Waters
Filter
Showing 91–120 of 130 results
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep SFC 150 Mgm |
| Type | Preparative |
| Maximum CO₂ Flow Rate | 150 mL/min |
| Modifier Flow Range | Up to 150 mL/min |
| Fraction Collection Positions | 6 × 2 L |
| Operating System | Windows 10 |
| Control Software | Waters ChromScope 2.0 SFC |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Preparative Supercritical Fluid Chromatography (SFC) System |
| Model Variants | 80, 200, 350 |
| Application Level | Laboratory-Scale Purification |
| Regulatory Context | Designed for GLP-compliant workflows and compatible with FDA 21 CFR Part 11–enabled software environments |
| Compliance Framework | Supports ASTM D7894–21 (Standard Guide for SFC Method Development), ISO 17025–2017 (Testing Laboratory Competence), and USP <621> Chromatography guidelines |
| Software Platform | SuperChrom v3.x (with audit trail, electronic signatures, and method versioning) |
| Detection | UV-Vis absorbance detection (dual-wavelength capability) |
| Fraction Collection | Automated, timed or peak-triggered, with solvent compatibility up to 100% CO₂-expanded liquids and polar modifiers (e.g., methanol, ethanol, isopropanol) |
| Back Pressure Control | Active Automatic Back Pressure Regulator (ABPR) with ±0.2 bar pressure stability |
| Solvent Delivery | Dual-pump architecture — primary CO₂ pump (supercritical phase delivery) and auxiliary modifier pump (liquid-phase co-solvent gradient) |
| System Architecture | Modular, rack-mounted configuration with integrated safety interlocks, CO₂ phase monitoring, and real-time density compensation |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Quattro Micro |
| Instrument Type | Triple Quadrupole Gas Chromatography Tandem Mass Spectrometer (GC-MS/MS) |
| Configuration | Benchtop |
| Ionization Sources | ESI, APCI, ESCi |
| Mass Range | 5–3,000 m/z |
| Scan Speed | Up to 5,000 amu/s |
| Interface Technology | Z-Spray™ ion interface |
| Typical Service Life | 6–8 years |
| Warranty | 6 months post-installation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | RADIAN ASAP |
| Ionization Principle | Atmospheric Pressure Solid Analysis Probe (ASAP) |
| Mass Analyzer | Single Quadrupole |
| Detection Mode | Full Scan / Selected Ion Monitoring (SIM) |
| Sample Introduction | Direct Solid & Liquid Analysis |
| Software Platform | LiveID, IonLynx, OpenLynx |
| Compliance Support | FDA 21 CFR Part 11 (audit trail, electronic signature), GLP/GMP-ready workflows |
| Dimensions | Compact benchtop footprint (< 60 cm width) |
| Typical Analysis Time | < 30 seconds per sample |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SELECT SERIES Cyclic IMS |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SELECT SERIES MRT |
| Mass Analyzer Type | Multi-Reflecting Time-of-Flight (MRT-TOF) |
| Instrument Class | High-Resolution Accurate-Mass (HRAM) LC-MS/MS System |
| Application Scope | Universal (Life Sciences, Clinical Research, Forensics, Materials Surface Analysis) |
| Pressure Range | Not Applicable (Vacuum-operated analyzer) |
| Ion Sources Supported | DESI XS, SELECT SERIES MALDI, Electrospray (ESI), APCI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SQD2 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Compatibility | UPLC, HPLC, UPC², SFC, Prep-LC, Prep-SFC, ASAP Direct Analysis |
| Ionization Modes | ESI, APCI, UniSpray, ZSpray |
| Mass Range | 0–3000 m/z |
| Software Platform | MassLynx, OpenLynx Open Access, AutoPurification Integration |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | SYNAPT G1 HDMS |
| Instrument Type | Hybrid Quadrupole–Time-of-Flight (Q-TOF) Mass Spectrometer with Ion Mobility Separation (IMS) |
| Mass Analyzer Configuration | Dual-Mode TOF (V-mode: >10,000 resolution |
| W-mode | >17,500 resolution) |
| Mass Accuracy | <5 ppm (with lock mass correction, ≤1000 Da) |
| m/z Range | TOF mode — 20–100,000 (V-mode), 20–16,500 (W-mode) |
| Scan Rate | Up to 10 Hz (standard MS/MS), 5 Hz (PDR/E mode) |
| Included Modules | ACQUITY UPLC System (Binary Solvent Manager, Sample Manager, Column Manager, PDA Detector), ESI & NanoSpray Ion Sources, MassLynx 4.2 Software Suite, IMS Hardware, Vacuum System (Agilent G1960-80040 + Varian MS40+ POWERVAR), UPS, Dedicated PC Workstation |
| Refurbishment Standard | Factory-reconditioned per Waters OEM specifications |
| Operational Age | 5–7 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Fully compatible with GLP/GMP data integrity requirements when configured with audit-trail-enabled MassLynx and validated workflows |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYNAPT XS |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | Universal |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | TQD |
| Configuration | Integrated UPLC/MS/MS System |
| Ionization Options | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Range | 50–1200 m/z |
| Typical MRM Sensitivity | <10 fg on-column for reserpine (S/N ≥ 20:1) |
| Scan Speed | Up to 8,000 Da/sec in MRM mode |
| Collision Cell | T-Wave™ RF-only quadrupole collision cell |
| Data Acquisition Rate | ≥20 MRM transitions/sec |
| Software Platform | MassLynx v4.1 with TargetLynx, QuanLynx, QCMonitor, RADAR, TrendPlot, InliStart, and Quanpedia modules |
| Compliance | Fully compatible with 21 CFR Part 11 audit trail requirements and GLP/GMP workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | UNIFI |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo CDMS |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-S QTof |
| Instrument Type | Quadrupole Time-of-Flight (Q-TOF) Mass Spectrometer |
