| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Arc Premier System |
| Instrument Type | Ultra-High Performance Liquid Chromatography (UHPLC) |
| Application Scope | General-purpose LC platform for metal-sensitive and challenging analytes |
| Key Technology | MaxPeak High-Performance Surface (HPS) |
| Column Compatibility | Optimized for 2.5 µm MaxPeak Premier columns |
| Regulatory Support | Compliant with FDA 21 CFR Part 11, USP <1058>, ISO/IEC 17025, GLP/GMP validation workflows |
| Software Platform | Empower CDS v3/v4, MassLynx MS software |
| Detector Options | TUV, PDA, FLR, ACQUITY QDa, SQD2, Xevo TQS-micro, Xevo TQS-cronos |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoPurification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| UV/Vis Detection | Standard Configurable |
| MS Compatibility | Native HPLC/MS Integration |
| Fraction Collection | Automated, Signal-Triggered (UV, ELSD, MS, Analog) |
| Software Platform | FractionLynx™ |
| Column Technology | Optimized Bed Density (OBD) Columns |
| Scalability | Analytical-to-Preparative Upgrade Path |
| Automation Capability | Unattended Operation |
| Sample Throughput | Multi-hundred-sample Batch Processing |
| Loading Capacity | Milligram-to-Gram Scale Purification |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System |
| Quotation | Upon Request |
| Instrument Type | Time-of-Flight (TOF) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System with ACQUITY Premier |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Software Platform | UNIFI Scientific Information System |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Breeze HPLC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Configuration | Modular Benchtop HPLC Platform |
| Target Users | Academic Teaching Labs, Regulatory QC Laboratories, Early-Stage R&D Facilities |
| Software | Breeze™ Chromatography Data System (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 1525EF |
| Instrument Type | High-Pressure Semi-Preparative HPLC System |
| Application Level | Laboratory-Grade |
| Configuration | Dual-Flow Path Architecture (Analytical + Semi-Prep) |
| Sample Throughput | Single to High-Volume Batch Processing |
| Brand | Waters |
|---|---|
| Model | Breeze2 GPC |
| Origin | USA |
| Instrument Type | Ambient-Temperature SEC System |
| UV Detector Noise | 1.5 × 10⁻⁹ RIU |
| Column Oven Temperature Range | 5 °C above ambient to 60 °C |
| Detection Modes | UV/Vis (2489), Refractive Index (2414) |
| Pump | 1500 Solvent Delivery Module |
| Autosampler | 2707 |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Breeze™ 2 HPLC |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical & Semi-Preparative Use |
| Flow Rate Range | Analytical mode: 0–10 mL/min |
| Semi-preparative mode | 0–22.5 mL/min |
| Maximum Pressure | 6000 psi |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | Analytical: 0.1–100 µL |
| Semi-preparative | 0–10 mL |
| Temperature Control | Optional column oven (configurable per system setup) |
| Wavelength Ranges | UV-Vis detector (2489): 190–700 nm |
| PDA detector (2998) | 190–800 nm |
| Fluorescence detector (2475) | Excitation 200–890 nm, Emission 210–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Charged Aerosol Detector |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | DESI XS |
| Compatibility | SELECT SERIES Cyclic IMS, SYNAPT XS, Xevo G2-XS QTof |
| Ionization Principle | Desorption Electrospray Ionization (DESI) |
| Environmental Sealing | Partially Enclosed Housing |
| Integrated Imaging | Side-View Camera for Spray-Sample Alignment |
| Motion Control | Stepper-Motor Stage with S-Curve Acceleration Algorithm |
| Automation | Auto-shutoff for Solvent Gas & High Voltage |
| Software Integration | HDI™ Software for High-Resolution Mass Spectrometry Imaging |
| Regulatory Context | Designed for GLP/GMP-compliant imaging workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e2695 |
| Instrument Type | Liquid Chromatograph |
| Detector Type | Photodiode Array (PDA) |
| Software | Empower 3 |
| Operational Age | 7 years |
| Warranty | 6 months |
| Compliance Status | Fully Tested and Certified per SpectraLab Scientific Refurbishment Protocol |
| Included Modules | Quaternary Solvent Manager, Sample Manager (Autosampler), Column Heater/Cooler, Degasser, 2998 PDA Detector |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | E2695 |
