Titan Instruments
Filter
Showing 61–90 of 96 results
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GC-MS 8700 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-MS 8700 |
| Mass Analyzer Type | Single Quadrupole |
| Mass Range | Up to 1250 amu |
| Ion Source | High-Temperature Inert Ceramic |
| Vacuum System | Dual-Chamber Design with 250 L/s Turbo Molecular Pump |
| Ionization Modes | Electron Ionization (EI) |
| Scan Modes | Full Scan (SCAN) and Selected Ion Monitoring (SIM) Simultaneously |
| Filament | Dual Long-Life Inert Filament |
| Pre-Quadrupole | Removable |
| Detector | Electron Multiplier with Active Protection Logic |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ASTM D5847, ISO 17025–compliant data handling, and supports 21 CFR Part 11–ready audit trail configuration (via optional software module) |
| Brand | Titan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ICP-5000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | µg/L (ppb-level) |
| Repeatability | RSD ≤ 0.5% |
| 4-Hour Stability | RSD < 2.0% |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤ 0.007 nm (at 200 nm) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ICP-5500 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limits | Al 167.0 nm, P 178.2 nm, B 182.6 nm, Se 196.0 nm, Pb 220.3 nm, Na, K — all < 10 µg/L |
| Precision (RSD) | ≤0.5% at 1 mg/L (n=10) |
| Long-Term Stability (RSD) | ≤2.0% at 1 mg/L over 4 h |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤0.007 nm (FWHM at Mo 202.030 nm) |
| RF Generator Power | 0.5–1.6 kW, continuously adjustable |
| Plasma Observation Mode | Dual-view (axial + radial) |
| Detector | High-resolution solid-state CCD/CMOS array (>1 M pixels), thermoelectrically cooled to ≤−45 °C |
| Background Correction | Real-time, pixel-by-pixel |
| Linear Dynamic Range | ≥4–5 orders of magnitude |
| Warm-up Time | ≤30 min (optical chamber stabilized at 35 °C ± 0.1 °C) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA 7Plus |
| Product Type | Flow Injection Analyzer |
| Category | Chemical Analysis Instrumentation — General Analytical Instruments — Flow Injection Analyzer |
| Manufacturer Status | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Type | Integrated Flow Injection Analyzer (FIA) System |
| Configuration | Fully Automated, Channel-Independent Modular Design |
| Standard Package | Auto-sampler, Main Unit, Control PC, Thermal Printer |
| Optional Modules | MAC3 Multi-Analyte Configuration Module (17 parameters) |
| Compliance Context | Designed for ASTM D129, ISO 6775, ISO 1192, EPA 300.0, EPA 354.1, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 10–50 mL per vial / 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA L9 |
| Wavelength Range | 600–700 nm |
| Sample Capacity | 50–212 positions |
| Reagent Ports | 7 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA5+ |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA7 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 Plus |
| Product Type | Flow Injection Analyzer |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | iFIAE |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume Capacity | 10–50 mL per vial |
| Sample Tray Capacity | 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (As, Sb, Se, Bi, Te, Hg, Sn, Pb) | <0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin A12 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin A13 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Detection Limit | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin A18 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Kylin |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Method | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Programmable and Element-Optimized |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (As, Sb, Se, Bi, Te, Hg, Sn, Pb) | <0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin S12 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin S13 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin S18 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| RSD | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Optical System | Fully Orthogonal Dual-beam 3D Optical Path |
| Number of Channels | 2–4 Configurable |
| Reference Drift Correction | Enabled on All Channels |
| Hollow Cathode Lamps | Plug-and-Play Smart Lamps with Embedded Memory Chip |
| Lamp Current Monitoring & Usage Timer | Supported |
| Atomizer | Shielded Quartz Tube with Auto-height Adjustment & Temperature Control (100–400 °C) |
| Gas Flow Control | EFC (Electronic Flow Control) with PID Regulation, Real-time Pressure/Flow Monitoring & Safety Interlock |
| Vapor Generation | Chemical Vapor Generation with Multi-stage Gas-Liquid Separation |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn: < 0.01 µg/L |
| Hg, Cd | < 0.001 µg/L |
| Ge | < 0.05 µg/L |
| Zn | < 1.0 µg/L |
| Stability (Drift) | ≤1.5% |
| Noise | ≤1.5% |
| Inter-channel Interference | ≤±1.0% |
| Repeatability | ≤0.6% RSD |
| Linearity | >3 Orders of Magnitude |
| Power Supply | 220 V, 50 Hz, Max 400 W |
| Dimensions (H×W×D) | 52 cm × 76 cm × 68 cm |
| Net Weight | 40 kg |
| Communication Interfaces | LAN, USB, RS-232 |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L9 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Flow Rate Range | 0.01–10.000 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 10,500 PSI (72 MPa) at 0–2 mL/min |
| Flow Accuracy | ≤0.06% RSD |
| Autosampler Capacity | ≥108 positions (1.5 mL vials) |
| Injection Volume Range | 20–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |