Showing all 5 results
| Brand | Porometer |
|---|---|
| Model | POROLIQ |
| Origin | Germany |
| Technology | Liquid-Liquid Displacement (LLP) |
| Measurement Principle | Capillary Flow Porometry via Immiscible Liquid Pair (e.g., Isopropanol/Water) |
| Minimum Detectable Pore Diameter | 2 nm |
| Data Acquisition Mode | Stepwise Pressure Ramp with Equilibrium Validation Algorithm |
| Compliance Framework | ASTM F316-22, ISO 15901-1, USP <801>, GLP/GMP-ready audit trail support |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX BP |
| Pressure Range | 0–5 bar (0–75 psi) |
| Pore Size Detection Range | 0.13–300 µm |
| Measurement Principle | Bubble Point Method (Capillary Flow Porometry) |
| Compliance | ASTM F316-22, ISO 4003, USP <801> |
| Software | POROLUX Control Suite v3.x (GLP-compliant audit trail, user access levels, 21 CFR Part 11 ready) |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | POROLUX Cito Series |
| Price Range | USD 14,000 – 140,000 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Flow Range | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Measurement Principle | Gas-Liquid Displacement Method (Capillary Flow Porometry) |
| Repeatability | ≤1% |
| Key | Brand: Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX Revo |
| Measurement Principle | Capillary Flow (Gas-Liquid Displacement) |
| Max Flow Rate | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Repeatability | ≤1% |
| Minimum Pore Size | 13 nm |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Brand | Porometer |
|---|---|
| Model | POROLUX™ Revo X |
| Origin | Germany |
| Measurement Principle | Gas-Liquid Capillary Flow (Capillary Flow Porometry, CFP) |
| Pore Size Range | 80 nm – 500 µm |
| Bubble Point Pressure Range | 0–8 bar (0–116 psi) |
| Max. Gas Flow Rate | 200 L/min |
| Dual Auto-Switching Flow Sensors | 0–10 L/min & 0–200 L/min |
| Dual Auto-Switching Pressure Sensors | 0–1 bar & 0–10 bar |
| Sample Holder Diameter | 25 mm |
| Max. Sample Thickness | 3 mm |
| Measurement Modes | Bubble Point (BP x-mL, BP pCF), Mean Flow Pore Size, Minimum Pore Size, Pore Size Distribution, Cumulative Flow Distribution, Gas Permeability |
| Optional Modules | Liquid Permeability, Fluid Source Integration |
| Software | PoreSmart™ with Curve Fitting, Statistical Pore Quantification (Total Pore Count, Total Pore Area [% & µm²], Open Porosity, Calculated Permeability in Darcy) |
| Patented Measurement Method | MP² (Multi-Step Pressure Progression) Technology |
| Compliance Ready | ASTM F316-22, ISO 15709:2022, USP <801>, GLP/GMP Data Integrity Support (Audit Trail, Electronic Signatures, 21 CFR Part 11 Ready) |