| Instrument Type | Fast Liquid Chromatography System |
| Maximum Pressure | 34.5 MPa |
| Sample Capacity | 120 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Flow Rate Range | 0.001–10.000 mL/min |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV/Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | Up to 80 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Empower 3 |
| Software Type | Chromatography Data System (CDS) |
| Regulatory Compliance | FDA 21 CFR Part 11, Annex 11, GLP/GMP-ready |
| Architecture | Modular, Scalable, Client-Server & Standalone Deployment Options |
| Instrument Control | ACQUITY UPLC, Alliance HPLC, Third-party HPLC/GC/PDA/MS Systems |
| Database | Embedded Relational SQL Database (Microsoft SQL Server) |
| Integration Capability | LIMS, ERP, ELN, and Enterprise IT Infrastructure |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Investigator SFC System |
| Application Level | Laboratory Grade |
| Instrument Type | Semi-Preparative Supercritical Fluid Chromatography System |
| Flow Rate Range | Up to 15 mL/min |
| Column Capacity | Up to 10 analytical columns or 6 preparative columns |
| Integrated Autosampler | Waters Alias |
| Software Platform | SuperChrom |
| Optional Detectors | 2998 Photodiode Array (PDA) Detector, 2424 Evaporative Light Scattering (ELS) Detector |
| Dimensions (H×L×W) | 92 cm × 98 cm × 68 cm |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ionKey/MS |
| Category | Mass Spectrometry Integrated Microfluidic Separation Platform |
| Compatibility | Designed for Waters Xevo TQ-S, Xevo G2-XS QTof, and other Waters MS platforms with iKey-compatible ion sources |
| Column Format | Monolithic 150 µm ID microfluidic channel packed with 1.7 µm BEH particles |
| Equivalent Chromatographic Performance | Comparable to 2.1 mm ID UPLC columns |
| Sensitivity Enhancement | Up to 5–10× vs. conventional 2.1 mm ID UPLC-MS |
| Solvent Consumption | <5 µL/min typical flow rate |
| Interface Type | Integrated electrospray ionization (ESI) source with embedded heater, e-cord™ electronics, and plug-and-play fluidic/electrical coupling |
| Brand | Waters |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models Supported | TQ Series (TQ-S, TQ-XS, TQ-Xe), 2695 Separations Module, e2695 Separations Module, Acquity UPLC Systems, Arc HPLC Systems, I-Class UPLC Systems, SFC Systems |
| Service Fee Range | USD 1,400–2,800 per incident (excl. parts) |
| Technician Experience | 5–10 years on Waters platforms |
| Response Time | ≤24 hours for emergency support |
| Geographic Coverage | Sichuan, Chongqing, Yunnan, Guizhou |
| Compliance Scope | Supports GLP/GMP-aligned maintenance documentation, ASTM E2500-based verification traceability, and ISO/IEC 17025-compliant service records |
| Software & Data Handling | Compatible with Empower 3, MassLynx, and UNIFI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LC-2695 |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | ~50 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier XE |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Age | 4 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original factory specifications for mass accuracy, resolution, and sensitivity |
| Software | MassLynx 4.1 or later (license transferable per Waters policy) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Ionization Sources | ESI, LockSpray, optional APCI/APPI/ESCI/NanoLockSpray/MUX |
| Mass Analyzer | Orthogonal Acceleration TOF (oa-TOF) |
| Detector | Dual Microchannel Plate (MCP) Assembly |
| Data Acquisition | 4.0 GHz Time-to-Digital Converter (TDC) with Onboard Histogramming |
| Control & Acquisition Software | MassLynx NT 4.x |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Condition | Factory-refurbished, fully tested and validated |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Micromass LCT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Configuration | Orthogonal Acceleration Reflectron TOF |
| Ionization Source | Z-Spray™ Atmospheric Pressure Ionization (API), Nano-ESI & ESI with LockSpray™ |
| Mass Accuracy | ≤5 ppm RMS (with LockSpray calibration) |
