PerkinElmer
Filter
Showing 31–60 of 82 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Lambda 650 / Lambda 850 / Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Wavelength Range | 175 nm to 3300 nm (model-dependent: Lambda 650: 190–900 nm |
| Lambda 850 | 175–900 nm |
| Lambda 950 | 175–3300 nm) |
| Linear Dynamic Range | Up to 8 A (Lambda 850/950), 6 A (Lambda 650) |
| Wavelength Accuracy | ±0.08 nm (UV-Vis region) |
| Stray Light | < 0.00008% T at 220 nm (typical) |
| Beam Geometry | Ratio-recording, chopper-synchronized dual-beam |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 750 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Automatic |
| Wavelength Range | 175 nm to 3300 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 850+ |
| Instrument Architecture | Double-Beam |
| Detector Type | R6872 Photomultiplier Tube (PMT) |
| Automation Level | Motorized Wavelength Scanning |
| Wavelength Range | 175–900 nm |
| Wavelength Accuracy | ±0.025 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Imported |
| Model | Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | R6872 Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm (185 nm minimum under nitrogen purge) |
| Spectral Bandwidth | Variable (0.01–8 nm), software-selectable |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Stray Light | <0.00008% T at 220 nm (NaI), <0.0001% T at 340 nm (NaNO₂) |
| Photometric Linearity | Up to 8.0 A (absorbance) |
| Baseline Flatness | ±0.0004 A (190–3300 nm, 1 nm SBW) |
| Automation | Fully motorized optics, auto-lamp switching (D₂ & W/Tungsten), auto-correcting chopper, PC-controlled |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC 300 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) / High-Performance Liquid Chromatograph (HPLC) |
| Pressure Rating Options | 10,000 psi (HPLC mode) or 18,000 psi (UHPLC mode) |
| Detector Options | PDA, Multi-Channel UV/Vis, Single-Channel UV/Vis, Fluorescence, Refractive Index |
| Software Platform | Simplicity™ Chrom CDS |
| Gradient Accuracy | <0.2% RSD |
| System Dispersion Volume | <12 µL (typical, full system configuration) |
| Autosampler Features | Integrated color touchscreen display, programmable sample cooling (4–40 °C), low carryover (<0.005%) |
| Column Oven Temperature Range | 5–90 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | LPC 500 |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MPS 320™ |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | NexION 1000G |
| Instrument Type | Quadrupole ICP-MS |
| Interface Configuration | Triple-cone interface with UltraConic™ design |
| RF Generator | Self-excited solid-state generator with LumiCoil™ technology |
| Ion Optics Architecture | Three-quadrupole tandem mass spectrometry platform (quadrupole ion deflector, quadrupole universal cell, quadrupole mass analyzer) |
| Application Scope | Environmental, geological, food & pharmaceutical, industrial QA/QC, speciation analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NexION 100G |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | NexION 1100/1000G ICP-MS |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 2200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Mass Spectrometry |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | NexION 300Q |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ASTM D5673 and ISO/IEC 17025-aligned protocols |
| Software | Syngistix v3.5 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Detection Limit Performance | Sub-femtogram-level sensitivity for key isotopes (e.g., ⁹Be, ¹¹⁵In, ²⁰⁸Pb) under optimized conditions |
| Vacuum System | Dual-stage turbomolecular pumping with integrated cryo-trapping capability |
| Ion Optics | Triple-cone interface + three quadrupole mass filters (Q1: ion/molecule separation |
| Q2 | universal cell reaction/collision zone |
| Q3 | high-resolution mass filtering) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 5000 |
| Instrument Type | Quadrupole-based ICP-MS |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OilPrep 8 |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Model | OneSource |
| Origin | Shanghai, China |
| Manufacturer Type | OEM |
| Regional Classification | Domestic (China) |
| Service Fee Range | USD 7,000–14,000 per engagement (estimated) |
| Field Experience | >10 years in laboratory relocation and asset lifecycle management |
| Response Time | Within 24 hours |
| Service Scope | Multi-vendor instrument maintenance, calibration, validation, IT integration, and full-lifecycle lab asset governance |
| Service Coverage Cities | Shanghai, Beijing |
| Regulatory Alignment | Supports ISO/IEC 17025, GLP, GMP, FDA 21 CFR Part 11, and USP <1058> compliance frameworks |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Service Model | Laboratory Compliance Program |
| Price Range | USD 2,800 – 7,000 (based on scope and instrument count) |
| Service Type | Instrument Qualification & Computerized System Validation |
| Covered Equipment Types | General Laboratory Instruments (e.g., HPLC, GC, UV-Vis, balances, pipettes, environmental chambers) |
| Years of Experience | 10+ |
| Response Time | Within 24 hours |
| Qualification Scope | Installation Qualification (IQ), Operational Qualification (OQ), Performance Qualification (PQ) |
| Regulatory Alignment | FDA 21 CFR Part 11, GAMP 5, ISO/IEC 17025, ASTM E2500, USP <1058>, ICH Q2(R2), GLP/GMP Annex 11 |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM |
| Regional Classification | Domestic (China) |
| Model | Lab Relocation |
| Quotation | Upon Request |
| Service Fee | USD 7,000–14,000 (approx.) |
| Relocation Experience | >10 years |
| Response Time | Within 24 hours |
| Scope of Service | End-to-end laboratory relocation |
| Service Coverage | Beijing, Shanghai |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Model | PinAAcle 500 |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Deuterium Lamp |
| Flame System | FAST Flame Automated Burner Head Positioning and Gas Control |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Country of Origin | Imported |
| Model | PinAAcle 900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Longitudinal Zeeman |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 400 |
| Instrument Type | Triple Quadrupole (TQ) LC-MS/MS |
| Application Scope | General-Purpose |
| Mass Range | Available upon consultation |
| Sensitivity | Available upon consultation |
| Resolution | Available upon consultation |
| Accurate Mass Capability | Not applicable (unit-mass resolution TQ system) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 500 |
| Instrument Type | Triple Quadrupole (TQ) LC/MS/MS |
| Application Scope | General-purpose quantitative and confirmatory analysis in regulated and research laboratories |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QSight SP50 |
| Automation Level | Fully Automated |
| Channel Configuration | Multi-Channel |
| Extraction Format | Cartridge-Based SPE |
| Solvent Delivery Architecture | High-Pressure, Flow-Controlled Solvent Distribution |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QSight |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Application Domain | General-Purpose Quantitative Analysis |
| Ionization Sources | Dual ESI/APCI Configurable |
| Polarity Switching Speed | Microsecond-Level |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quadrupole Mass Filtering and Collision-Induced Dissociation (CID) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SNFR |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | N9300808 |
| Voltage | 115/230 V |
| Temperature Setpoint Resolution | 0.1 °C |
| Language Options | 10 |
| Safety Messaging | Yes |
| Timer with Auto Shut-off | Yes |
| Segment End Alarm | Yes |
| Integrated Calibration Routine | Yes |
| Compatible With | DigiPROBE Sample Preparation Blocks |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | N9300802 |
| Voltage | 115/230 V |
| Sample Capacity | 50 mL per well |
| Block Configuration | 24-position |
| Coating | PTFE-coated graphite |
| Compatibility | SPB Series sample preparation blocks |
| Manufacturer Type | Authorized distributor (original equipment manufactured in USA) |
