| Brand | Autobio |
|---|---|
| Model | AutoLumo A2000Plus |
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Throughput | 200 samples/hour |
| Sample Input Mode | Rotary Disc Loader |
| Sample Types Supported | Serum, Plasma, Whole Blood (with preprocessing), Urine |
| Reagent Loading | Continuous, On-the-Fly |
| Reaction Vessel Handling | Tipless, Inverted Cup Dispensing |
| Magnetic Separation Technology | High-Efficiency Dual-Stage Wash |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Archiving |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB9508 |
| Instrument Type | Electrochemiluminescence Analyzer |
| Automation Level | Fully Automated |
| Detector | Ultra-High-Speed, Low-Noise Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 280–630 nm |
| Detection Sensitivity | <1 amol ATP |
| Sample Introduction | JET Injection Technology |
| Compatible Tube Formats | 12 × 75 mm, 12 × 55 mm, 12 × 47 mm luminometer tubes |
| Injection Volume Range | 10–100 µL or 25–300 µL per channel |
| Injection Accuracy | >98% |
| Software | ICE Operating System with Wizard-Based Interface |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Type | Authorized Distributor |
| Model | FHS/F-01 |
| Power Source | 4× AA Alkaline Batteries |
| Excitation Light Source | High-Intensity Blue LED Array (440–495 nm) |
| Emission Filter Options | Wideband Barrier Filters (470–660 nm) |
| Optical Design | Adjustable Beam Angle Mechanism |
| Compliance | CE Marked for Laboratory Use |
| Battery Life | Up to 3–4 Months (Typical Intermittent Use) |
| Brand | BLS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FHS/T00 |
| Excitation Source | External (e.g., FBL/Basic-B&N-01 benchtop unit) |
| Emission Filter Compatibility | ECFP, EGFP, EYFP, DsRed |
| Filter Options | FS/TEF-1C2 (470–500 nm), FS/TEF-2G2 (500–515 nm), FS/TEF-3GY1 (500–650 nm), FS/TEF-3GY2 (500–550 nm), FS/TEF-4Y1 & FS/TEF-4Y2 (520–650 nm), FS/TEF-4R2-A/B/C (590–660 nm) |
| Compatible Excitation Sources | FS/ULS-02RB, FS/ULS-02B2, FS/ULS-02G2N/W |
| Brand | BLS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FMA-04 |
| Excitation Source | High-Brightness LED(s) |
| Compatible Eyepiece Diameter (D1) | Custom-adaptable, typically 23–30 mm |
| Tube Diameter (D2) | Custom-adaptable, typically 35–45 mm |
| Eyepiece Barrel Length (L1) | Configurable per microscope platform |
| Focal Range (Fmin–Fmax) | 120–220 mm |
| Emission Filter Options | GFP (500–515 nm), GFP/YFP dual-band (500–550 nm), YFP (515–550 nm) |
| Power Supply | 6 V DC |
| Mounting | Three-screw mechanical attachment to focus collar |
| Filter Wheel Positions | “No Filter” (white-light alignment), Green-dot (GFP), Yellow-dot (YFP), Green-Yellow-dot (dual-band) |
| Compliance | CE-marked optical accessory |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-China) |
| Distributor Type | Authorized General Distributor |
| Model | FS/TEF Series |
| Wavelength Ranges | FS/TEF-1C2 (470–500 nm), FS/TEF-2G2 (500–515 nm), FS/TEF-3GY1 (500–650 nm), FS/TEF-3GY2 (500–550 nm), FS/TEF-4Y1 (520–650 nm), FS/TEF-4Y2 (520–650 nm), FS/TEF-4R2 (590–660 nm) |
| Mounting | Standard 25 mm or 32 mm diameter, threaded (M25.5×0.75 or M32×0.75), optical grade anodized aluminum housings |
| Optical Density (OD) | ≥6 at blocking bands |
| Transmission Peak | >90% at center wavelength |
| Steepness | Edge transition <15 nm (typ.) |
| Substrate | Fused silica or BK7, λ/4 surface flatness, AR-coated both sides |
| Brand | BLS |
|---|---|
| Model | GFP-MDS-96/BN |
| Input Voltage | 110/220 V AC |
| LED Configuration | 96 high-brightness LEDs (8 independently steerable excitation channels) |
| Filter Mount | Customizable barrier filter position ahead of objective lens |
| Camera Integration | Adjustable mounting bracket with lens-diameter-specific filter adapter support |
