SANXIN-Peirui
Filter
Showing all 8 results
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | 901 |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L |
| Speed Range | 100–2000 rpm (infinitely variable) |
| Temperature Control Range | Ambient to 200 °C (for temperature-controlled variant) |
| Power Supply | DC 6 V (4 × AA batteries or AC adapter) |
| Max. Current Draw | 150 mA |
| Max. Power Consumption | 0.9 W |
| Dimensions | 100 × 146 × 48 mm |
| Weight | 340 g |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 19.99 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation Range | 0–110 °C (ATC) |
| Input Impedance | ≥1 × 10¹² Ω |
| Stability | ±0.01 pH / 3 h |
| Data Storage Capacity | 600 sets |
| Storage Content | Sample ID, pH value, temperature, ATC/MTC mode, date & time |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Protection Rating | IP54 |
| Certifications | ISO 9001:2000, CE, CMC |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MP513 |
| Detection Parameter | Single-Parameter (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–200 mS/cm (5 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to +110 °C |
| Accuracy | ±1.0% FS (Conductivity), ±1.5% FS (Overall Specification) |
| Minimum Resolution | 0.001 µS/cm |
| Temperature Compensation | Automatic (0–50 °C), ATC-enabled electrode |
| Data Storage | 100 sets |
| Interface | RS232 with GLP-compliant software |
| IP Rating | IP54 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | MP525 |
| Instrument Type | Laboratory-grade pH/ORP/Dissolved Oxygen Analyzer |
| Measurement Principles | Potentiometric pH/ORP, Polarographic Dissolved Oxygen |
| Compliance | GLP-compliant design, IP54 rated, ISO 9001:2008 certified, CE & CMC marked |
| Power Supply | DC 9 V / 300 mA |
| Interface | RS232 serial output |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Data Storage | 900 sets with timestamp, temperature, ATC/MTC status, and measurement mode |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | PG100 |
| Instrument Type | Multiparameter Process Controller |
| Measurement Accuracy | ±0.02 pH / ±2 mV |
| pH Range | 0.00–14.00 |
| ORP Range | −1999 to +1999 mV |
| pH Resolution | 0.01 pH |
| ORP Resolution | 1 mV |
| Calibration Solutions | NIST-traceable pH buffer standards (pH 4.00, 6.86, 9.18) |
| Input Signals | 0–5 V DC, 1–5 V DC, 0–10 mA DC, 4–20 mA DC |
| Output Signals | 0–10 V DC, 4–20 mA DC |
| Alarm Outputs | 2 independent relay outputs (configurable as high/low limit with adjustable hysteresis) |
| Control Output | 1 SPST switch output (ON/OFF, selectable direct/reverse action) |
| Power Supply | 90–260 V AC, 50/60 Hz |
| Operating Environment | 0–50 °C, 35–85 % RH (non-condensing) |
| Weight | 0.25 kg |
| Compliance | Designed for industrial process monitoring per IEC 61000-6-2 (EMC immunity) and IEC 61000-6-4 (EMC emissions) |
| Brand | SANXIN-Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Conductivity Calibration Standard |
| Pricing | Available Upon Request |
| Certified Accuracy | ±0.3% at 25 °C |
| Available Conductivity Values | 84 µS/cm, 146.6 µS/cm, 1408 µS/cm, 1413 µS/cm, 12.85 mS/cm, 12.88 mS/cm |
| Volumes | 50 mL, 250 mL, 500 mL per bottle |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | TN450 |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), and 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±6% |
| Compliance | ISO 7027, HJ 1075–2019, DIN 27027 |
| IP Rating | IP67 |
| Data Storage | 200 GLP-compliant records |
| Interface | USB |
| Display | TFT color screen with multilingual UI (English, Chinese, Spanish) |
| Power | 4 × AA batteries |
| Dimensions (instrument) | 90 × 203 × 80 mm |
| Weight (instrument) | 385 g |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YD300 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurement Principle | Spectrophotometric Method (Colorimetric Determination via Calcium/Magnesium Complex Formation) |
| Measured Parameter | Total Calcium and Magnesium Ion Concentration (as Total Hardness) |
| Measurement Range | 0–10 mmol/L (as CaCO₃ equivalent) |
| Repeatability | ≤ ±5% FS |
| IP Rating | IP67 |
| Display | Backlit LCD with Blue Illumination |
| Temperature Compensation | Automatic, 5–50 °C |
| Temperature Range | 0–60.0 °C (±0.5 °C accuracy) |
| Resolution | 0.01 / 0.1 unit (user-selectable per hardness scale) |
| Units Supported | mmol/L, mg/L (CaCO₃), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), °fH (French), °dH (German), °eH (English) |
| Calibration Solutions | B1, B2, B3 standard kits included |
| Power | Battery-operated (low-voltage indicator) |
| Auto Functions | Auto-calibration, auto-zero, auto-hold, auto-shutdown, real-time temperature compensation |