Halogen Analyzer
Filter
Showing 1–30 of 48 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 N |
| Measurement Principle | High-Temperature Combustion Coupled with Chemiluminescence (N), UV-Fluorescence (S), and Microcoulometric Titration (Cl/Br) |
| Detection Limits | Sub-ppb for N and S in liquid/gas matrices |
| Analysis Time | 2–5 min per sample |
| Sample Types | Liquids, Gases, LPG, LNG, Solids (with optional solid module) |
| Automation | Unattended 24/7 operation with remote monitoring capability |
| Dimensions | < 0.3 m² footprint |
| Interface | Integrated 10.1" capacitive touchscreen with intuitive GUI |
| Detection Technology | HiPerSens™ optimized signal processing |
| Compliance | Designed to meet ISO 14852, ISO 14855, ASTM D5762, D7183, D7556, USP <381>, and EPA Method 524/525/5310C requirements |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | Chemo |
|---|---|
| Origin | Hubei, China |
| Model | AOX-S |
| Measurement Principle | Combustion-Coulometric Titration |
| Max Combustion Temperature | 1300 °C |
| Sample Introduction Method | Column Adsorption with N₂ Pressurization |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Typical Analysis Time (combustion + titration) | 3–10 min |
| Carrier Gas | O₂ ≥99.6% (optional high-purity O₂ ≥99.999%) |
| Sample Boat | Modified ceramic boat enabling direct sample loading |
| Optional Feature | Automated Sample Introduction Module |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Behr CL10 (AOX/EOX/POX) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.1–3000 mg/L Cl (as Cl⁻ equivalent) |
| Accuracy | <1% RSD |
| Repeatability | <1% RSD |
| Detection Limit | 0.1 µg Cl absolute |
| Resolution | 0.01 µg Cl |
| Carrier Gases | O₂ (99.95%), Ar (99.95% for EOX) |
| IR Furnace Max Temp | 1000 °C |
| Resistive Downstream Furnace Max Temp | 1000 °C |
| Sample Capacity | AOX—up to 200 mL aqueous |
| Analysis Time | 5–10 min per sample (halogen-content dependent) |
| Titration Current Range | 2–450 µA |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX- Organic Halogen Combustion Furnace |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Sample Throughput | Up to 24 samples per batch (standard configuration) |
| Combustion Temperature Range | Ambient to 1100 °C (programmable, ±2 °C stability) |
| Gas Supply | Dual-gas system (N₂ for adsorption, O₂ for combustion) |
| Tube Material | High-purity quartz combustion tube (OD 15 mm, length 600 mm) |
| Integrated Scrubbing System | Five-stage acid/alkali wash bottles + dual absorption traps |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Detection Principle | High-Temperature Combustion Coupled with Ion Chromatography |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Analysis Time (instrumental) | 3–10 min per sample |
| Carrier Gas | O₂ ≥99.6% (recommended ≥99.999%) |
| Accessories Included | Integrated combustion furnace, quartz combustion tube, dual sample boats, quartz push rod, rubber end caps, adsorption column assembly (×2), 1.27 m silicone tubing (OD 15 mm), 5 scrubbing bottles, 2 absorption bottles, 2 absorption tubes, mounting fixtures,纱布,胶布,扎线 |
| Software Option | Real-time instrument control and quantitative data processing module (optional) |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LTX Unique |
| Price Range | USD 55,000 – 69,000 (FOB) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 0.1–200 µg Cl⁻ per sample |
| Accuracy | Better than ±1.5% (for 10–50 µg Cl⁻ or S) |
| Repeatability | <1% RSD |
| Detection Limit | 0.1–200 µg Cl⁻ |
| Resolution | 0.01 µg Cl⁻ |
| AOX/TX/EOX/POX Quantification Range | 0.1–320 mg Cl⁻ (absolute) |
| Analysis Time | 3–6 min per sample |
| Electrolytic Signal Resolution | 5 mV |
| Titration Current Range | 0–2000 µA |
| Electrolyte Volume | 5–35 mL |
| Software | ENGINE XS v5.2 |
| Max. Liquid Sample Volume | 100 mL (AOX/POX) |
| Max. Solid Sample Mass | 5 g |
| Dual-Furnace System | High-Temperature Combustion Furnace (up to 1200 °C |
| Power Supply | 230 V / 50 Hz, max. 1000 W (6 A) |
| Dimensions (L×W×H) | 1070 × 360 × 385 mm |
| Standard Configuration | Main analyzer unit with dual-furnace module, coulometric titration cell, integrated gas purification system, and ENGINE XS software suite |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | LHS20-A |
| Measurement Principle | Halogen Lamp Heating + Gravimetric Loss-on-Drying (LOD) |
| Moisture Range | 0.01%–100% |
