Titan Instruments
Filter
Showing 91–99 of 99 results
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Flow Rate Range | 0.01–10.000 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 10,500 PSI (72 MPa) at 0–2 mL/min |
| Flow Accuracy | ≤0.06% RSD |
| Autosampler Capacity | ≥108 positions (1.5 mL vials) |
| Injection Volume Range | 20–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5+ |
| Product Type | Flow Injection Analyzer |
| Portability | Integrated carry-on case with shock rating IK08, IP67-rated (submersible to 1 m for 30 min) |
| Detection Principle | Flow Injection Analysis (FIA) coupled with dual-beam spectrophotometry |
| Sample Introduction | Automated peristaltic pumping with intelligent flow path control |
| Pre-treatment Modules | On-board distillation, digestion, and liquid–liquid extraction |
| Detection Limits | Sub-ppb (ng/L) for target analytes including cyanide, phenols, ammonium, nitrate/nitrite, phosphate, Cr(VI), sulfide, and anionic surfactants |
| Software | Embedded method library, real-time system status monitoring, self-diagnostic interface, GLP-compliant audit trail |
| Connectivity | LAN and Wi-Fi enabled for multi-channel synchronization and remote operation |
| Compliance | Designed to support ASTM D3869, ISO 6776, ISO 15681-2, USP <621>, and EPA Method 354.1 workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Hyphenated LC-AFS System for Elemental Speciation |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Speciated Elements | As(III), As(V), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| RSD | <5% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As(III) ≤0.04 µg/L, DMA ≤0.08 µg/L, MMA ≤0.08 µg/L, As(V) ≤0.2 µg/L, SeCys ≤0.3 µg/L, SeMeCys ≤1 µg/L, Se(IV) ≤0.3 µg/L, SeMet ≤2 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | SA-50 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Atomic Fluorescence Spectrometry System |
| Application Scope | Elemental Speciation Analysis |
| Configuration | Modular, Integrated LC Pump(s), Dual-Column Oven, Column Switching Valve, UV Photochemical Reactor with Auto-Activation, Four-Channel Peristaltic Pump, LED Status Indicators, Optional Autosampler (96-/120-position) |
| Software | Unified Control Platform for Total Element and Speciation Quantification, Method Management, Hybrid Sequence Scheduling, Real-Time Instrument Monitoring, System Self-Diagnosis, Customizable Reporting Templates |
| Compliance Framework | Designed to support GLP/GMP-aligned workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Titan Instruments |
| Model | SAP-50 |
| Instrument Type | LC–AFS Hyphenated System for Elemental Speciation |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride/Vapor Generation Mode | On-line Hydride Generation (HG) and Cold Vapor Generation (CVG) |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Species | As(V), As(III), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| RSD | <4% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As(III) ≤0.04 µg/L, DMA ≤0.08 µg/L, MMA ≤0.08 µg/L, As(V) ≤0.2 µg/L, SeCys ≤0.3 µg/L, SeMeCys ≤1 µg/L, Se(IV) ≤0.3 µg/L, SeMet ≤2 µg/L |
| PMT Wavelength Range | Not specified |
| Atomizer Temperature Control Range | Not specified |
| Brand | Titan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Holographic Digital Grating + TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm (SupNIR-2700), up to 2500 nm (SupNIR-2720/2750) |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.05 nm |
| Absorbance Noise | <50 µA |
| Stray Light | <0.1% |
| Analysis Time | <60 s |
| Max. Simultaneous Parameters | 30 |
| Sample Mass | <120 g |
| Light Source Lifetime | >5000 h |
| Communication Interface | USB 2.0 |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 5–85 % RH |
| Power Supply | 198–242 V AC, 50 Hz, 0.5 A |
| Dimensions (L×W×H) | 400 × 420 × 360 mm |
| Weight | 18 kg |
| Chemometrics Software | RIMP (PLS, ANN, SIMCA, Hierarchical Clustering) |
| Model Transfer Capability | Cross-instrument compatible |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Analytical Instrument |
| Model | WX-AFS-820 |
| Service Fee Range | USD 700–1,400 (excl. parts) |
| Response Time | Within 12 hours |
| Service Scope | Maintenance, calibration, fault diagnosis, component replacement, and performance validation for domestic and imported atomic fluorescence spectrometers |
| Technician Experience | 10+ years in AFS system servicing |
| Compliance Support | ASTM D5673, ISO 11929, GB/T 223.74–2008, USP <233> |