Thwing-Albert
Filter
Showing all 8 results
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ALFA 240-10 |
| Maximum Cutting Area | 305 × 305 mm (12" × 12") |
| Stroke Length | 48" (1219.2 mm) |
| Dimensions (W × D × H) | 736 × 394 × 584 mm |
| Weight | 135 kg |
| Cutting Force | 8 tons (71.2 kN) |
| Drive Type | Electromagnetic-hydraulic |
| Safety Activation | Dual-hand, palm-button interlock system |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | HOM |
| Maximum Test Force | 1000 g |
| Frequency Range | 50/60 Hz |
| Host Weight | 22.2 kg |
| Measurement Range | 0–100 g / 0–1000 g |
| Resolution | 0.1 g |
| Adjustable Slit Widths | 5, 10, 20 mm and 1/4 in |
| Display | 2 × 40-character LCD |
| Power Supply | 220 V ±10%, 50 Hz |
| Sample Size | 203.3 mm × 203.2 mm |
| Dimensions (L×W×H) | 304.8 × 254.0 × 317.5 mm |
| [Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | PCA-1270 |
| Load Cell Options | 500 g, 2000 g (standard), 5000 g, 10000 g |
| Force Accuracy | ±0.25% F.S. |
| Bending Mode Speed | 11.46°/sec |
| Score (Unfolding) Mode Speed | 5–500 mm/min |
| Angular Range | 0–90° (adjustable) |
| Angular Resolution | <0.2° |
| Displacement Accuracy | ±0.1% F.S. |
| Sample Width (Bending) | up to 152.4 mm |
| Sample Length (Score) | 25.4–457.2 mm |
| Pneumatic Pressure Requirement | 5.2 bar (75 psi) |
| Power Supply | 220 V ±10%, 50 Hz, 250 VA |
| Standby Power | 11 W |
| Test Power | 90 W |
| Fuse | 0.5 A @ 230 VAC |
| Analog Output | 1 V |
| Dimensions (W×D×H) | 610 × 483 × 1143 mm |
| Net Weight | 41 kg |
| Display Units | g, oz, lb, N, kg (force) |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProGage Touch Thickness Tester |
| Measuring Range | 40–500 mil (1–12.7 mm) |
| Accuracy | ±0.00004–±0.0005 in (±0.001–±0.013 mm) |
| Display Resolution | 0.00001–0.0001 in (0.01–0.1 µm) |
| Parallelism | ±0.00004–±0.0005 in (±0.001–±0.013 mm) |
| Pressure Foot Diameter | 0.19–2.221 in (4.83–56.41 mm) |
| Anvil Diameter | 2.5 in (63.5 mm) standard, 4.25 in (107.9 mm) optional |
| Dwell Time | 0–20 s adjustable |
| Measurement Speed | 0.013–12.7 mm/sec |
| Sampling Rate | 128 Hz |
| Power | 120–230 VAC, 50–60 Hz, 36 VA |
| Dimensions | 255 × 318.5 × 403.9 mm |
| Net Weight | 24.7 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProTear |
| Measurement Principle | Elmendorf Pendulum Tear Method |
| Compliance Standards | ASTM D1922, D1424, D295, D751 |
| Display | 4-line × 16-character LCD, multi-angle viewing |
| Accuracy | ±0.2% of pendulum capacity |
| Sample ID Input | 13-character alphanumeric |
| Data Storage | Up to 99 test results |
| Statistical Functions | Mean, Std. Deviation, Min/Max, Variance |
| Units | gf, lbf, mN, % of pendulum capacity |
| Fixture | Pneumatically actuated clamping |
| Pendulum Release | Pneumatic |
| Power Supply | 220–230 V ±10%, 50 Hz |
| Power Consumption | ≤10 W |
| Dimensions (L×W×D) | 578 × 483 × 398 mm |
| Operating Temp. | 10–50 °C |
| Storage Temp. | −25–70 °C |
| Sample Compatibility | Paper, board, film, foil, nonwovens, coated fabrics, packaging laminates |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-10 |
| Sealing Temperature Range | 20–400 °C (±0.15 °C accuracy) |
| Temperature Resolution | ±0.1 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms–99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | 362 kg (1000 lbf) total capacity, ±0.09 kg (±0.2 lbf) accuracy & repeatability |
| Peel Load Cell | 11.34 kg (25 lbf), 0.1% FS accuracy, ASTM E-4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Range | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794.2 mm |
| Weight | 79.3 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-2 |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 200 ms–99 s (with 10 ms resolution at low load |
| Time Accuracy | ±25 ms |
| Time Repeatability | ±50 ms |
| Jaw Length | Up to 304.8 mm (12 in) |
| Jaw Width | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Options | Flat, Grooved, Custom or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended: 90 psi) |
| Dimensions (W×D×H) | 584.2 × 400 × 620 mm |
| Weight | 72.5 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Type | Electromechanical Universal Testing Machine |
| Model | Vantage |
| Force Capacity | 0–1 kN |
| Optional Load Cells | 5 N to 1 kN |
| Force Accuracy | ±0.25% of reading |
| Crosshead Travel | 609.6 mm |
| Vertical Test Space | 89 mm |
| Speed Range | 1.27–1016 mm/min |
| Power Supply | 220 V, 60 Hz |
| Safety Features | Emergency stop button, upper/lower limit switches, overload protection |
| Interface | RS-232 serial port |
| Control Software | MAP (Materials Analysis Program) for Windows |
| Actuation | Electronically controlled pneumatic grips |
| Calibration | Automated electronic zeroing and simplified calibration routine |
| Control Panel | Magnetic, repositionable |