Yuntang
Filter
Showing 1–30 of 63 results
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-THm |
| CO₂ Range | 0–5000 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Accuracy | ±3 ppm |
| Temperature Range | −20 to 80 °C |
| Temperature Accuracy | ±0.2 °C |
| Relative Humidity Range | 0–85 %RH |
| RH Accuracy | ≤±1 %RH |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| PAR Accuracy | <±1 µmol·m⁻²·s⁻¹ |
| Flow Rate (Mechanical) | 0–1.5 L/min (±1% full scale |
| Flow Rate (Optional Electronic) | 0–1 L/min, Resolution: 0.0001 L/min |
| Chamber Dimensions | Ø110 mm × 200 mm (customizable) |
| Operating Environment | −20 to 60 °C, 0–85 %RH (non-condensing) |
| Battery | 8.4 V DC Li-ion, 10 h continuous operation |
| Data Storage | 16 GB internal (expandable to 32 GB) |
| Display | 3.5″ TFT color LCD, 800×480 px |
| Interface | USB for direct data export |
| Weight | 3.25 kg (main unit) |
| Optional | Soil moisture & temperature probe |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | FERRITE-CHECK 140 / FERRITE-CHECK 240 |
| Price Range | USD 4,200 – 5,350 |
| Measurement Principle | Magnetic Induction |
| Standards Compliance | DIN EN ISO 8249:2018, Basel Convention referenced for calibration traceability |
| Measurement Range | 0.2–100 Fe% / 0.2–140 FN |
| Resolution | 0.1 Fe% or FN |
| Accuracy | ±<5% of reading |
| Minimum Test Area | Ø2 mm |
| Operating Temperature | 0–50 °C |
| Display | 320×480-pixel color LCD touchscreen |
| Data Storage | 10,000 measurements (segmented) |
| Battery Life | ~25 h (3×AA alkaline) |
| Power Options | USB-C external supply |
| Dimensions | 150 × 85 × 35 mm |
| Weight | 320 g (with batteries) |
| Communication | Bluetooth 5.0 (Android/iOS/Windows), USB-C, SCPI-compliant remote interface |
| Software | Lima Connect (free Windows application with statistical analysis and graphical export) |
| Calibration Standards | Three NIST-traceable ferrite reference standards included |
| Language Support | English, German, French, Italian, Spanish |
| IP Rating | Not specified (rubberized protective sleeve provided) |
| Probe Type | Digital Ferrite-2000 sensor with high-sampling-rate digitization |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC-R1 |
| Product Category | Natural Gas Analyzer |
| Dimensions | 540 × 390 × 360 mm (L×W×H) |
| Power Supply | AC 220 V |
| Column Oven Temperature Range | 5 °C above ambient to 200 °C (±0.1 °C stability) |
| Carrier Gas | Ultra-High-Purity Hydrogen (≥99.995%) |
| Detector | Thermal Conductivity Detector (TCD), Sensitivity ≥3000 mV·mL/mg (benzene), Noise ≤0.02 mV |
| Retention Time Precision | ≤0.02 min |
| Quantitative Repeatability | RSD ≤1% |
| Sample Compatibility | LPG, LNG, CNG, coalbed methane, shale gas, biogas, refinery off-gas, coke oven gas, blast furnace gas, and pipeline natural gas |
| Output Parameters | Methane, Ethane, Propane, n-Butane, i-Butane, Pentanes (n-/i-), C6+, CO₂, N₂, O₂, H₂, CO, DME, methanol, ethylene, propylene, butenes, Wobbe Index, Gross/Net Calorific Value (MJ/m³), Density, Relative Density, Combustion Potential |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | RT-200 |
| Price Range | USD 560 – 920 |
| Measurement Principle | Inductive Contact Profilometry (Stylus-Based) |
| Display | 128×64 OLED Dot-Matrix |
| Battery | Rechargeable Li-ion, >20 h Continuous Operation |
| Data Storage | 100 Sets (Raw Profile + Parameters) |
| Compliance | ISO 4287, ISO 4288, DIN EN ISO 3274, ANSI B46.1, JIS B 0601, JIS B 0611 |
| Measured Parameters | Ra, Rz, Rq, Rt, Rp, Rv, R3z, R3y, RzJIS, Rsk, Rku, Rsm, Rmr |
| Sampling Length | 0.25 mm / 0.8 mm / 2.5 mm (Auto-selectable per standard) |
| Cutoff Wavelength | λc = 0.25 / 0.8 / 2.5 mm |
| Vertical Resolution | 0.01 µm |
| Traverse Speed | 0.5 mm/s (standard), 0.1–1.0 mm/s adjustable |
| Stylus Tip Radius | 5 µm (diamond, 90° included angle) |
| Force | 4 mN (standard), 0.75–15 mN programmable |
| Interface | USB 2.0 (for PC communication & firmware update) |
| Optional Accessory | Thermal Printer Module |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-30L |
| Price Range | USD 680–740 |
| Measurement Range | 30 mL/min – 30 L/min |
| Accuracy | ±1% or better |
