Titan Instruments
Filter
Showing 31–60 of 96 results
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn: <0.01 µg/L |
| Hg, Cd | <0.001 µg/L |
| Ge | <0.05 µg/L |
| Zn | <1.0 µg/L |
| Au | <3.0 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1,000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Control System | Valve Island |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1,000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Control System | Valve Island |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | <0.8% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Yes |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | AFS-9320 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual sequential injection pump |
| Waste Liquid Disposal | Peristaltic pump aspiration |
| Hydride Generation Mode | Vapor generation / hydride generation |
| Gas Flow Control | Mass flow controller |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| Relative Standard Deviation (RSD) | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1000 °C (adjustable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Yes |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | AMSP-100 |
| Sample Introduction Modes | Headspace, Liquid Injection, SPME (Solid-Phase Microextraction) |
| Auto-Needle Exchange | Yes |
| Vial Bottom Detection | Yes (enables ≤10 µL residual sampling) |
| Collision Detection | Yes |
| Agitation Method | Oscillatory (stir-bar-free) mixing |
| GC/GC-MS Compatibility | Universal (vendor-neutral interface) |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AMSP-100 |
| Instrument Type | Multifunctional Autosampler |
| Sample Introduction Modes | Headspace, Liquid Injection, Solid-Phase Microextraction (SPME) |
| Automation Features | Automatic Needle Exchange, Bottle Bottom Detection, Collision Detection, Oscillatory Mixing |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software Interface | RS-232/USB/Ethernet-compatible control protocol |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Laboratory Benchtop Analyzer |
| Repeatability | RSD ≤ 3.0% |
| Limit of Detection | ≤ 0.05 mg/L |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | APLE-1000 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 18 MPa (2700 psi) |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL, 150 mL |
| Extraction Cycle Time | 8–20 min per sample |
| Dimensions (W×D×H) | 86 × 76 × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Heating System | Single-zone furnace with ±1 °C temperature control |
| Pressure Control | Balanced pressure regulation, active control initiated at ±0.3 MPa deviation |
| Filtration & Cleanup | Integrated inline filtration and post-extraction cleanup module |
| Safety Features | Real-time temperature/pressure monitoring with audible/visual alarm |
| Compliance | Designed in accordance with GB/T 19649–2006 for pesticide residue analysis in agricultural products |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Cycle Time per Sample | 8–20 min |
| Dimensions | 78.3 × 67.5 × 77.3 cm |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APLE-3500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Extraction Cycle Time | 15–20 min per sample |
| Dimensions (W×D×H) | 86 cm × 76 cm × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 rinse positions) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-3500 |
| Extraction Pressure | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Pump Flow Rate | 100 mL/min |
| Extraction Cell Volumes | 1, 5, 11, 22, 34, 66, and 100 mL |
| Cycle Time per Sample | <20 min |
| Solvent Consumption (typical) | ≥1.5 mL per 1 g sample |
| Compliance | EPA Method 3545, HJ 782–2016, HJ 783–2016 |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extract Cell Volumes | 1, 5, 11, 22, 34, 46, 66, and 100 mL (8 options) |
| Extraction Cycle Time | 10–20 min per 2 samples |
| Dimensions | 655 × 720 × 725 mm (W × D × H) |
| Sample Capacity | 26 positions (24 sample + 2 rinse) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-5000 |
| Extraction Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 46 mL |
| Extraction Time | 10–20 min per 2 samples |
| Dimensions (W×D×H) | 655 × 720 × 725 mm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-5000 |
| Extraction Mode | Parallel & Sequential Dual-Channel |
| Sample Capacity | 24 positions (unattended) |
| Solvent Compatibility | Common organic solvents (e.g., acetone, dichloromethane, hexane, methanol, ethyl acetate) |
| Operating Pressure | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Extraction Cell Options | 1, 5, 10, 22, 34, 66, and 100 mL |
| Collection Precision | ±0.1 mL |
| Control Interface | Windows-based software with Wi-Fi remote access |
| Data Integrity | Audit trail, user authentication, method versioning, and electronic signature support compliant with GLP/GMP requirements |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | APNE-12 |
