| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DELTA DE2000 |
| Application | Handheld / Portable |
| Industry Focus | Non-Ferrous Metals & Precious Metals |
| Elemental Detection Range | Mg to U |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | <139 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector Type | Si-Pin Semiconductor Detector |
| Excitation Source | Ta/Au Target X-ray Tube, 4 W Max Power |
| Operating Voltage | Up to 35 kV |
| Cooling System | Peltier Thermoelectric Cooler (Operable down to −35 °C) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Blanview Transflective Color Touchscreen |
| Data Storage | Removable SD Card |
| Compliance | ISO 9001 Certified, NATO AQAPI Qualified |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DE2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.9 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major alloying elements under controlled conditions) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DP2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Na (11) – U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO200 |
| Detector | 25 mm² SDD Silicon Drift Detector |
| Excitation Source | Micro-focus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric Cooling (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution transflective color touchscreen |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% non-condensing |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| OS | Windows CE 6.0 |
| Software | Olympus Delta PC Suite (remote control, report generation, spectral review) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4000 |
| Element Range | Na (11) to U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% RH |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Cooling | Peltier thermoelectric cooling (down to −35 °C) |
| Filters | 8-position automatic filter wheel |
| Battery | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| OS | Windows CE 6.0 |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 + EDR |
| Analytical Modes | Up to 25 user-configurable modes |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4050 |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Excitation Source | High-Power Micro-Focus X-ray Tube (15–50 kV) |
| Cooling System | Peltier Thermoelectric Cooler (operable down to −35 °C) |
| Filter Set | 8-position Automatic Filter Wheel |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Transflective Color Touchscreen |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 4.0 (Microsoft Mobile Device Center compatible) |
| Operating System | Windows CE 6.0 |
| Analysis Modes | Up to 25 User-Configurable Calibration Modes |
| Light Element Compensation | Integrated Barometric Pressure Sensor & Accelerometer for Atmospheric Correction |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DPO6500 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | < 20 eV |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer | Olympus Corporation |
| Type | Imported Instrument |
| Application | RoHS Compliance Screening |
| Form Factor | Handheld / Portable |
| Regulatory Scope | ASTM F2617-08, HR4040, CPSIA, CPSC, EN 71-3, WEEE, RoHS, REACH, ELV Directive |
| Element Detection Range | Mg (12) to U (92), including Ni, Pb, Cd, Hg, Cr, Br, Cl, and halogen sum (Br + Cl) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DP4000 |
| Application | Handheld / Field-Portable |
| Industry-Specific Use | Soil and Environmental Monitoring |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Range | 1 ppm – 100% w/w |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD (at 1000 ppm, 60 s count time) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP4050 |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Na (11) to U (92) |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <130 eV |
| Repeatability | ±0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP6050 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm to 99.9% |
| Energy Resolution | <130 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Product Type | Imported NDT Instrument |
| Model | DGS |
| Portability | Portable |
| Compatible Instruments | OmniScan MX2, OmniScan SX |
| Software Version | MXU v4.4 |
| Supported Probe Series | DGS1, Atlas A24 |
| Calibration Standard | DGS (Distance-Gain-Size) Method |
| Regulatory Compliance | ASTM E2700, ISO 16810, EN 13588, ASME BPVC Section V Article 4 |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DP28 / DP23 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer | Olympus Corporation |
| Origin Category | Imported |
| Model | DP74 |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer | Olympus Corporation |
| Product Type | Imported Digital Microscope |
| Model | DSX1000 |
| Pricing | Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer | OLYMPUS Corporation |
| Product Type | Imported Instrument |
| Model | DSX110 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer | OLYMPUS Corporation |
| Product Type | Imported Instrument |
| Model | DSX2000 |
| Imaging Sensor | 12.37 MP Color CMOS |
| Focus Drive | Motorized Z-axis |
| XY Stage Options | Multiple Standard Sizes (e.g., 100 × 100 mm, 200 × 200 mm) |
| Frame Rate | Up to 60 fps at Full HD |
| 3D Image Comparison | Yes |
| Zoom Ratio | 1×–10× Optical Zoom |
| Total Magnification Range | 26×–7300× (with Objective Lenses & Digital Zoom) |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSX510 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer | OLYMPUS Corporation |
| Type | Imported Instrument |
| Model | DSX510i |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom-Configured Dual-Arm UT System |
| Pricing | Upon Request |
| Application Domain | Composite Structural Integrity Assessment |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EP650 Integrated Robotic System |
| Pricing | Upon Request |
