PyroScience
Filter
Showing all 3 results
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Plant |
| Measurement Principle | Phase-Fluorescence Quenching (REDFLASH) |
| Oxygen Range (Full Scale) | 0–100% O₂ (gas phase), 0–44 mg/L (aqueous) |
| Oxygen Range (Trace) | 0–21% O₂ (gas), 0–9 mg/L (aqueous) |
| Detection Limit | 0.005% O₂ (gas), 0.002 mg/L (aq) |
| Sampling Frequency | Up to 20 Hz |
| Temperature Compensation | Real-time, integrated Pt100 channel |
| Environmental Operating Range | 0–50 °C, non-condensing |
| Interface | USB 2.0 (bus-powered), UART serial |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Software Suite | Pyro Workbench (acquisition & calibration), Pyro Data Inspector (respiration rate calculation, drift correction) |
| Compliance | ASTM D882-22 (oxygen permeability reference), ISO 20645:2021 (microbial respiration protocols), GLP-compliant audit trail in Pyro Workbench v3.8+ |
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Animal |
| Instrument Type | Research-Grade Animal Metabolism Analyzer (Rodent & Aquatic Models) |
| Measurement Principle | Phase-Fluorescence Lifetime Detection (REDFLASH Technology) |
| Oxygen Range Options | Full-Scale (0–100% O₂ / 0–44 mg/L DO) or Trace-Level (0–21% O₂ / 0–9 mg/L DO) |
| Channel Configurations | 1-, 2-, or 4-Channel Simultaneous Acquisition |
| Temperature Compensation | Real-Time Integrated Pt100 + Internal Thermistor |
| Environmental Sensors | Built-in Barometer (300–1100 mbar, ±3 mbar acc.) & Hygrometer (0–100% RH, ±0.2% RH acc.) |
| Interface | USB 2.0 (Bus-Powered, 5 VDC @ 20 mA) |
| Sampling Rate | Up to 20 Hz per channel |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Operating Temp | 0–50 °C, Non-Condensing |
| Software Suite | Pyro Workbench (Device Control, Calibration, Visualization) + Pyro Data Inspector (Respirometry Analysis, Drift Correction, MO₂ Calculation) |
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Environmental |
| Measurement Principle | Fluorescence Quenching of Oxygen-Sensitive Dyes |
| Optical Sensor Technology | REDFLASH (Rapid Excitation and Detection of Fluorescence) |
| Channel Options | 1-, 2-, or 4-Channel Configurations |
| Power Supply | USB 5V DC (20 mA) |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Operating Temperature | 0–50 °C, non-condensing |
| Integrated Sensors | Barometric pressure (300–1100 mbar, ±3 mbar accuracy), Relative humidity (0–100 %RH, ±0.2 %RH), Pt100 temperature input |
| Sampling Rate | 10–20 Hz per channel |
| Analog Output | 0–2.5 VDC |
| Interface | USB 2.0, UART serial |
| Software Suite | Pyro Workbench (device control & calibration), Pyro Data Inspector (respiration rate calculation, drift correction, TOU analysis) |
| Oxygen Ranges | Full-scale: 0–100 %O₂ (gas phase), 0–44 mg/L (dissolved O₂) |
| Trace | 0–21 %O₂ (gas), 0–9 mg/L (dissolved) |
| LOD | 0.02 %O₂ / 0.01 mg/L (full-scale), 0.005 %O₂ / 0.002 mg/L (trace) |
| Temperature Compensation | Real-time, integrated |
| Sensor Compatibility | Contact-type (probes, needles, bare fiber, solvent-resistant, insertion) and non-contact (optode films, flow cells, respirometry chambers) |
| Compliance | Designed for GLP-aligned workflows |