| Intended Use | In situ GFP/YFP visualization in live small-animal housing (e.g., mouse cages) within biosafety cabinets or laminar flow hoods |
| Compliance | Designed for GLP-aligned preclinical imaging workflows |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | Custom Camera Filter |
| Pricing | Available Upon Request |
| Filter Types | FS/CEF-1C2, FS/CEF-2G2, FS/CEF-3GY2, FS/CEF-3GY1, FS/CEF-4Y3, FS/CEF-4Y2, FS/CEF-4Y1, FS/CEF-4R2, FS/CEF-4O2 Emission Filters |
| Brand | Rocgene |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | iFIND |
| Automation Level | Fully Automated |
| Sample Types | Whole Blood, Urine, Cerebrospinal Fluid (CSF), Pleural Effusion, Ascites |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Polaris i1800 |
| Automation Level | Fully Automated |
| Throughput | 180 tests/hour |
| Sample Types | Serum, Plasma |
| Reagent Cartridge Compatibility | KHB Polaris® i2400 |
| Detection Principle | ALP-AMPPD Enzyme-Enhanced Chemiluminescence |
| Sample Volume Precision | CV ≤ 2% at 10 µL, CV ≤ 1% at 200 µL |
| Sample Capacity | 60 positions (6 racks), barcode-readable |
| Reagent Positions | 20, refrigerated (2–8 °C), with magnetic bead reagent agitation |
| Reaction Cup Capacity | 500 disposable cups, auto-replenishable |
| Substrate Delivery | Dual-channel, hot-swap capable |
| Waste Management | 500-cup waste bin, single integrated waste liquid reservoir |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Polaris i2400 |
| Price Range | USD 28,000 – 70,000 (FOB Shanghai) |
| Assay Principle | Indirect Chemiluminescence |
| Automation Level | Fully Automated |
| Throughput | 240 tests/hour |
| Sample Types | Serum, plasma, and other liquid clinical specimens |
| Detection System | ALP-AMPPD chemiluminescent substrate system |
| Sensitivity | ≤10⁻²¹ mol/L |
| Temperature Control Accuracy | ±0.1°C |
| Sample Carryover Prevention | Disposable tip/cup system |
| Regulatory Compliance | CE-IVD, NMPA Registration Class II/III (as per test menu), ISO 13485 certified manufacturing |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-E |
| Pump Speed Range | 0–99 digital steps |
| Dilution Ratio | 1:99 |
| High-Voltage Input | −100 to −1000 V (stability < 0.01%) |
| Spectral Response Range | 300–650 nm (peak sensitivity at 420 nm) |
| Photomultiplier Gain | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Sampling Rate | 1–100 samples/s |
| Analog Signal Input Range | 0–5 V |
| Software | REMEX Chemiluminescence Data Acquisition & Kinetic Analysis Suite (fully localized Chinese UI) |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-B |
| Key Components | Integrated Electrochemical Analyzer, Multifunctional Chemiluminescence Detector, CNC Capillary Electrophoresis High-Voltage Power Supply, Microfluidic Chip Multi-Channel HV Power Supply, Flow Injection Sampler, and PMT-Based Luminescence Detection Module |
| Dynamic Range | >5 decades |
| Electrochemical Potential Range | ±10 V |
| Current Range | ±250 mA |
| CE HV Output | 0–20 kV / 0–300 µA |
| Microfluidic HV Output | 0–2000 V per channel (4 or 8 channels) |
| PMT Operating Voltage | −100 to −1000 V |
| Spectral Response | 300–650 nm (peak @ 420 nm) |
| Sampling Rate | 1–200 Hz |
| Integration Time | 0.001–10 s |
| Filter Frequencies | 10/20/50/100 Hz |
| Input Impedance (Electrochemical) | 10 MΩ |
| Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-1 |
| Dynamic Range | >6 orders of magnitude |
| PMT High-Voltage Supply | −100 V to −1000 V (stability ≤0.05%, current ≥5 mA) |
| Amplifier Gains | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV (p-p, 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 300–650 nm (λₘₐₓ = 420 nm) |
| Radiant Sensitivity | >1000 A/lm |
| Software Features | Real-time zero calibration, auto-gain control, peak/area quantitation, ASCII data export, serial communication interface |