REMEX (Xi’an Remex Analytical Instrument Co., Ltd.)
Filter
Showing all 3 results
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-F |
| Type | Flow Injection Chemiluminescence (FICL) Analyzer |
| Detection Principle | Photomultiplier Tube (PMT)-based chemiluminescence detection with integrated flow injection manifold and electrochemical compatibility |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Software Interface | Windows-native USB communication protocol (USB 2.0 compliant), real-time data streaming to host PC |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-B |
| Key Components | Integrated Electrochemical Analyzer, Multifunctional Chemiluminescence Detector, CNC Capillary Electrophoresis High-Voltage Power Supply, Microfluidic Chip Multi-Channel HV Power Supply, Flow Injection Sampler, and PMT-Based Luminescence Detection Module |
| Dynamic Range | >5 decades |
| Electrochemical Potential Range | ±10 V |
| Current Range | ±250 mA |
| CE HV Output | 0–20 kV / 0–300 µA |
| Microfluidic HV Output | 0–2000 V per channel (4 or 8 channels) |
| PMT Operating Voltage | −100 to −1000 V |
| Spectral Response | 300–650 nm (peak @ 420 nm) |
| Sampling Rate | 1–200 Hz |
| Integration Time | 0.001–10 s |
| Filter Frequencies | 10/20/50/100 Hz |
| Input Impedance (Electrochemical) | 10 MΩ |
| Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPSE-A |
| Pricing | Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | ≥10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Wavelength Range (Monochromator) | 300–800 nm (standard), optional 200–800 nm |
| Spectral Resolution | 4.32 nm (adjustable via slit pairs: 0.4–7.2 nm, slit widths 0.05–1.0 mm) |
| Wavelength Accuracy | ±0.2% |
| Wavelength Repeatability | ±0.15% |
| Monochromator Scan Speed | 50 nm/s (standard), 100 nm/s (high-speed) |
| Exit Slit Width | 600 µm |
| Scan Modes | Time-based, fixed-point, range-scan, cyclic scan |
| Photodetector Wavelength Range | 230–700 nm |
| Peak Sensitivity Wavelength | 420 nm |
| Detection Method | Single-Photon Counting |
| Integration Times | 1 ms to 3600 s (12 selectable steps) |