170 + GIF-H170 + CF-H170L/i |
| Regulatory Clearance | China NMPA Import Registration No. 20152221796 (CV-170), 20143222972 (GIF-H170), 20143222973 (CF-H170L), 20143222945 (CF-H170i) |
| Power Input | 100–240 V AC, 50/60 Hz ±1 Hz |
| Dimensions (W×H×D) | 295 × 145 × 425 mm |
| Weight | 11.0 kg |
| Light Source | Integrated Long-Life LED |
| Video Output | HD-SDI, SD-SDI, DVI-D, RGB/YPbPr (1080i), Composite/Y/C (480i/576i) |
| Image Storage | MAJ-1925 Portable Memory (2 GB, TIFF/JPEG compression) |
| Compatibility | EVIS 100/130/140, OLYMPUS 150, EXERA 160, EXERA II 180, GI/BF/VISERA Series Endoscopes |
| Brand | Olympus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CX3-Y-E |
| Instrument Type | Upright Fluorescence Microscope Module |
| Excitation Source | High-Efficiency LED |
| Light Output Options | 3 W / 5 W / 10 W |
| Control Interface | Motorized Digital Control |
| Fluorescence Filter Sets Included | DAPI, GFP, FITC, Cy3, TRITC, mCherry, Cy5 (custom filter sets available) |
| Integration | Dedicated optical coupling for Olympus CX33 series microscopes |
| Regulatory Status | Not a Medical Device |
| Compliance | Designed for research-use-only (RUO) applications in accordance with ISO 13485–informed quality practices for laboratory instrumentation |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Product Type | Imported NDT Instrument |
| Model | DGS |
| Portability | Portable |
| Compatible Instruments | OmniScan MX2, OmniScan SX |
| Software Version | MXU v4.4 |
| Supported Probe Series | DGS1, Atlas A24 |
| Calibration Standard | DGS (Distance-Gain-Size) Method |
| Regulatory Compliance | ASTM E2700, ISO 16810, EN 13588, ASME BPVC Section V Article 4 |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom-Configured Dual-Arm UT System |
| Pricing | Upon Request |
| Application Domain | Composite Structural Integrity Assessment |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EP650 Integrated Robotic System |
| Pricing | Upon Request |
| Application Scope | Industrial NDT, Aerospace, Power Generation, Petrochemical, and Heavy Manufacturing |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 600 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN12668-1 |
| Weight | 1.68 kg |
| Display | Full VGA (640 × 480), Transflective LCD |
| PRF | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Pulse Width | 25–5000 ns (adjustable via PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 8 standard settings |
| Battery Life | ≥12 h (Li-ion) |
| IP Rating | IP66 (rotary encoder config) / IP67 (keypad config) |
| Operating Temperature | –10 °C to +50 °C |
| Data Storage | 50,000 onboard IDs + 2 GB microSD card |
| Interface | USB OTG, RS-232, VGA output, optional analog output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 650 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasound |
| Compliance | EN 12668-1:2010 |
| IP Rating | IP66 (rotary knob), IP67 (keypad) |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 1.6 kg (with Li-ion battery) |
| Display | Full VGA (640 × 480) transflective color LCD |
| Battery Life | >15 hours |
| PRF | 10–2000 Hz |
| Pulse Energy | 100–400 V |
| Pulse Width | 25 ns–5000 ns (PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 30 standard, including 7 EN-compliant |
| Gain Range | 0–110 dB |
| Dynamic Range | 110 dB (DAC) |
| A-Scan Memory | 100,000 encoded records |
| Storage | Standard 2 GB microSD card |
| Interfaces | USB OTG, VGA, RS-232, analog output (optional), digital I/O, encoder input |
| Probe Connectors | Two BNC or LEMO No.1 |
| Certifications | MIL-STD-810F (shock/vibration/explosion-proof), NFPA 70 Class I, Div. 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LS |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Compliance Standard | NB/T 47013.3–2015 |
| IP Rating | IP65/IP67 |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 890 g (with Li-ion battery) |
| Display | Full VGA (640 × 480), Transflective Color LCD |
| Battery Life | Up to 6 hours |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | Up to 400 V |
| Receiver Bandwidth | DC–26.5 MHz (–3 dB) |
| Digital Filters | 8 preset configurations |
| Gate Count | 2 independent measurement gates |
| DAC Points | Up to 50, 110 dB dynamic range |
| Data Storage | 100,000 waveforms with ID tags |
| Interface | Dual USB (Host + Client), Digital Video Output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LT |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN 12668-1:2010 |
| Environmental Rating | IP65/IP67 |
| Weight | 890 g |
| Display | Full VGA (640 × 480) Transflective Color LCD |
| Battery Life | Up to 6 hours |
| Operating Temperature | –10 °C to 50 °C |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Receiver Bandwidth | DC–26.5 MHz (standard), 0.2–26.5 MHz (EN-compliant) |
| Digital Filters | 8 standard settings |
| Data Storage | 100,000 IDs |
| Connectivity | USB 1.1 host, USB 2.0 client, optional Wi-Fi module |
| Software Compatibility | GageView Pro, Olympus Scientific Cloud |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | FOCUS PX / PC / SDK |
| Phased Array Channels | 16:64PR, 16:128PR, 32:128PR |
| Conventional UT Channels | 4 dedicated |
| Max Simultaneous Units | 4 |
| Data Throughput | up to 60 MB/s (4 units) |
| A-scan Rate | up to 20,000 @ 12-bit resolution (750 points/A-scan) |
| Pulse Voltage Range | PA: 4–115 V |
| UT | 50–190 V |
| Gain | PA: 80 dB (46 dB analog + 34 dB digital) |
| UT | 120 dB digital |
| Pulse Width | PA: 30–500 ns (2.5 ns step) |
| UT | 30–1000 ns (2.5 ns step) |
| Bandwidth (−3 dB) | PA: 0.6–17.8 MHz |
| UT | 0.25–28 MHz |
| Beam Count | up to 1024 |
| PRF | 1 Hz–20 kHz |
| Real-time Averaging | PA: 1–16 |
| UT | 1–64 |
| Gate Count | 4 detection + 1 encoder sync |
| Enclosure Rating | IP65 |
| Operating Temperature | up to 40 °C |
| Dimensions (with housing) | 30.7 × 13.5 × 23.6 cm |
| Weight (with housing) | 4.8 kg |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | FocusPX32128PR |
| Pricing | Upon Request |
| Application Domain | Non-Destructive Testing of Non-Ferrous Metal Components |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |