Flash Point Ignition Point Instrument
Filter
Showing 1–30 of 92 results
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IP170 |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 300 & ABA 500 |
| Detection Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Temperature Range | 10 °C to 110 °C (air-cooled) |
| Ignition Source | Electronic (encapsulated hot-wire) |
| Repeatability | ±1.4 °C |
| Compliant Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 500 |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −35 °C to +130 °C |
| Ignition Method | Electronic (Encapsulated Hot Wire) |
| Applicable Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CLA 5 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Up to 400 °C (°C/°F selectable) |
| Ignition Source | Pressurized Propane or Butane Gas |
| Compliant Standards | ASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TAG500 |
| Detection Method | Closed-Cup (Tagliabue) |
| Operation Mode | Fully Automatic |
| Temperature Range | −30 °C to +130 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SYD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Active fuel-gas electronic ignition with visible flame |
| Power Supply | AC (220 ± 5%) V, 50 Hz |
| Max. Power Consumption | ≤750 W |
| Temp. Resolution | 0.1 °C |
| Heating Rate | 14–17 °C/min (initial), 5–6 °C/min (final 20 °C before preset flash point) |
| Flame Control | Precision adjustable gas valve |
| Data Transmission | Bluetooth 5.0 |
| Atmospheric Pressure Compensation | Integrated sensor with automatic flash point correction |
| Cloud Data Storage | Encrypted remote sync with audit-ready log history |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SYD-5208 |
| Detection Method | Closed-Cup (Pensky-Martens type) |
| Operation Mode | Fully Automatic |
| Temperature Range | 5°C to 30°C (ambient operating environment) |
| Ignition Method | Electronic spark igniter |
| Applicable Standards | GB/T 5208–2008, ISO 1523:2002, ISO 3679:2004 |
| Flash Point Range | –30°C to +100°C |
| Temperature Resolution | ±0.1°C |
| Cooling System | Integrated compressor-based bath cooling (no external chiller required) |
| Sample Volume | 2 mL (liquid), 4 mL (semi-solid/solid) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤300 W |
| Dimensions (L×W×H) | 490 × 520 × 390 mm |
| Net Weight | 25.5 kg |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0234 |
| Flash Point Range | -30 °C to 50 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Measurement Precision | < 2 °C |
| Sample Volume | 2 mL (liquid), 4 mL (solid/semi-solid) |
| Ignition Method | Electronic spark igniter |
| Cooling System | Peltier thermoelectric cooling with external chilled water circulation |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Ambient | 5–30 °C, 30–80 % RH |
| Compliance | GB/T 5208 (Rapid Equilibrium Closed-Cup Method) |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A-1190 |
| Price Range | USD 4,200 – 7,000 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261-2008, GB/T 21615-2008, ASTM D93 |
| Repeatability | ≤2 °C |
| Ignition Method | Electronic spark ignition and adjustable gas flame |
| Temperature Range | 10–40 °C (ambient operating), 0–350 °C (test range) |
| Resolution | 0.1 °C |
| Data Storage | 120 test records onboard |
| Interface | RS-232 & RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Relative Humidity | <85% RH |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | AFP1 |
| Test Method | Closed Cup (ABEL) |
| Operation Mode | Fully Automatic |
| Applicable Standards | EN 924, IP 170, IP 491, IP 492, ISO 1516, ISO 3679, ISO 13736 |
| Temperature Range | −50 °C to +100 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Repeatability | ±0.1 °C |
| Sensor | Class A PT100 |
| Ignition System | Dual electric spark igniter with ionization flame detection |
| Sample Cup | Brass, ASTM-compliant geometry |
| Safety Features | Thermal cut-off, automatic shutter, integrated flame detection |
| Dimensions (W×D×H) | 310 × 470 × 520 mm |
| Weight | 27 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Display | 8.4″ TFT/LCD touchscreen interface |
| Data Output | Excel-compatible CSV export |
| Compliance | GLP/GMP-ready audit trail, 21 CFR Part 11–compatible software architecture |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | ASTM D1831 |
| Test Method | Open-Cup |
| Operation Mode | Automatic |
| Applicable Standards | ASTM D1831, ASTM D7342 |
| Repeatability | ±0.1°C |
| Ignition Method | Automated temperature-controlled testing |
| Temperature Range | Up to 200°C |
| Rotational Speed | Up to 300 rpm |
| Timer Range | 1 minute to 100 hours |
| Temperature Control Accuracy | ±1°C |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | CFP |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Semi-Automatic (Manual Sample Loading + Automated Detection & Control) |
| Applicable Standards | ASTM D92, FTM 791-1103, IP 36, ISO 2592, JIS K2265-4 |
| Temperature Range | +79 °C to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Heating Sensor | Class A PT100 |
| Ignition System | Dual electric igniters + pilot flame |
| Detection Principle | Ionization-based flame detection |
| Safety Features | Thermal cutoff, real-time fire detection, self-diagnostic routines |
| Dimensions (W×D×H) | 48 × 37 × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Data Output | Excel-compatible CSV files |
| Display | 8-inch integrated TFT/LCD touchscreen PC |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | FPM |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automated |
| Compliant Standards | ASTM D93 (Methods A, B, C), DIN EN 22719, IP 34, ISO 2719 |
| Temperature Range | 0 °C to 420 °C |
| Temperature Resolution | 0.01 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.1 °C |
| Ignition System | Automated electronic spark ignition with temperature-controlled test sequence |
| Sample Chamber | Stainless steel, corrosion- and impact-resistant |
| Temperature Sensors | Dual PT100 (sample & bath) |
| Dimensions (W×D×H) | 37 × 52 × 32 cm |
| Weight | 30 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Origin | Switzerland |
|---|---|
| Type | ASTM D92 Cleveland Open Cup Flash Point Tester |
| Temperature Range | +79 °C to +400 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Probe | PT100 Platinum Sensor (1/10 DIN Class) |
| Sample Cup | ASTM D92 / IP 36–compliant dimensions and fill level markings |
| Heating System | Electronic heater with overtemperature protection |
| Repeatability & Reproducibility | Meets or exceeds ASTM D92 and IP 36 requirements |
| Dimensions (W×D×H) | 48 × 37 × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Ambient Operating Limit | ≤35 °C |
| Safety Certification | CE-marked |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −40 °C to 200 °C (optional high-temp module up to 420 °C |
| LT module with external cooling | −40 °C to 120 °C) |
| Ignition Source | Electric Arc |
| Repeatability | ±4.1 °C |
| Compliance Standards | ASTM D6450, ASTM D7094, SH/T 0768–2005 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash S10 |
| Detection Method | Closed-Cup (ASTM D93 / ISO 2719 / IP 34 / GB/T 261 / SH/T 0768) |
| Temperature Range | −25 °C to 200 °C (optional high-temp module up to 420 °C) |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample (including cup cleaning) |
| Sample Volume | 1 mL or 2 mL |
| Auto-sampler Capacity | 10 positions |
| Data Storage | 100,000 test records |
| Display | 7-inch full-color capacitive touchscreen (Chinese UI) |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-compatible serial protocol |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash X |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 18 °C to 370 °C |
| Ignition Method | Electric Arc Ignition |
| Repeatability | High |
| Compliant Standards | ASTM D7094, SH/T 0768 |
| Sample Volume | 2 mL |
| Cooling/Heating Technology | Peltier-Based Thermoelectric (PBT) |
| Data Storage Capacity | >100,000 test reports |
| Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 85–264 V AC or 12 V DC |
| Pollution Control | CPT Electrode Protection & Self-Cleaning Ignition System |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0292 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261, ASTM D93, ISO 2719 |
| Repeatability | ±1 °C |
| Ignition Methods | Electric Spark & Gas Flame |
| Temperature Range | 10–45 °C (ambient operating) |
| Measurement Range | Room Temperature to 300 °C |
| Resolution | 0.1 °C |
| Heating Rate | 5–6 °C/min (Method A), 1–1.5 °C/min (Method B) |
| Stirring Speed | 90–120 r/min (Method A), 250±10 r/min (Method B) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 500 W |
| Relative Humidity Limit | <85% RH |
| Safety Features | Over-Temperature Protection, Self-Diagnostic System, Pressure-Limited Platinum Wire Heating Control |
| Brand | FlameTech (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0101 |
| Test Method | Cleveland Open-Cup (COC) |
| Temperature Range | –6 °C to 400 °C |
| Compliance Standard | GB/T 3536 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 0–600 W, continuously adjustable |
| Ignition Source | Liquefied petroleum gas (LPG) or natural gas |
| Flame Tip Orifice Diameter | 0.6–0.8 mm |
| Thermometer Range & Accuracy | –6 °C to 400 °C, graduation 2 °C, compliant with GB/T 514 |
| Sweep Mechanism | Motor-driven automatic test flame sweep |
| Enclosure Material | Stainless steel work surface and furnace housing |
| Max. Power Consumption | ≤650 W |
| Operating Ambient | –10 °C to 50 °C, RH ≤85% |
| Safety Features | Integrated flame-extinguishing lid for fire point determination |
| Construction | Benchtop, explosion-resistant quartz-tube heating furnace |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MiniFlash |
| Detection Method | Closed-Cup (ASTM D6450 / D7094, ISO 2719, SH/T 0768-2005) |
| Operation Mode | Fully Automatic |
| Temperature Range | –25 °C to 400 °C |
| Ignition Source | Electric Arc |
| Sample Volume | 1–2 mL |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample |
| Data Storage | Internal memory for multiple test records |
| Connectivity | RS-232, LIMS-ready interface, printer & PC compatible |
| Power Supply | 100/200/230 V AC, 50 Hz, 65 W |
| Optional DC Input | 12 V / 8 A (vehicle battery) |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 8 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLA |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 0 to 200 °C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLAH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 10 to 400°C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | Grabner |
|---|---|
| Country of Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MINIFLASH FP VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | −25 °C to 400 °C |
| Ignition Method | Electric Arc Ignition |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP Vision |
| Detection Method | Closed-Cup (ASTM D6450/D7094) |
| Temperature Range | 0–120 °C (standard), down to –25 °C with external chiller |
| Temp. Stability | ±0.05 °C |
| Sample Volume | 1–2 mL |
| Throughput | Up to 12 samples/hour |
| Interfaces | 4× USB, 2× LAN |
| Power | 100–240 V AC, 50/60 Hz, max. 180 W |
| Dimensions | 253 × 368 × 277 mm |
| Weight | 10.2–11.2 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450 (SH/T 0768) & ASTM D7094 |
| Repeatability | ASTM D6450 ≤ 0.4°C, ASTM D7094 ≤ 0.5°C |
| Reproducibility | ≤ 0.9°C for both methods |
| Ignition Method | Electric Arc |
| Temperature Range | 0–120°C (no external cooling required) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | −25 °C to 400 °C |
| Ignition Source | Electric Arc |
| Repeatability | ≤0.5 °C |
| Compliant Standards | ASTM D6450, ASTM D7094 |