YST
Filter
Showing all 17 results
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN2000 mm |
| Flow Velocity Range | 0.1–15 m/s |
| Minimum Fluid Conductivity | ≥5 μS/cm |
| Accuracy Class | ±1.0% of reading |
| Lining Materials | PTFE or rubber (selectable) |
| Electrode Materials | 316L stainless steel or Hastelloy (selectable) |
| Rated Working Pressure | ≤0.6 MPa |
| Temperature Range | –20 to +60 °C (rubber lining) |
| Protection Rating | IP65 (IP68 optional) |
| Power Supply | AC 220 V / DC 24 V |
| Output Signals | 4–20 mA analog output |
| Connection | Flanged, compliant with GB/T 11988 |
| Straight Pipe Requirements | ≥5DN upstream, ≥2DN downstream |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN25 mm |
| Lining Material | F46 (Fluorinated Ethylene Propylene, FEP) |
| Flow Range | 0.01–6 m³/h |
| Nominal Pressure | 1.6 MPa |
| Medium Temperature | −40 °C to +180 °C (remote transmitter configuration) |
| Ambient Temperature | −25 °C to +60 °C |
| Minimum Conductivity | ≥20 µS/cm |
| Sensor Protection Rating | IP65 |
| Accuracy | ±0.5% of Full Scale (FS) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL (DN50) |
| Nominal Pipe Size | DN50 (50–55 mm ID, adjustable insertion depth) |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range (full pipe, DN50) | 0.000785–0.0785 m³/h |
| Accuracy | ±0.5% FS (standard conditions), ±1.0% FS (challenging conditions, e.g., low-conductivity or particulate-laden fluids) |
| Minimum Fluid Conductivity | ≥5 µS/cm |
| Operating Temperature | –20°C to +150°C |
| Max Working Pressure | 1.6 MPa |
| Electrode Materials | 316L stainless steel (standard), Hastelloy C-276 (corrosive media), Titanium (ultra-pure applications) |
| Lining Materials | PTFE (chemical resistance, high-temp), Neoprene rubber (abrasion resistance, wastewater) |
| Output Signals | 4–20 mA DC (analog), RS485 (Modbus RTU) |
| Power Supply | 220 V AC or 24 V DC |
| Sensor Protection Rating | IP65 (indoor/outdoor non-submersible), optional IP68 (submersible) |
| Ambient Operating Conditions | –25°C to +60°C, ≤95% RH (non-condensing) |
| Long-Term Drift | ≤0.1% FS/year |
| Repeatability | ≤0.2% FS |
| Excitation Method | Low-frequency rectangular wave magnetic excitation |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Pipe Size Range | DN10–DN3000 |
| Flow Velocity Range | 0.1–10 m/s |
| Accuracy | ±0.5% FS (standard), ±1.0% FS (challenging conditions) |
| Operating Pressure | PN1.0 MPa / PN1.6 MPa (customizable) |
| Medium Temperature | −20°C to +180°C (standard liner) |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316L stainless steel, Hastelloy C, titanium |
| Liner Materials | PTFE, neoprene, polyurethane |
| Output Signals | 4–20 mA analog, RS485 (Modbus RTU) |
| Sensor Protection Rating | IP67/IP68 |
| Converter Protection Rating | IP65 |
| Power Supply | AC 220 V ±10% 50/60 Hz or DC 24 V ±10% |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN800 |
| Measurement Principle | Faraday’s Law of Electromagnetic Induction |
| Flow Velocity Range | 0.01–10 m/s |
| Accuracy | ±0.5% FS (optional ±1.0% FS) |
| Medium Conductivity | ≥5 µS/cm |
| Temperature Range | –20 to +180 °C (dependent on liner material) |
| Pressure Rating | 0.6–4.0 MPa |
| Liner Material | PTFE |
| Electrode Material | 316L Stainless Steel |
| Enclosure Protection | IP65 |
| Output Signals | 4–20 mA analog, pulse output |
| Communication Interface | RS485 (Modbus RTU) |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Wetted Materials Compliance | FDA-compliant PTFE liner per ASTM D1711 |
| Electromagnetic Compatibility | IEC 61326-1 (Industrial Environment) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN250 |
| Measurement Principle | Faraday’s Law of Electromagnetic Induction |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range | 17.66–176.25 m³/h |
| Accuracy Class | ±0.5% of reading |
| Turndown Ratio | 100:1 |
| Minimum Conductivity | ≥5 µS/cm |
| Max. Working Pressure | 1.6 MPa |
