TaiKun
Filter
Showing all 5 results
| Brand | TaiKun |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LINCam |
| Instrument Type | Synchronized Scanning Streak Camera |
| Photocathode Material | GaAsP (not "钴ui" — corrected per standard industry nomenclature) |
| Photocathode Active Area | 0.2 mm² |
| Spectral Response Range | 300–900 nm |
| Timing Resolution | 40 ps FWHM |
| Spatial Resolution | 1000 × 1000 pixels |
| Detection Mode | Time-Correlated Single-Photon Counting (TCSPC) |
| Interface | PCIe 3.0 x8 |
| Trigger Input | SMA, LVDS-compatible |
| Software Support | Windows/Linux SDK, MATLAB & Python APIs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing environment |
| Brand | TaiKun |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TK-2020 |
| Typical Configuration | Integrated High-Flow Particulate Sampler |
| Flow Range | 0–20,000 L/min |
| Vacuum Pressure Capability | Up to 2.0 kPa (not L/min — corrected per engineering standard) |
| Continuous Operation Duration at Rated High Flow & Resistance | 24 h |
| Service Life at Maximum Flow and System Backpressure | 168 h |
| Basis Weight | 40 g/m² |
| Thickness | 0.2 mm |
| Filtration Efficiency | 99.995% (NaCl aerosol, 0.3–0.5 µm, face velocity 0.1 m/s, test area 50 cm²) |
| Initial Pressure Drop | 137 Pa (same test conditions) |
| Material | Electrostatically Charged Polypropylene |
| Brand | TaiKun |
|---|---|
| Origin | USA |
| Model | TK-2020-PM2.5 |
| Filter Material | Electrostatically Charged Polypropylene |
| Basis Weight | 40 g/m² |
| Thickness | 0.2 mm |
| Filtration Efficiency | 99.995% (NaCl, 0.3–0.5 µm, face velocity 0.1 m/s, test area 50 cm²) |
| Pressure Drop | 137 Pa (same test conditions) |
| Filter Geometry | Customizable shape and size per client specification |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TK-GEM50P4-83-RB-SMP |
| Instrument Type | Laboratory Gamma Spectrometer |
| Detector Type | P-type Coaxial High-Purity Germanium (HPGe) |
| Measurement Mode | Gamma-ray Spectrometry |
| Sample Form | Solid |
| Energy Range | 30 keV – 10 MeV |
| Relative Efficiency | ≥50% @ 1.33 MeV |
| Energy Resolution (FWHM) | ≤0.85 keV @ 122 keV, ≤1.8 keV @ 1.33 MeV |
| Peak-to-Compton Ratio | ≥53 |
| Peak Shape (FW.02M/FWHM) | ≤3.0 |
| Cooling Method | Electromechanical Cryocooler (Pulse Tube) with 25 L LN₂ Dewar |
| Shielding | Dual-layer low-background lead chamber (15 cm Pb + Cu/Sn lining) |
| Software Compliance | Supports FDA 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TK-Mobius |
| Instrument Category | Gamma-Ray Spectrometer |
| Instrument Type | Laboratory-Based |
| Sample Form | Solid |
| Detector Type | High-Purity Germanium (HPGe) |
| Cooling Method | Liquid Nitrogen Recondensation (Closed-Cycle) |
| Operating Temperature | ≤ 77 K |
| Nominal Dewar Capacity | 28 L |
| Continuous Operation (Uninterrupted Power) | Up to 2 Years |
| Power Consumption | 125 W (Typical), 300 W (Max) |
| Ambient Operating Conditions | 0–40 °C, 20–90% RH (Non-Condensing) |
| Acoustic Noise Level | < 60 dB(A) at 1 m |
| Displayed Parameters | Cryocooler Status, Estimated Remaining Cryogenic Hold Time (h), LN₂ Level, Low-Level Warning Threshold (48 h) |
| Physical Dimensions (Dewar Only) | 66.5 cm H × 44.1 cm Ø |
| Air Filter Maintenance Interval | Monthly |
| Mounting Flexibility | Vertical or Horizontal Cold Finger Orientation |
| Electronics Architecture | Decoupled Cryo-Control and Signal Processing Circuitry (Separated from Dewar) |