REMEX
Filter
Showing all 4 results
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-EA |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 325–1000 nm |
| Cuvette Path Length | 10 mm (standard, fixed) |
| Wavelength Accuracy | ≤ ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | < 0.1% T (at NaNO₂) |
| Dark Current Drift | 0.2% T / 3 min |
| Light Current Drift | 0.5% T / 3 min |
| Data Acquisition Rate | 1–100 samples/s |
| Gain Settings | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Pump Speed Control | 0–99 digital steps |
| Number of Pump Channels | 10 (5 per pump) |
| Valve Configuration | 16-position auto/manual selector valve |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IFIS Series |
| Product Type | Flow Injection Sampler |
| Pump Speed Range | 0–99 rpm |
| Maximum Sample Throughput | >600 samples/h |
| Number of Integrated Peristaltic Pumps | Dual |
| Number of Fluid Channels | Up to 10 (5 per pump) |
| Valve Configuration | Dual 16-position auto/manual switching valves (supporting up to 8 independent fluid paths) |
| Programmable Steps | Up to 15 sequences × 10 steps each |
| Control Interface | RS-232/USB |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-A |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| CE High-Voltage Power Supply Output | 0–20 kV / 0–300 µA |
| Photodetector HV Input | −100 to −1000 V |
| Wavelength Response Range | 300–650 nm (peak @ 420 nm) |
| Dynamic Range | >5 decades |
| Amplifier Gain | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Integration Time | 0.001–10 s |
| Sampling Rate | 1–200 Hz |
| Signal Noise | ≤0.5 mV (P-P, 1× gain) |
| Amplifier Drift | <0.05% |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPI-EII |
| Pricing | Available Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Dynamic Range | >5 decades |
| Photometric Accuracy | <0.05% |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Amplifier Drift | <0.05% |
| Peak-to-Peak Noise | ≤0.5 mV (1× gain) |
| Input Impedance (Optical) | ≥10 MΩ |
| Integration Time | 0.01–10 s |
| Sampling Rate | 1–200 Hz |
| PMT High Voltage | −100 V to −1000 V |
| Spectral Range | 230–920 nm (λₚₑₐₖ = 630 nm) |
| Anode Sensitivity | >2000 A/lm |