TE/Trace Elemental Instruments
Filter
Showing all 7 results
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with VECTRA Liquid Autosampler |
| Analytical Method | Combustion Microcoulometry |
| Measurement Range | 0–10,000 ppm |
| Accuracy | ≤2% CV |
| Detection Limit | 10 ppb |
| Resolution | ≤2% CV |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER AOX |
| Measurement Principle | High-Temperature Combustion–Coulometric Titration |
| Measurement Range | 0.0025–1000 µg Cl/L |
| Accuracy | <3% @ 200 ppb Cl |
| Repeatability | <2.5% RSD |
| LOD | 0.0025 µg Cl |
| Resolution | 0.0025 µg Cl |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | 5–1000 mg (solid) or 0.1–10 mL (liquid) |
| Analysis Time (per sample) | 3–10 min (excluding pre-treatment) |
| Carrier Gases | O₂ (99.6%), Ar (99.998%) |
| Autosampler | Standard 20-position, expandable to 60-position |
| Software | TEIS 2 Online Control & Data Processing Platform |
| Compliance | ISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959 |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER NS |
| Detection Principle | UV Fluorescence for Sulfur / Chemiluminescence for Nitrogen |
| Sample Types | Liquids, Gases, LPG, Solids |
| Measurement Range | S and N from sub-ppb to percent level |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D5453, D7183, D7184 |
| Optional Autosamplers | 105-position 2-mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled UVF and CLD detectors with active feedback loops |
| Automation Level | Fully automated combustion, gas flow control, calibration, and data validation |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Liquids, Gases, Liquefied Petroleum Gas (LPG), Solids |
| Measurement Range | 0.0025–1000 mg absolute chlorine |
| LOD | 0.025 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Software |
| Compliance | ASTM D5808, ASTM D7042, ISO 16939, IP 566, UOP 390, EN ISO 16939, SH/T 0689 |
| Optional Autosamplers | 105-position 2 mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled microcoulometric cell with closed-loop feedback control |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | Xprep C-IC |
| Instrument Type | Laboratory |
| Category | Ion Chromatography Sample Prep System |
| Sample Introduction Modes | Liquid direct injection & Quartz boat solid injection |
| Fraction Collector Capacity | 65 positions |
| Compatibility | Universal IC interface (vendor-neutral) |
| Combustion Capability | Solids, liquids, gases, and LPG |
| Reagent Dispensing | Integrated precision metering system |
| Compliance Context | Designed for ASTM D7359, ISO 14912, USP <643>, and EPA Method 1694-compliant workflows |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with XLS-26 Liquid Autosampler |
| Detection Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 20 ppb – 10,000 ppm |
| Analysis Time | 2–6 minutes per sample |
| LOD | 10 ppb (S and N) |
| Accuracy | ±2% of reading |