| Application Scope | Industrial NDT, Aerospace, Power Generation, Petrochemical, and Heavy Manufacturing |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 600 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN12668-1 |
| Weight | 1.68 kg |
| Display | Full VGA (640 × 480), Transflective LCD |
| PRF | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Pulse Width | 25–5000 ns (adjustable via PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 8 standard settings |
| Battery Life | ≥12 h (Li-ion) |
| IP Rating | IP66 (rotary encoder config) / IP67 (keypad config) |
| Operating Temperature | –10 °C to +50 °C |
| Data Storage | 50,000 onboard IDs + 2 GB microSD card |
| Interface | USB OTG, RS-232, VGA output, optional analog output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 650 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasound |
| Compliance | EN 12668-1:2010 |
| IP Rating | IP66 (rotary knob), IP67 (keypad) |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 1.6 kg (with Li-ion battery) |
| Display | Full VGA (640 × 480) transflective color LCD |
| Battery Life | >15 hours |
| PRF | 10–2000 Hz |
| Pulse Energy | 100–400 V |
| Pulse Width | 25 ns–5000 ns (PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 30 standard, including 7 EN-compliant |
| Gain Range | 0–110 dB |
| Dynamic Range | 110 dB (DAC) |
| A-Scan Memory | 100,000 encoded records |
| Storage | Standard 2 GB microSD card |
| Interfaces | USB OTG, VGA, RS-232, analog output (optional), digital I/O, encoder input |
| Probe Connectors | Two BNC or LEMO No.1 |
| Certifications | MIL-STD-810F (shock/vibration/explosion-proof), NFPA 70 Class I, Div. 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LS |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Compliance Standard | NB/T 47013.3–2015 |
| IP Rating | IP65/IP67 |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 890 g (with Li-ion battery) |
| Display | Full VGA (640 × 480), Transflective Color LCD |
| Battery Life | Up to 6 hours |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | Up to 400 V |
| Receiver Bandwidth | DC–26.5 MHz (–3 dB) |
| Digital Filters | 8 preset configurations |
| Gate Count | 2 independent measurement gates |
| DAC Points | Up to 50, 110 dB dynamic range |
| Data Storage | 100,000 waveforms with ID tags |
| Interface | Dual USB (Host + Client), Digital Video Output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LT |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN 12668-1:2010 |
| Environmental Rating | IP65/IP67 |
| Weight | 890 g |
| Display | Full VGA (640 × 480) Transflective Color LCD |
| Battery Life | Up to 6 hours |
| Operating Temperature | –10 °C to 50 °C |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Receiver Bandwidth | DC–26.5 MHz (standard), 0.2–26.5 MHz (EN-compliant) |
| Digital Filters | 8 standard settings |
| Data Storage | 100,000 IDs |
| Connectivity | USB 1.1 host, USB 2.0 client, optional Wi-Fi module |
| Software Compatibility | GageView Pro, Olympus Scientific Cloud |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FV4000 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Resolution | High Spatial and Spectral Resolution |
| Lasers | Multiple NIR-capable laser lines (405–785 nm), optional 808/980 nm for upconversion |
| Detectors | Six-channel synchronous silicon-based photodetectors (SilVIR™), 400–900 nm spectral range |
| Fluorescence Detection | SilVIR™ visible-to-infrared silicon detectors with linear response, low noise, and >6-decade dynamic range |
| Scanning Module | Hybrid scanning unit supporting conventional galvo + resonant scanner |
| Scan Modes | Bidirectional resonant scanning, sequential/simultaneous spectral acquisition, Z-stack, time-lapse, tile scan |
| Scan Speed | Up to 438 fps at 1024 × 32 pixels |
| Optical Zoom | Continuous digital and optical zoom with wide dynamic magnification range |
| Objectives | Wide selection of high-NA oil/water/glycerol immersion and dry objectives (e.g., UPLSAPO 60×/1.35, LUCPLFLN 60×/1.20 W) |
| Microscope Frame | Research-grade fully motorized inverted, upright, electrophysiology, or “gate-type” stand |
| Illumination Sources | LED-based fluorescence excitation (white LED + filter wheels), optional halogen or LED brightfield |
| Software Platform | FLUOVIEW v5.x with AI-powered denoising, automated organoid detection, C. elegans motion tracking, and multi-modal experiment scripting |
| Vibration Isolation | Dedicated active/passive anti-vibration tables (multiple footprint options) |
| XY Stage Control | Motorized stage with remote joystick and full software API integration |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | FOCUS PX / PC / SDK |
| Phased Array Channels | 16:64PR, 16:128PR, 32:128PR |
| Conventional UT Channels | 4 dedicated |
| Max Simultaneous Units | 4 |
| Data Throughput | up to 60 MB/s (4 units) |
| A-scan Rate | up to 20,000 @ 12-bit resolution (750 points/A-scan) |
| Pulse Voltage Range | PA: 4–115 V |
| UT | 50–190 V |
| Gain | PA: 80 dB (46 dB analog + 34 dB digital) |
| UT | 120 dB digital |
| Pulse Width | PA: 30–500 ns (2.5 ns step) |
| UT | 30–1000 ns (2.5 ns step) |
| Bandwidth (−3 dB) | PA: 0.6–17.8 MHz |
| UT | 0.25–28 MHz |
| Beam Count | up to 1024 |
| PRF | 1 Hz–20 kHz |
| Real-time Averaging | PA: 1–16 |
| UT | 1–64 |
| Gate Count | 4 detection + 1 encoder sync |
| Enclosure Rating | IP65 |
| Operating Temperature | up to 40 °C |
| Dimensions (with housing) | 30.7 × 13.5 × 23.6 cm |
| Weight (with housing) | 4.8 kg |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | FocusPX32128PR |
| Pricing | Upon Request |
| Application Domain | Non-Destructive Testing of Non-Ferrous Metal Components |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | GoldXpert |
| Form Factor | Benchtop/Floor-standing |
| Industry Application | Non-ferrous Metals |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <50 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD (for Au in certified reference materials) |
| Detector Type | Silicon Drift Detector (SDD) |
| Excitation Source | Micro-focus Rh anode X-ray tube |