| Process Temperature Range | –20°C to +80°C (standard) |
| Ambient Temperature Range | Sensor: –40°C to +80°C |
| Converter | –15°C to +50°C |
| Enclosure Rating | IP65 (integrated unit) |
| Output Signals | 4–20 mA (load ≤750 Ω), RS485 with Modbus RTU protocol |
| Power Supply | 220 VAC ±10%, 50 Hz ±1 Hz or 24 VDC ±10% |
| Lining Material | PTFE (polytetrafluoroethylene) |
| Electrode Material | 316L stainless steel (customizable) |
| Connection | GB/T 9119–2010 flanged (equivalent to EN 1092-1/DIN 2501/ANSI B16.5 Class 150) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN40 |
| Flow Range | 0.5–50 m³/h |
| Accuracy | ±0.3% of reading (flow velocity ≥1 m/s) |
| Minimum Conductivity | ≥5 µS/cm |
| Nominal Pressure | 4.0 MPa |
| Operating Temperature | Sensor: −25°C to +60°C |
| Converter/Integral Unit | −10°C to +60°C |
| Lining Material | PTFE (Polytetrafluoroethylene) |
| Electrode Material | Stainless Steel 0Cr18Ni12Mo2Ti |
| Protection Rating | IP65 |
| Output Signals | 4–20 mA analog output |
| Compliance Standard | JB/T 9248–1999 |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Pipe Size | DN50 (50–55 mm ID) |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range (DN50 full pipe) | 0.000785–0.0785 m³/h |
| Accuracy | ±0.5% FS (standard conditions), ±1.0% FS (with suspended solids) |
| Conductivity Requirement | ≥5 μS/cm |
| Operating Temperature | −20°C to +150°C (medium), −25°C to +60°C (ambient) |
| Max Working Pressure | ≤1.6 MPa |
| Electrode Materials | 316L stainless steel (standard), Hastelloy C-276, titanium |
| Lining Materials | PTFE (acid/alkali/heat resistant), chloroprene rubber (abrasion resistant, for wastewater) |
| Output Signals | 4–20 mA DC analog, RS485 Modbus RTU |
| Power Supply | 220 V AC or 24 V DC |
| Enclosure Rating | IP65 (standard), IP68 (optional, submersible) |
| Relative Humidity | ≤95% RH (non-condensing) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST305D150BF223 |
| Nominal Pipe Size | DN150 (150 mm ID ±5 mm) |
| Flow Velocity Range | −10 to +10 m/s |
| Accuracy | ±1.0% FS (dual-path), Repeatability: ≤0.2% |
| Operating Temperature | Sensor −40–+160 °C |
| Power Supply | AC 220 V ±10% (50/60 Hz) or DC 24 V ±10%, ≤10 W |
| Output/Communication | RS485 Modbus-RTU (standard), NB-IoT optional |
| Protection Rating | Sensor IP68, Transmitter IP65 |
| Display | Backlit Chinese LCD showing real-time flow rate, totalized flow, and temperature |
| Medium Compatibility | Municipal wastewater, potable water, and other homogeneous liquids (pH 4–9) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YST108B-NTU680T80 |
| Price | USD 350 (FOB) |
| Turbidity Range | 0–1000 NTU |
| Sludge Concentration Range | 0–50 g/L (expandable) |
| Accuracy | ±2.5% FS |
| Light Source | 860 nm IR LED (compliant with ISO 7027) |
| Ingress Protection | IP67 |
| Power Supply | AC 220 V ±10% or DC 24 V (solar-compatible) |
| Output Signals | 4–20 mA analog + RS485 Modbus RTU |
| Operating Temperature | −10 °C to +60 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Installation Options | Submersible or inline |
| Cable Length | Up to 50 m (remote sensor design) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST108B-NTU680T |
| Measurement Range | 0–1000 NTU |
| Accuracy | ±2% FS |
| Detection Principle | 90° Nephelometric Scattering (ISO 7027 Compliant) |
| Response Time | ≤10 s |
| Power Supply | AC 220 V / DC 24 V (wide-input) |
| Output Signals | 4–20 mA analog + RS485 (Modbus RTU) |
| Ingress Protection | IP65 |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Display | Backlit LCD with real-time NTU, temperature, calibration status, and power indicator |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST305D80BF223 |
| Pipe Size | DN80 |
| Flow Velocity Range | 0.01–15 m/s |
| Accuracy | ±0.5% of reading (v ≥ 0.3 m/s), ±1.0% of reading (0.1 ≤ v < 0.3 m/s) |
| Repeatability | ≤ ±0.2% |
| Medium | Single-phase liquid with ≤1% suspended solids, viscosity ≤1000 cP |
