SYSTEA
Filter
Showing all 14 results
| Brand | SYSTEA |
|---|---|
| Model | EasyColi |
| Measurement Principle | Standard Enzyme-Substrate Method (MPN, P/A, TTD) |
| Compliance | HJ 1001-2018, ISO 9308-1:2014 |
| Detection Limit | 1 MPN/100 mL |
| Upper Detection Range | >20,000 MPN/100 mL |
| Sample Throughput | 28 fully automated MPN tests per cycle |
| Sample Independence | Individual incubation chambers per sample |
| Integrated Cleaning Station | Yes |
| Regulatory Support | GLP-compliant data logging, audit trail enabled |
| Software Interface | Touchscreen GUI with real-time assay progress visualization |
| Application Scope | Surface water, drinking water, groundwater, recreational bathing waters, municipal wastewater, industrial effluents |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | EasyTox Max |
| Detection Principle | Bioluminescent Bacterial Inhibition Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Toxicity Output | % Inhibition (qualitative) and EC50 (quantitative, 160× dilution capability) |
| Measurement Frequency | As fast as 2.5 min/cycle |
| Exposure Time | Programmable from 5 min to 24 h |
| Compliance | ISO 11348-3, GB/T 15441 |
| Reagent Storage | Integrated 4–8 °C refrigerated compartment |
| Cleaning | Automated washing station with dedicated rinse cycles |
| Control Interface | Industrial-grade capacitive touchscreen with full programmability |
| Bacterial Maintenance Interval | 8–16 weeks (with on-board reactivation of lyophilized cultures) |
| Brand | SYSTEA |
|---|---|
| Model | EasyTox |
| Measurement Principle | Bioluminescence Inhibition Assay using Marine Luminescent Bacteria (Aliivibrio fischeri, Vibrio qinghaiensis sp.-Q67, or Photobacterium phosphoreum) |
| Compliance | ISO 11348-3, GB/T 15441 |
| Detection Mode | Qualitative (Inhibition Rate %) and Quantitative (EC₅₀) |
| Dilution Range | Up to 160× automated dilution |
| Measurement Interval | 60 s per sample cycle |
| Bacterial Culture Maintenance Interval | 7–14 days |
| Reagent & Control Storage | Integrated 4–8 °C refrigerated compartment |
| Cross-Contamination Control | Dedicated cleaning station with multi-stage rinse protocol |
| User Interface | Programmable touchscreen HMI with full workflow automation |
| Sample Types | Surface water, drinking water, groundwater, municipal wastewater, industrial effluent, seawater |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | EasyTox Pro |
| Measurement Principle | Bioluminescent Bacterial Assay (Aliivibrio fischeri) |
| Quantification Output | EC₅₀ (Half-Maximal Effective Concentration) |
| Analysis Platform | Automated Discrete Analyzer with Robotic Arm |
| Sample Throughput | Dual-channel simultaneous analysis |
| Reaction Vessel Capacity | 80-position rotating cuvette carousel |
| Signal Acquisition Interval | 60 s |
| Assay Duration | 2.5–30 min per sample |
| Bacterial Rehydration | Fully automated lyophilized culture reactivation |
| Operational Autonomy | Up to 90 days unattended (with refrigerated reagent/culture storage) |
| Regulatory Compliance | ISO 11348-3:2007 and GB/T 15441–1995 methods programmable |
| Data Integrity | Audit-trail-enabled software compliant with GLP/GMP documentation requirements |
| Refrigerated Storage Compartment | Dedicated 4 °C zone for lyophilized bacteria, controls, and reagents |
| Cross-Contamination Control | Integrated cleaning station with sequential rinse/flush protocols |
| QC Features | Real-time bioluminescence viability monitoring, dual parallel blank/sample measurement, automatic result validation logic |
| Brand | SYSTEA |
|---|---|
| Model | LabTox |
| Measurement Principle | Bioluminescent Bacterial Toxicity Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Compliance | ISO 11348-3, GB/T 15441 |
| Throughput | Up to 30 samples/hour |
| Sample Capacity | 80-position carousel |
| Dilution Range | Up to 160-fold automated serial dilution (EC50 mode) |