| Pricing | Available Upon Request |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Vial | ≤200 mL |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APNE-12 |
| Instrument Type | Automated Quantitative Nitrogen Concentrator |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Vial | ≤200 mL |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APNE-12 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | DMA-500 |
| Pricing | Upon Request |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection (No Acid Digestion Required) |
| Automation | 100-Position 4-Axis Robotic Autosampler |
| Thermal Treatment | Dual-Zone PID-Controlled Ashing & Catalytic Combustion Furnace |
| Trapping System | Constant-Power Heated Mercury Trap with Rapid Thermal Ramp |
| Detection Architecture | Tandem Dual-Absorption Cells + Dual-Beam Light Source Correction |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | DMA-500 |
| Sample Introduction | Solid, Liquid, Gas (Direct Analysis, No Digestion Required) |
| Detection Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Release and Dual-Absorption-Cell Optical Path |
| Automation | 4-Axis Robotic Autosampler (100-position) |
| Temperature Control | PID-Controlled Ashing & Catalytic Combustion Furnaces |
| Mercury Trap | Constant-Power Heated Trap (Rapid Thermal Response, Zero Memory Effect) |
| Optical System | Dual-Beam Light Source with Real-Time Drift Compensation |
| Compliance | Designed for ISO 17025-accredited laboratories |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DMA-600 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection |
| Dual Sample Preparation Pathways | Catalytic Thermal Decomposition + Gold Amalgamation OR Stannous Chloride Reduction + Gold Amalgamation |
| Furnace Control | PID Temperature Regulation (Ashing & Catalytic Combustion Zones) |
| Mercury Trap | Constant-Power Heated Trap |
| Absorption Cell | Dual-Temperature-Controlled Flow-Through Cells (Heated to Maintain Hg⁰ in Vapor Phase) |
| Optical System | Dual-Beam Reference Compensation |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FSI-12 |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | FSI-12 |
| Application Standard | GBZ/T 192.4–2007 |
| Automation Level | Unattended Operation |
| Sample Throughput | 12-position high-throughput carousel |
| Reagent Handling | Automated pyrophosphoric acid dispensing |
| Digestion Control | Dual-sensor independent channel temperature regulation (±0.5 °C) |
| Stirring | Adjustable speed per channel |
| Filtration | Optimized funnel geometry with real-time liquid-level monitoring |
| Compliance | Designed for occupational hygiene laboratories requiring traceable, auditable sample preparation per Chinese national standards |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-IMS 1000 |
| Form Factor | 19-inch rack-mountable (4U height) |
| Ionization Source | Non-radioactive, low-power UV photoionization lamp (10.6 eV) |
| Polarity Mode | Dual-polarity (positive and negative ion detection) |
| Detection Limit | Sub-ppt (v/v) for selected volatile organic compounds |
| Sample Introduction | Negative-pressure direct draw sampling |
| Flow Path Materials | Fully inert (SilcoNert®-treated stainless steel, PFA, and fused silica) |
| Control Interface | Integrated industrial PC with native Chinese-language software suite |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GC-IMS 2000 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-IMS 2000 |
| Configuration | Integrated GC (GC-200) + Dual-Polarity IMS (dIMS-200) + Automated Multi-Mode Sampling Platform |
| Ionization Source | Non-radioactive UV photoionization (10.6 eV) |
| Detection Polarity | Positive and negative ions simultaneously |
| Sensitivity | Sub-ppt (v/v) for volatile organic compounds |
| Software | Fully localized Chinese-language workstation with GLP-compliant audit trail, method/sequence automation, fingerprint spectral generation, and multivariate statistical analysis modules |
| Compliance | Designed to support ISO 17025 workflows, ASTM D7923 (VOCs in air), USP <1225> method validation principles, and FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | GC-IMS 3000 |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-IMS 3000 |
| Configuration | GC-IMS300 Main Unit + BP30 Rechargeable Battery Pack + HS30 Handheld Sampling Probe |
| Power Supply | Dual-mode (AC adapter & internal Li-ion battery) |
| Operating Environment | 5–40 °C, <85% RH (non-condensing) |
| Dimensions (Main Unit) | 320 × 240 × 180 mm |
| Weight | ≤8.5 kg (fully configured) |
| Sample Introduction | Negative-pressure direct draw via inertized capillary path |
| Ionization Source | Non-radioactive UV photoionization lamp (10.6 eV) |
| Polarity Mode | Bipolar (simultaneous positive/negative ion detection) |
| Detection Limit | Sub-ppt (v/v) for selected VOCs and S-compounds |
| Data Acquisition Rate | Up to 50 spectra/sec |
| Software Interface | Standalone Windows-based GUI with embedded chemometric tools |