TANAKA
Filter
Showing all 13 results
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACR-M3 |
| Standards Compliance | ISO 10370, ASTM D4530, GB/T 17144 |
| Gas Flow Control | Auto-switching between 150 mL/min and 600 mL/min |
| Sample Capacity | 6 × large crucibles (5.0 g each) or 12 × small/medium crucibles (0.15–3.0 g each) |
| Heating Temperature | 500 °C ± 2 °C under inert gas atmosphere |
| Residue Weighing Resolution | 0.1 mg (requires external analytical balance) |
| Condensate Collection | Integrated high-temp resistant, explosion-proof condensate bottle |
| Front-panel Float Flowmeter | Visual flow verification and calibration support |
| Automation Level | Fully automated thermal ramping, dwell, cooling, and end-of-test audio alert (10 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASP-6 |
| Measurement Method | Ring-and-Ball (Dual-Sample) |
| Temperature Range | Ambient to 200 °C |
| Display | 5.7-inch LCD, 0.1 °C resolution |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Interface | RS-232C serial port |
| Power Supply | AC 220 V, 50/60 Hz, 12 A |
| Dimensions (W×D×H) | 230 × 440 × 420 mm |
| Weight | Approx. 14 kg |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AVP-30D2 |
| Test Range | 0–196 kPa (0–2.0 kgf/cm²) |
| Bomb Dimensions | 2/3 standard length, 1/3 standard volume |
| Pressure Sensor | Integrated semiconductor transducer |
| Display | 180 mm × 100 mm LCD |
| Oscillation | Lever-driven, ±15° tilt, 6 s cycle |
| Water Bath | Stainless steel, ~35 mL capacity, PID temperature control with motorized circulation |
| Power Supply | AC 220 V, 50/60 Hz, 15 A |
| Dimensions (W×D×H) | 400 × 600 × 740 mm |
| Weight | ~45 kg (empty bath) |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | LF-1 |
| Standards Compliance | GB/T 12579–1990, ASTM D892–84, JIS K2518–1991 |
| Temperature Control | Dual-bath PID system (24 °C and 93.5 °C) |
| Bath Volume | Ø300 × 460 mm each |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W (24 °C bath), 2 × 1000 W (93.5 °C bath) |
| Cooling Input Power | 600 W |
| Working Medium | Distilled water |
| Stirring Motor Power | 25 W |
| Air Pump Power | 6 W |
| Gas Diffuser | Ø25.4 mm, pore size <80 µm, air permeability 3000–6000 mL/min |
| Graduated Cylinder | 1000 mL |
| Air Flow Rate | 94 ± 5 mL/min |
| Timer Resolution | 1 s |
| Power Supply | AC 220 V, 50 Hz |
| Total Rated Power | 3.3 kW |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | MPC-6 |
| Test Method | ASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016 |
| Sample Volume | 4.5 mL |
| Temperature Interval | 1 °C or 2 °C |
| Repeatability | Pour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval) |
| Cooling Source | Integrated Peltier Module |
| Compliance | ASTM, ISO, GLP-ready architecture |
| Data Output | Auto-generated report with timestamped test logs |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | SDL-2 |
| Standards Compliance | GB/T 7305-1987, ISO 6614:1983, ASTM D1401-1967 |
| Temperature Range | Ambient to 95 °C |
| Number of Test Stations | 5 |
| Cylinder Dimensions | Φ32 mm × 225 mm |
| Bath Dimensions | Φ300 mm × 300 mm (hardened glass) |
| Heating Power | 1.5 kW |
| Bath Stirrer Motor | AC 220 V, 25 W |
| Sample Agitator Motor | DC 24 V, 80 W |
| Timer Channels | 5 independent digital timers |
| Power Supply | AC 220 V, 50 Hz, 7.5 A |
| Control Unit Dimensions | 360 mm (W) × 400 mm (D) × 130 mm (H) |
| Test Chamber Dimensions | Φ360 mm × 590 mm (D × H) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ST1011 |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Number of Test Positions | 6 |
| Heating Power | 2 kW |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 450 × 455 mm |
| Weight | 20 kg |
| Construction | Full stainless-steel housing |
| Compliance | ASTM D130, IP 154, ISO 2160, GB/T 5096 |