| Accuracy | <1% (relative to reference method) |
| Repeatability | ±0.2% RSD (for samples ≥2 g) |
| Minimum Sample Mass | 2 g |
| Readability | 0.001 g |
| Weighing Capacity | 200 g |
| Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Timer Range | 0–120 min |
| Display Parameters | 8 configurable values |
| Interface | RS-232 for printer or PC connectivity |
| Pan Diameter | Φ90 mm |
| Dimensions | 235 × 195 × 195 mm |
| Power Supply | 220 V, 50 Hz or 110 V ±11 V, 60 Hz |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER AOX |
| Measurement Principle | High-Temperature Combustion–Coulometric Titration |
| Measurement Range | 0.0025–1000 µg Cl/L |
| Accuracy | <3% @ 200 ppb Cl |
| Repeatability | <2.5% RSD |
| LOD | 0.0025 µg Cl |
| Resolution | 0.0025 µg Cl |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | 5–1000 mg (solid) or 0.1–10 mL (liquid) |
| Analysis Time (per sample) | 3–10 min (excluding pre-treatment) |
| Carrier Gases | O₂ (99.6%), Ar (99.998%) |
| Autosampler | Standard 20-position, expandable to 60-position |
| Software | TEIS 2 Online Control & Data Processing Platform |
| Compliance | ISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959 |
| Brand | ZOCHI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZC-AOX |
| Price | USD 4,200 (FOB Zhejiang) |
| Measurement Principle | Combustion–Coulometric Titration |
| Measurement Range | 5–1000 µg AOX per sample |
| Accuracy | ±1% of reading |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L (sample-dependent) |
| Resolution | 0.01 µg |
| Brand | ZOCHI |
|---|---|
| Origin | Zhejiang, China |
| Model | ZC-AOX-3 |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8–1000 µg/L |
| Resolution | 0.01 µg |
| Compliance | Designed for ASTM D5907, ISO 9562, and EPA Method 1650 |
| Brand | Zhochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Measurement Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Quantification Range | 5–1000 mg sample mass |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8–1000 µg/L (as AOX) |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Uniformity | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| [Brand | Zhochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration or Ion Chromatography |
| Temperature Range | 100–1150 °C |
| Max. Temp. Stability | ±1 °C |
| 炉 Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1.5 kW |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L |
| LOD | 0.8 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% |
| Resolution | 0.01 µg |
| Avg. Analysis Time (combustion only) | 3–10 min |
| Gas Requirements | O₂ ≥99.6% (99.999% recommended) |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008] |
| [Brand | Zhuchi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Microcoulometric Titration |
| Measurement Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Combustion Temperature | 1150 °C |
| Furnace Temp Control Stability | ±1 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Compatible Detection Systems | Microcoulometer or Ion Chromatograph |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (W×D×H) | 345 × 360 × 660 mm |
| Net Weight | 26 kg] |
| [Brand | Zhuchi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration or Ion Chromatography |
| Detection Range | 0.8 µg/L – 1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008] |
| Key | Principle: High-Temperature Combustion + Microcoulometric Titration |
|---|---|
| Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% |
| LOD | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Temp | 1150 °C |
| Temp Stability | ±1 °C |
| Furnace Zone | 200 mm |
| Power | 1.5 kW, 220 V/50 Hz |
| Dimensions | 345×360×660 mm |
| Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-1000 |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg/L (as Cl⁻) |
| Accuracy | ±1% |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L |
| Resolution | 0.01 µg |
| Compliance | Designed to meet ISO 9562 and EPA Method 1650 requirements for AOX determination |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AOX-3 |
| Price | USD 4,200 (FOB Zhejiang) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.8–1000 µg/L as Cl⁻ |
| Accuracy | ±<5% (vs. certified reference materials) |
| Repeatability (RSD) | <5% at ≥10 µg/L |
| Limit of Detection (LOD) | 0.8 µg/L as Cl⁻ |
