| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PA2000 |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation + Flame Ionization Detection (FID) |
| Regulatory Compliance | HJ 1012–2018 |
| Detection Limit | Sub-ppb (NMHC) |
| Analysis Cycle | As low as 5 seconds |
| Operating Temperature | Full-path high-temperature heating (≥180 °C) |
| Methane Separation Method | High-efficiency catalytic oxidation (≥98% conversion efficiency) |
| Catalyst Lifetime | ≥3 years |
| Oxygen Measurement | Integrated paramagnetic/O₂ sensor |
| Weight | ~13 kg |
| Carrier Gas | Not required |
| Combustion Air | Built-in compressor — no external air supply needed |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RID-2000 |
| Detector Type | Refractive Index Detector (RID) |
| Signal Channels | 2 |
| Compatible System | HPLC |
| Output Modes | Digital Protocol (RS-485/Modbus) & Analog (0–5 V / 4–20 mA) |
| Display | 7-inch Capacitive Touch LCD |
| Light Source | Long-life High-Stability LED |
| Temperature Control | Precision Heated Flow Cell with PID Regulation |
| Leak Detection | Integrated Photoelectric Sensor with Real-time Alert |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | SFJ-16C / SFJ-16D |
| Base Pump | Rotary Vane Vacuum Pump (SFJ-16C) / Scroll Vacuum Pump (SFJ-16D) |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5.0 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 2.5 × 10⁻⁹ Pa·m³/s |
| Maximum Allowable Test Pressure | 1800 Pa |
| Human-Machine Interface | 7-inch Color TFT LCD Touchscreen |
| Leak Port Connection | DN25 KF |
| Dimensions (W×D×H) | 475 × 714 × 1168 mm |
| Power Supply | AC 220 V (±10%), 50/60 Hz |
| Response Time | <1 s |
| Pump-Down/Startup Time | <95 s |
| Detectable Masses | m/z = 2 (H₂), 3 (³He), 4 (⁴He) |
| Ion Source | Dual Filament, Yttria-Coated Iridium, Auto-Switching |
| I/O Interfaces | RS-232, RS-485, LAN, MES Integration Ready |
| Operating Temperature | 0–40 °C |
| Display Languages | English & Chinese |
| Leak Rate Visualization | Numeric Value, Bar Graph, Real-Time Trend Curve |
| Compliance | Designed for ISO 10110-7, ASTM E1003, and JIS Z 2301 aligned workflows |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFJ-16C/D |
| Pricing | Upon Request |
| Base Pump (SFJ-16C) | Rotary Vane Vacuum Pump |
| Base Pump (SFJ-16D) | Scroll Vacuum Pump |
| Minimum Detectable Leak Rate (Helium Mode, Vacuum Method) | 5.0 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Helium Mode, Sniffer Method) | 2.5 × 10⁻⁹ Pa·m³/s |
| Maximum Allowable Test Pressure | 1800 Pa |
| Human-Machine Interface | 7-inch Color LCD Touchscreen |
| Leak Port Flange | DN25 KF |
| Dimensions (W × D × H) | 475 × 714 × 1168 mm |
| Power Supply | AC 220 V (±10%), 50/60 Hz |
| Response Time | <1 s |
| Pump-Down / Startup Time | <95 s |
| Detectable Masses | m/z = 2 (H₂), 3 (³He), 4 (⁴He) |
| Ion Source | Dual Filament, Yttrium Oxide-Coated Iridium, Auto-Switching |
| I/O Interfaces | RS232, RS485, LAN |
| MES Integration | Standard |
| Operating Temperature Range | 0–40 °C |
| Display Languages | English & Chinese |
| Leak Rate Visualization | Numeric, Bar Graph, Real-Time Trend Curve |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SG1500 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Baseline Stability | ±2% FS over 24 h |
| Measured Gases | SO₂, NO, O₂, NOₓ, NH₃ |
| Optional Extension | CO₂ |
| Operating Temperature Range (Sampling Path) | Up to 180 °C |
| Display | 7″ Color TFT Touchscreen |
| Data Output | USB Export (1-min & 5-min Averaged Reports), Optional Thermal Printer Support |
| Compliance Features | Built-in Humidity Sensor (wet-to-dry basis conversion), Automatic Leak Check, Flow & Pressure Compensation, Dual-Range Selection for SO₂/NOₓ, Real-time Trend Plotting, GLP-Compliant Audit Trail Logging |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOF2000 |
| Instrument Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOF-MS) |
| Configuration | Online Fixed/Mobile Deployment |
| Response Time | Sub-second (≤1 s) |
| Analyte Capacity | >300 Atmospheric Volatile Organic Compounds (VOCs) |
| Mass Resolution | >2000 FWHM (Toluene) |
| Linear Dynamic Range | 4 orders of magnitude |