| Sensor Operating Temperature | −40°C to +80°C |
| Converter Operating Temperature | −20°C to +60°C |
| Humidity | ≤95% RH (non-condensing) |
| IP Rating | IP65 |
| Output | 4–20 mA DC (load ≤750 Ω), pulse (0–1000 Hz, 50% duty cycle) |
| Communication | RS485 Modbus-RTU |
| Power Supply | AC 220 V ±10% (50/60 Hz) or DC 24 V ±15% |
| Power Consumption | ≤15 W |
| Wetted Materials | Carbon steel spool body, GB/T 9119 flanges, piezoelectric ceramic transducers |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST305D80BF223 |
| Measurement Principle | Transit-Time Ultrasonic Method |
| Accuracy | ±1% of reading |
| Repeatability | <0.5% |
| Flow Velocity Range | 0 to ±10 m/s |
| Volumetric Flow Range (Water) | 5–500 m³/h |
| Turndown Ratio | 1:200 |
| Pipe Diameter Compatibility | DN15–DN3000 |
| Acceptable Pipe Materials | Steel, stainless steel, cast iron, PVC (with or without lining) |
| Fluid Compatibility | Single-phase, acoustically conductive liquids (e.g., potable water, seawater) |
| Fluid Temperature Range | −30 °C to +160 °C |
| Fluid Turbidity Limit | ≤10,000 ppm |
| Air Bubble Tolerance | Low |
| Operating Ambient Temperature (Transmitter) | −20 °C to +60 °C |
| Humidity Limit | ≤85% RH |
| Sensor Immersion Rating | IP68, submersible up to 2 m depth |
| Output Signals | 4–20 mA (load ≤1 kΩ, accuracy 0.1%), OCT pulse output |
| Communication | RS485, Modbus RTU protocol |
| Power Supply | DC 8–36 V |
| Power Consumption | 1.5 W |
| Data Retention | Non-volatile memory with battery backup |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST305D150BF223 |
| Nominal Diameter | DN150 (150 mm) |
| Pressure Rating | PN 1.0 / 1.6 MPa (customizable to 2.5 MPa) |
| Accuracy Class | Class 2 (Q₃ ≤ Q ≤ Q₄), Class 3 (Q₁ ≤ Q < Q₃) |
| Turndown Ratio | 1:100 (Q₁ = 0.03 m³/h, Q₄ = 3 m³/h) or 1:200 (Q₁ = 0.015 m³/h, Q₄ = 3 m³/h) |
| Flow Velocity Range | 0.01–3 m/s |
| Operating Temperature | Cold water type: −20°C to +50°C |
| Hot water type | 0°C to +90°C (customizable higher) |
| Ambient Humidity | ≤95% RH (non-condensing) |
| Outdoor version | ≤90% RH (short-term rain resistance) |
| Power Supply | Standard 3.6 V Li-SOCl₂ battery (2.4 Ah) |
| Communication | Standard RS485 (Modbus-RTU) |
| Enclosure Rating | Body IP65 |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST305D20BF223 |
| Nominal Diameter | DN200 mm |
| Flow Range | 22–1100 m³/h (0.1–10.0 m/s) |
| Accuracy | ±0.5% FS |
| Repeatability | ≤0.1% FS |
| Operating Temperature | −25 °C to +60 °C |
| Max Working Pressure | ≤1.6 MPa |
| Pipe Material Compatibility | Carbon Steel, Stainless Steel, PVC |
| Output Signals | 4–20 mA analog, RS485 Modbus RTU |
| Enclosure Rating | IP65 |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST940M-3CY10 |
| Measurement Principle | Non-contact ultrasonic time-of-flight (TOF) |
| Flow Range | 0.01–10,000 m³/h (channel-dependent) |
| Velocity Range | 0.01–5.0 m/s |
| Level Range | 0.02–3.0 m (customizable) |
| Velocity Accuracy | ±1.0% FS |
| Level Accuracy | ±0.5% FS |
| Flow Accuracy | ±2.0% FS (standard rectangular/trapezoidal channels) |
| Operating Temperature | −20 °C to +60 °C |
| Storage Temperature | −30 °C to +70 °C |
| Humidity | ≤95% RH (non-condensing) |
| Sensor IP Rating | IP68 |
| Transmitter IP Rating | IP65 |
| Analog Outputs | 4–20 mA, 0–10 V |
| Digital Output | RS485 (Modbus RTU) |
| Relay Outputs | 2-channel (configurable for alarm/control) |
| Power Supply | AC 220 V ±10% / 50 Hz or DC 24 V ±10% |
| Data Storage | ≥1 year (1 record/hour), USB/RS485 export supported |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST809B-DO660 |
| Measurement Range | 0.00–20.00 mg/L DO |
| Accuracy | ±0.5% FS |
| Fluorescent Cap Lifetime | ≥12 months (typical operation) |
| Temperature Compensation | Automatic, 0–50 °C |
| Enclosure Rating | IP68 |
| Communication Interface | RS485 |
| Power Supply | AC 220 V or DC 12 V (solar-compatible) |
| User Interface | Chinese LCD, one-button calibration |