| Resolution | 0.1 µg/L (digital display) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Measurement Principle | Combustion–Coulometric Titration |
| Measurement Range | 0.8–1000 µg/L |
| Accuracy | <5% |
| Repeatability | <5% |
| Limit of Detection (LOD) | 0.8 µg/L |
| Resolution | 0.8 µg/L |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion–Microcoulometric Titration |
| Measurement Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Combustion Temperature | Up to 1150 °C |
| Furnace Temperature Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Measurement Range | 5–1000 mg sample mass |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8–1000 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | Up to 50 °C/min (adjustable) |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Coulometric Titration or Ion Chromatography |
| Detection Range | 0.8 µg/L – 1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| LOD | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Measurement Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Measurement Range | 5–1000 mg sample mass |
| Detection Range | 0.8 µg/L – 1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Operating Temperature | 1150 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | Up to 50 °C/min (adjustable) |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 |
| Detection Principle | High-Temperature Combustion Coupled with Microcoulometric Titration |
| Detection Range | 0.8–1000 µg/L |
| Accuracy | ±1% |
| Repeatability | ≤1% RSD |
| LOD | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Combustion Temperature | 1150 °C |
| Furnace Temp Control Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber | φ40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Dimensions (W×D×H) | 345 × 360 × 660 mm |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-3 |
| Price | USD 3,950 (FOB) |
| Detection Principle | High-Temperature Combustion Coupled with Microcoulometric Titration or Ion Chromatography |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Accuracy | ±1% |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8 µg/L |
| Resolution | 0.01 µg |
| Max Combustion Temperature | 1150 °C |
| Temperature Control Stability | ±1 °C |
| Heating Rate | Adjustable up to 50 °C/min |
| Furnace Chamber Dimensions | Ø40 × 300 mm |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Net Weight | 26 kg |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-3 Standard |
| Measurement Principle | High-Temperature Combustion Coupled with Coulometric Titration |
| Detection Range | 0.8 μg/L to 1000 μg/L |
| Accuracy | <1% |
| Repeatability | <10% |
| Limit of Detection (LOD) | 0.1 μg |
| Resolution | 0.01 μg |
| Max Combustion Temperature | 1150 °C |
| Sample Introduction | Pressurized Nitrogen-Driven Column Adsorption (5–1000 mg) |
| Analysis Time (Combustion & Detection) | 3–10 min (excluding pre-concentration) |
| Required Gases | O₂ ≥99.6% (99.999% recommended), N₂ for adsorption |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-3-ZC |
| Price | USD 4,200 (approx.) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg AOX per sample |
| Accuracy | ±1% (relative to certified reference material) |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L (sample-dependent, based on 100 mL preconcentration volume) |
| Resolution | 0.01 µg (coulometric current integration) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-S |
| Pricing | Upon Request |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Furnace Temperature Range | 500–1000 °C |
| Temperature Accuracy | ±1% ±5 °C |
| Measurement Accuracy | <5% |
| Repeatability | <5% |
| Limit of Detection (LOD) | 0.1 µg/L (as Cl⁻ equivalent) |
| Resolution | Not specified |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-S Zhuochi |
| Measurement Principle | Combustion-Microcoulometric Titration |
| Temperature Range | 500–1000 °C (±1 % ±5 °C) |
| Accuracy | <5 % |
| Repeatability | <5 % |
| Limit of Detection | 0.1 µg/L |
| Compliance | HJ 1214–2021 (China EPA Standard for Water Quality — Determination of Adsorbable Organic Halogens by Microcoulometry) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | AOX-S |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Temperature Range | 500–1000 °C (±1% ±5 °C) |
| Accuracy | <5% |
| Repeatability | <5% |
| Limit of Detection (LOD) | 0.1 µg/L |
| Compliance | Designed per HJ 1214–2021 (China National Standard for AOX in Water) |