| Configuration | Integrated with ACQUITY H-Class UPLC System |
| Age | 4–5 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Software | MassLynx v4.2 or later with UNIFI-ready architecture |
| Detection Mode | Full-scan MS, MSE, MS/MS (via ion mobility-enabled fragmentation), High-resolution accurate-mass (HRAM) acquisition |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-XS QTof |
| Mass Range | 20–16,000 m/z |
| Resolution | >40,000 FWHM (at m/z 556) |
| TOF Mass Range | >100,000 m/z |
| Mass Accuracy | <1 ppm (external calibration) |
| Acquisition Rate | ≥30 spectra/sec |
| Detector | 6 GHz digitizer with 5-decade linear dynamic range |
| Instrument Age | 4 years |
| Warranty | 12 months |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Model | Xevo G3 QTof |
| Application Scope | Universal LC-MS/MS Platform |
| Mass Range | Not specified in source data |
| Resolution | Not specified in source data |
| Mass Accuracy | Not specified in source data |
| Sensitivity | Not specified in source data |
| Pressure Range | Not specified in source data |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo MRT |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Resolution | 100,000 FWHM at 100 Hz |
| Mass Accuracy | <500 ppb |
| m/z Range | Broad, consistent across full scan range |
| Analyzer Architecture | Multi-Reflecting Time-of-Flight (MRT) with 4-meter effective flight path and 8 reflections |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | Universal LC-MS/MS Quantitation |
| Mass Range | Not specified by manufacturer in public datasheets |
| Sensitivity | Up to 15× higher for challenging negative-ion-mode analytes vs. prior-generation TQ systems |
| Resolution | Unit mass resolution standard for SRM/MRM transitions |
| Mass Accuracy | Not specified (typical for QqQ: ±0.1–0.2 Da under routine conditions) |
| Operating Pressure Range | Vacuum system maintained at <1×10⁻⁶ mbar in analyzer region |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute XR |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | Universal LC-MS/MS Analysis |
| Mass Range | Not Specified by Manufacturer |
| Sensitivity | Not Specified by Manufacturer |
| Resolution | Not Specified by Manufacturer |
| Mass Accuracy | Not Specified by Manufacturer |
| Operating Pressure Range | Not Specified by Manufacturer |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-GC |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Gas Chromatography (GC) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) |
| Software Platform | TargetLynx™, Quanpedia™, IntelliStart™ |
| Compliance Framework | Designed for GLP/GMP environments |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) in triple quadrupole configuration |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo TQ-S cronos |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | Xevo TQ-S cronos |
| Configuration | LC-MS/MS System |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry in Multiple Reaction Monitoring (MRM) mode |
| MRM Transition Rate | Up to 555 transitions per second |
| Linear Dynamic Range | >5 orders of magnitude |
| Typical Precision | <4% RSD for challenging analytes with 5 ms dwell time |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP audit trails, ISO/IEC 17025-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo TQ-S micro |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQ-S micro |
| Ion Sources Compatibility | ESI, APCI, ESCi, UniSpray, APGC, ionKey/MS, ASAP, Nanoflow ESI |
| LC Compatibility | ACQUITY UPLC H-Class PLUS/Bio PLUS, I-Class PLUS, UPC2, M-Class |
| Key Technology | Z-Spray Ion Source, StepWave Off-Axis Ion Focusing |
| Regulatory Alignment | Compliant with SANTE/11813/2017, FDA 21 CFR Part 11 (via MassLynx software), GLP/GMP data integrity requirements |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-S Micro |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Dynamic Range | >5 orders of magnitude |
| Detection Mode | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI), switchable |
| Typical Dwell Time | <10 ms per transition |
| Mass Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Scan Speed | Up to 15,000 Da/sec |
| Quantitative Reproducibility | <5% RSD for low-level analytes across multi-day runs |
| Warranty | 6 months limited hardware warranty |
| Operational Age | <12 months |
| Configuration | Integrated with Acquity UPLC I-Class system, Sample Manager, Binary Solvent Manager, Column Heater, MassLynx 4.2 Software Workstation |
| Compliance | Designed to support GLP/GMP workflows with audit trail-capable data acquisition (21 CFR Part 11 readiness via optional software modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-S |
| Instrument Type | Tandem Quadrupole Mass Spectrometer |
| Ionization Compatibility | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., ESCi, UniSpray) |
| Key Technology | StepWave™ Ion Optics, ScanWave™ Collision Cell, RADAR™ Acquisition Mode |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | Xevo TQ-S |
| Configuration | Refurbished System with Full Functional Validation |
| Ionization Compatibility | Electrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., APPI, ESCi) |
| Mass Analyzer Architecture | Three Sequential Quadrupole Stages (Q1 → Collision Cell → Q3) |
| Scan Modes | MRM, Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan, Selected Reaction Monitoring (SRM), RADAR™ Simultaneous Quantitation & Screening |
| Software Platform | MassLynx v4.2 or Later with TargetLynx XS, QuanLynx, and UNIFI Integration Capabilities |
| Regulatory Compliance Support | 21 CFR Part 11 Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework |