Tannas & King
Filter
Showing all 10 results
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BLB701 / BLB702 / BLB DIN |
| Product Type | Laboratory Instrument |
| Test Parameter | Low-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538) |
| Compliance | ASTM D2983, IP 295, GB/T 6538 |
| Dimensions (W×D×H) | 48 × 53 × 66 cm |
| Weight | ~68 kg |
| Voltage | 220 VAC, 50/60 Hz, Single Phase |
| Fuse Rating | BLB701: 10 A |
| BLB702 | 2 × 10 A |
| BLB-DIN | 12 A max |
| Cooling Capacity | 600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C |
| Heating Capacity | 600 W |
| Temperature Range | BLB701: 30 °C to −40 °C |
| BLB702 | 30 °C to −70 °C |
| BLB-DIN | 30 °C to −55 °C |
| Viewing Window | ~41 × 23 cm |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Safety Features | High-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown |
| Certification | CE |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions | 81 × 76 × 104 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | CP610 |
| Temperature Range | –70 °C to +30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Cooling Capacity | 600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C |
| Cooling Rate | ~30 °C/h (average) |
| Sample Capacity | 4-position rotating bath |
| Bath Volume | 3.8 L |
| Dimensions | 42 × 53 × 66 cm |
| Weight | ~68 kg |
| Power Supply | 220 V, 10 A, 50/60 Hz, single-phase |
| Compliance | ASTM D97, ASTM D2500, ISO 3016, ISO 2084, IP 15, GB/T 6986, GB/T 3536 |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | KV801 / KV802 / KV803 |
| Temperature Range | KV801: +30 °C to –40 °C |
| KV802 | +30 °C to –70 °C |
| KV803 | +40 °C to 150 °C |
| Temperature Stability | ±0.1 °C (digital) / ±0.01 °C (analog) for KV801/KV802 |
| Cooling Capacity | 600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C |
| Heating Capacity | 1500 W (KV803 only) |
| Bath Volume | ~11.5 L |
| Sample Capacity | 4 capillary viscometers (KV801/KV802), 6 capillary viscometers (KV803) |
| Dimensions (W×D×H) | 42 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions (W×D×H) | 81 cm × 76 cm × 104 cm |
| Power Supply | KV801/KV802: 208–220 V, 10 A, 50/60 Hz |
| KV803 | 220 V, 8 A, 50/60 Hz |
| Refrigerants | R410A (KV801), R507/R508B (KV802) |
| Compressor | 1/3 HP |
| Viewing Window | 41 cm × 23 cm |
| Compliance | ASTM D445, GB/T 265 |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | MRV TP-1 |
| Standards Compliance | ASTM D4684 (Method A), SH/T 0562 |
| Temperature Range (BLB702) | 30 °C to −70 °C |
| Cooling Power | 600 W at 0 °C, 100 W at −40 °C, 300 W at −70 °C |
| Heating Power | 600 W |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Dimensions (W×D×H) | 48 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Transport Weight | 122–136 kg |
| Transport Dimensions | 81 cm × 76 cm × 104 cm |
| Electrical Supply | 220 VAC, 50/60 Hz, Single Phase |
| Safety Certifications | CE, High-Temp Cut-off, Low-Level Fluid Detection, Over-Pressure Breaker |
| Viewing Window | 41 cm × 23 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantum |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBR |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS2100E-F / TBS3000 |
| Price | Upon Request |
| Dimensions (Viscometer) | 18 × 30.5 × 35.5 cm |
| Dimensions (Control Unit) | 46 × 46 × 15 cm |
| Dimensions (Auto-sampler, optional) | 46 × 51 × 61 cm |
| Weight (Viscometer) | 15.5 kg |
| Weight (Control Unit) | 9 kg |
| Weight (Auto-sampler) | 25.4 kg |
| Voltage | 220–240 V AC |
| Frequency | 50/60 Hz |
| Sample Volume | 50 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Temperature Range | 40 °C to 200 °C (±0.1 °C stability) |
| Shear Rate Range | 5×10⁴ s⁻¹ to 7×10⁶ s⁻¹ |
| Speed Steps | 12 discrete settings (800–8000 rpm) |
| Overtemperature Protection | Programmable safety limit |
| Compliance | CE-marked |
| Shipping Weight (Manual System) | 68 kg |
| Shipping Weight (Auto System) | 72.5 kg |
| Shipping Dimensions (Manual) | 61 × 81 × 89 cm |
| Shipping Dimensions (Auto) | 61 × 81 × 127 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS 3000 |
| Product Type | Laboratory Instrument |
| Test Parameter | HTHS Viscosity |
| Compliance Standards | ASTM D4683, ASTM D6616, SAE J300, GB/T 6538 |
| Dimensions (W × D × H) | 66 × 66 × 48 cm |
| Weight | 38.5 kg |
| Power Supply | 100–240 VAC, ≤6 A, 50/60 Hz |
| Viscosity Range | 1–30 mPa·s (cP) |
| Sample Volume | 40 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Auto-sampler Capacity | 1–40 samples per sequence |
| Temperature Control Setpoints | 80 °C, 100 °C, 150 °C (±0.1 °C) |
| Shear Rate Range | 5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature) |
| Display | Digital touchscreen interface |
| Safety Features | Automatic torque motor and stator heater shutdown upon power interruption |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TEOST |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TFAB |
| Product Type | Laboratory Instrument |
| Test Parameter | Foam Characteristics |
| Compliance Standards | ASTM D892, IP 146, ISO 6247 |
| Dimensions (W×D×H) | 61 × 61 × 53 cm |
| Weight | 72.5 kg |
| Power Supply | 220 V, Single-phase, 10 A, 50/60 Hz |
| Heating Medium | Forced Air |
| Motor | DC-driven, maintenance-free |
| Aeration Head | Stainless steel cylindrical head with pre-heated air supply |
| Air Flow System | Dual integrated mass flow meters |
| Air Flow Rate | 94–200 mL/min (±5 mL/min) |
| Temperature Range | 20–175 °C (±0.1 °C) |
| Test Programs | Four standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C) |
| Sample Volume | 200 mL |
| Test Capacity | Six 1000-mL graduated cylinders |
| Display | Touchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking |
| Safety | Dual thermal protection (fuse + current-limiting fuse), CE certified |
| Shipping Weight/Dimensions | ~90 kg / 71 × 71 × 122 cm |