| System Integration | Coupled with Waters 2795 HPLC and Waters 2488 Multi-wavelength UV/Vis Detector |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Condition | Fully tested and refurbished by SpectraLab Scientific |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micromass Quattro Micro |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Product Category | Chromatography & Mass Spectrometry |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Included Components | Waters UPLC system, Edwards vacuum pump, full cable set, validated instrument control and data acquisition software (MassLynx v4.1 or later) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Instrument Type | Triple Quadrupole Liquid Chromatography–Tandem Mass Spectrometer (LC/MS/MS) |
| Configuration | UPLC-Coupled |
| Age | 5–7 years |
| Warranty | 6 months |
| Regulatory Compliance | Fully refurbished to meet ISO/IEC 17025-aligned operational standards |
| Software | MassLynx 4.1 or later, with validated acquisition and processing modules |
| Included Hardware | Binary Solvent Manager, Sample Manager with integrated column oven, Acquity PDA detector, Sample Organizer (optional), dedicated PC workstation |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Nano ACQUITY |
| Instrument Type | Liquid Chromatograph (LC) |
| Flow Rate Range | Nanoflow (50–1000 nL/min) |
| Maximum Pressure | 10,000 psi |
| Column Compatibility | Sub-2 µm particles |
| Detector | Acquity 2996 PDA with Nanoflow Flow Cell |
| Software | MassLynx v4.2 or later |
| Warranty | 6 months |
| Operational Age | 4–5 years |
| Compliance | ASTM D7598, USP <621>, ISO/IEC 17025-aligned operation |
| Data Integrity | 21 CFR Part 11-ready configuration (audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoAcquity UPLC + Q-TOF Premier |
| Product Category | Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Included Sources | ESI and Nano-Electrospray Ionization (nESI) with LockSpray™ Calibration Interface |
| Vacuum System | Edwards XDF 35i Turbo Molecular Pump |
| Data System | Lenovo ThinkCentre M58 PC pre-installed with MassLynx 4.1 software |
| UPS | Toshiba Uninterruptible Power Supply (Model UE3G2L036C61T, S/N 050702XXX) |
| UPLC Serial Numbers | EO5NPA-0XXN, EO5NPB-0XXN, EO5NPS-0XXN |
| Q-TOF Serial Number | HAA09X |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported LIMS Software |
| Model | NuGenesis |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | PATROL UPLC |
| Instrument Type | Real-time In-line/At-line UPLC-based PAT System |
| Regulatory Alignment | Designed for FDA QbD and ICH Guidelines |
| Deployment Mode | Integrated Process Analytical Technology (PAT) Platform |
| Operational Architecture | Fully Automated, 24/7 Unattended Operation |
| Diagnostics | On-board Self-Diagnostics with Remote Monitoring Capability |
| Connectivity | Ethernet/IP-enabled for Distributed Control System (DCS) and Manufacturing Execution System (MES) Integration |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and GLP/GMP Data Integrity Requirements |
| Sample Introduction | Configurable for At-line Flow-Through Cells or Direct In-line Probes (with Optional Valving & Filtration Modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 100q SFC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative SFC System |
| Flow Rate Range | Up to 100 mL/min |
| Mobile Phase | CO₂-based supercritical fluid (co-solvent compatible) |
| Fraction Collection | Automated open-loop collection with UV- or MS-triggered modes |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Separation Mode | Chiral and achiral preparative separations |
| Sample Scale | Milligram- to gram-scale purification |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 150 |
| Application Level | Laboratory-grade |
| Instrument Type | High-pressure preparative LC |
| Pump Configuration | Binary or Quaternary (low-pressure solvent selection or high-pressure gradient mixing up to 150 mL/min) |
| Detector Options | 2489 UV/Vis or 2998 Photodiode Array (PDA) |
| Column Compatibility | Up to 50 mm internal diameter |
| Sample Load Range | Milligram- to gram-scale purification |
| Software | ChromScope™ for method development, fraction simulation, and GLP-compliant data handling |
| Compliance | Designed to support 21 CFR Part 11–ready workflows with audit trail and electronic signature capability (when configured with appropriate IT infrastructure) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prep SFC 150 AP System |
| Instrument Type | Preparative |
| Detector Types | None |
| Maximum Pressure | Not Specified |
| Flow Rate Range | Not Specified |