| Dual-Parallel Testing | Blank + sample replicates (inhibition mode) |
| Integrated Cleaning Station | On-board probe and cuvette washing with programmable rinse cycles |
| Software | Windows-based control & analysis suite with audit trail, user management, and data export (CSV, PDF, Excel) |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | SYSTEA |
|---|---|
| Model | ProGC-3500/3600 |
| Application Domain | Natural Gas, Metallurgy, Petrochemical, Coal Chemical, Power Generation, Pharmaceutical |
| Detector Options | TCD, FID, FPD, PDD |
| Explosion Protection Rating | IIC T5 |
| Origin | Zhejiang, China |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | SYSTEA |
|---|---|
| Model | SmarTox |
| Measurement Principle | Bioluminescence Inhibition Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Temperature Control | Refrigerated Reagent Compartment (4–8 °C) & Thermostatic Reaction Chamber (15–25 °C) |
| Detection Interval | 30 s per measurement |
| Data Storage Capacity | >1,000 test records |
| Power Supply | Rechargeable 12.6 V / 11,000 mAh Li-ion battery |
| Compliance | ISO 11348-3, GB/T 15441 |
| Display | Industrial-grade color LCD touchscreen with guided workflow interface |
| Output | Integrated thermal printer for on-site report generation |
| Connectivity | USB data export |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EasyChem |
| Pricing | Available Upon Request |
| Technology | Discrete Batch Analysis with MPN, P/A, and TTD Detection Methods |
| Compliance | ISO 9308-2:2012 (Colilert-based), ASTM D6501, US EPA Method 1604 (adapted) |
| Sample Throughput | Up to 28 MPN tests or 56 P/A–TTD tests per unattended cycle |
| Reagent Compatibility | Colilert®-18/Colilert®-EC, Enterolert®, and other ISO-validated media |
| Sample Independence | Fully isolated incubation wells per sample |
| Integrated Cleaning Station | Automated reagent/sample line flushing and well decontamination |
| Control Interface | 7-inch industrial touchscreen with programmable assay sequences |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | NWP |
| Measurement Parameters | 5-parameter simultaneous in-situ analysis (e.g., NO₃⁻-N, PO₄³⁻, NH₄⁺-N, SiO₂, CODₘₙ or configurable) |
| Detection Limit | 0.001 mg/L (for key analytes) |
| Calibration | Two-point linear calibration (R² ≥ 0.995) |
| Power Supply | 13 V DC (solar-compatible) |
| Filtration Options | Self-cleaning filter cartridges (0.1 µm or 25 µm) |
| Waste Handling | Segregated toxic/non-toxic waste and effluent lines |
| Sample Wash | Deionized water–free cleaning using ambient sample water |
| Remote Operation | Full bidirectional control & real-time status telemetry via external PC |
| Environmental Rating | IP68 submersible housing for buoy, vessel, or emergency field deployment |
| Compliance | Designed to support ISO 5667-3, ASTM D511/D512/D5429/D6508, and EPA Method 300.0/353.2 workflows |
| Brand | SYSTEA |
|---|---|
| Model | WIZ |
| Origin | Zhejiang, China |
| Type | Portable In-situ Multiparameter Nutrient Analyzer |
| Measurement Principle | Micro-circulation Flow Analysis with Integrated Fiber-optic Colorimetry and Fluorescence Detection |
| Supported Parameters | Nitrate, Nitrite, Ammonia, Phosphate, Silicate (5 Nutrient Species Simultaneously) |
| Reagent Consumption | 0.12–0.24 mL per analysis |
| Reaction Volume | 1.5 mL micro-circulation reactor |
| Waste Management | Dual-path separation for toxic vs. non-toxic effluents |
| Filtration Options | Self-cleaning filter modules with 0.1 µm or 25 µm pore size |
| Power Supply | 13 V DC (solar-compatible) |
| Remote Operation | Full bidirectional control & status telemetry via external PC |
| Compliance | Designed for ISO 5667-3, ASTM D3370, and EPA Method 353.2–compatible deployment environments |
| Enclosure Rating | IP68 submersible housing (optional buoy-integrated mounting) |