| Vacuum System | Turbo-molecular pump cascade (3-stage) + backing mechanical pump |
| Ionization Source | 10.8 eV VUV lamp (soft ionization) |
| Mass Analyzer | Orthogonal acceleration reflectron TOF with second-order spatial and energy focusing |
| Detection Mode | Direct ambient sampling, no pre-concentration or chromatographic separation required |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TQ9200 |
| Instrument Type | Triple Quadrupole (Tandem QqQ) Mass Spectrometer |
| Application Scope | Universal (Broad-Spectrum Quantitative & Qualitative Analysis) |
| LC Component | WAYEAL LC3600 Ultra-High-Performance Liquid Chromatograph |
| Ionization Source | Electrospray Ionization (ESI), Standard Configuration |
| Vacuum Interface | High-Durability Conical Interface with Active Desolvation |
| Detection Mode | Multiple Reaction Monitoring (MRM), Selected Reaction Monitoring (SRM), Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | UV Detector |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Chromatographic Detector |
| Wavelength Range | 188–900 nm |
| Light Source | Deuterium Lamp (Dual-Lamp Holder: D₂ + Tungsten) |
| Wavelength Accuracy/Reproducibility | ≤ ±0.1 nm |
| Flow Cell Design | Low-Dead-Volume Optimized Optical Flow Cell with Precision-Polished Light Path |
| Detection Modes | Dual-Wavelength Simultaneous Detection, Full-Spectrum Scanning (188–900 nm), Auto Spectral Calibration |
| Leak Detection | Integrated Optical Leak Sensor with Audible/Visual Alarm |
| Compliance | Designed to Support GLP/GMP Data Integrity Requirements (Audit Trail, User Access Control, Electronic Signature Ready) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1700 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Target Analytes | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and selected BTEX compounds |
| Sample Path Temperature | 175 °C (fully heated from probe to detector) |
| Compliance | Certified by China National Environmental Monitoring Centre (CNEMC) for CEMS applicability testing |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1750 |
| Instrument Principle | Cryogenic Preconcentration Coupled with Gas Chromatography–Mass Spectrometry (GC-MS) |
| Configuration | Online Continuous Monitoring System |
| Response Time | ≤5 s (T90) |
| Target Analytes | 116 VOCs including PAMS, TO-14/TO-15 compounds, and C1–C10 aldehydes & ketones |
| Detection Capability | Sub-ppt (pg/m³) level quantification |
| Detector Configuration | Dual-channel detection via Flame Ionization Detector (FID) and Quadrupole Mass Spectrometer (MS) |
| Sample Introduction | Automated, unattended, real-time ambient air sampling |
| Surface Treatment | Fully passivated gas pathways (SilcoNert® or equivalent inert coating) |
| Compliance Readiness | Designed to support EPA Method TO-14A, TO-15, ASTM D5504, and ISO 16017-1 workflows |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WMS1800 |
| Pricing | Available upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WMS1800x |
| Pricing | Available upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | WS1503 |
| Price Range | USD 7,000 – 14,000 |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WS1504 |
| Pricing | Available upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WS1505 |
| Pricing | Upon Request |
| Measurement Method | Alkaline Potassium Persulfate Digestion – UV Spectrophotometry |
| Measurement Range | 0–200.0 mg/L (expandable) |
| Accuracy | ±5% |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer | WAYEAL Instrument Co., Ltd. |
| Model | WS1801 |
| Instrument Type | Online Automatic Water Sampler |
| Sampling Method | Exceedance-triggered Retention Sampling |
| Single Sample Volume | 10 mL to 1000 mL |
| Sampling Volume Accuracy | ±7% (at 200 mL retention volume) |
| Sampling Interval | Adjustable from 1 min to 9999 min |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | WS1501 |
| Pricing | Available Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WS1506 |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Online Analyzer |
| Range | 0–25.0 mg/L (expandable) |
| Repeatability | ≤5% RSD |
| Accuracy | ±10% of reading |
| LOD | ≤1.5 mg/L |
| Resolution | 0.01 mg/L |
| Single Analysis Time | 30–9999 min |