| Timing Range | 0.1–1200.0 s |
| Timing Resolution | 0.001 s |
| Power Supply | 8.4 V / 1200 mAh Rechargeable Li-ion Battery |
| Charge Cycles | >500 |
| Standby Time | >300 h |
| Operating Temperature | 0–55 °C |
| Weight | ~1500 g |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | YT-321 |
| Price | USD 170 (FOB) |
| Measurement Principle | Pulse-Echo Ultrasonic |
| Range (Steel) | 0.75–350 mm |
| Standard Probe Range | 1–250 mm |
| Resolution | 0.1 mm |
| Sound Velocity Adjustment | 1000–9999 m/s |
| Operating Temp. | −10 to +60 °C |
| Accuracy | ±(1% H + 0.1) mm (H = actual thickness) |
| Power | Two AAA alkaline batteries |
| Battery Life | ~200 hours |
| Dimensions | 130 × 70 × 25 mm |
| Weight | 0.2 kg (instrument only) |
| Display | High-brightness LED backlight |
| Compliance | Designed per ISO 2400:2019 (Ultrasonic thickness measurement — Calibration and verification procedures) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-600A |
| Measurement Range | 2–500 mN/m |
| Accuracy | ±0.4 mN/m |
| Sensitivity | 0.1 mN/m |
| Detection Method | Du Noüy Ring Method |
| Power Supply | AC 220 V ±5%, 50 Hz ±2.5% |
| Power Consumption | 50 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Temperature Control | PID Auto-Tuning |
| Sample Capacity | 3 positions |
| Display | High-Resolution Color Touchscreen |
| Data Output | Auto-printing & Real-time Dynamic Tension Curve Visualization |
| Calibration | Single-Point Calibration Protocol |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-610 |
| Magnetization Modes | AC Circumferential (0–2000 A, continuously adjustable with phase-controlled power-off) |
| Longitudinal Magnetization Force | AC 0–24,000 AT, continuously adjustable with phase-controlled power-off |
| Magnetization Configurations | Circumferential, Longitudinal, or Composite |
| Powder Application Method | Dry Powder |
| Demagnetization Residual Field | ≤0.2 mT |
| Inspection Cycle Time | 6 seconds per component |
| Continuous Operating Duration | >4 hours |
| Structural Design | Hand-Carried Yoke Configuration |
| Primary Application Sector | Rail Transportation Infrastructure |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-610C |
| Magnetization Modes | Circumferential (AC 0–2000 A, phase-controlled cutoff), Longitudinal (AC 0–24,000 AT, phase-controlled cutoff), Composite |
| Configuration | Portable, Handheld Yoke System |
| Magnetization Method | Dry Powder MPI |
| Circumferential Magnetizing Current | AC 0–2000 A, continuously adjustable with phase-angle control for precise demagnetization timing |
| Longitudinal Magnetomotive Force | AC 0–24,000 AT, continuously adjustable with phase-angle control |
| Inspection Cycle Time | ≤6 seconds per component |
| Residual Field After Demagnetization | ≤0.2 mT |
| Continuous Operating Duration | >4 hours |
| Input Voltage | AC 220 V ±10% |
| Output Voltage | AC 36 V (safety-isolated) |
| Output Current | >10 A |
| Lifting Power | ≥5 kg (AC), ≥18 kg (DC for optional probes) |
| Duty Cycle | 50% |
| Sensitivity Verification | Clear indication of ASTM E1444-compliant A1-30/100 shim test piece |
| Dimensions (H×W×D) | 230 × 160 × 120 mm |
| Weight | 5 kg |
| Probe Compatibility | Standard A-type yoke (adjustable pole spacing 0–250 mm), optional E-type (cross-yoke), D-type (high-lift yoke), O-type (circular coil, Φ150 mm, 1800 TA) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-610C |
| Magnetization Modes | Circumferential (AC 0–2000 A, phase-controlled cutoff), Longitudinal (AC 0–24,000 AT, phase-controlled cutoff), Composite |
| Inspection Cycle Time | ≤6 s per part |
| Residual Field After Demagnetization | ≤0.2 mT |
| Continuous Operating Duration | >4 h |
| Input Voltage | AC 220 V ±10% |
| Output Voltage | AC 36 V |
| Output Current | >10 A |
| Lifting Force | ≥5 kgf |
| Duty Cycle | 50% |
| Sensitivity | Clear indication of ASTM E1444/E709 A1-30/100 shims |
| Probe Configurations | Electromagnetic Yoke (adjustable pole spacing: 0–250 mm), Horseshoe Probe (0–160 mm), Circular Coil (Φ150 mm, 1800 TA) |
| Dimensions (L×H×W) | 230×160×120 mm |
| Weight | 5 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | YT-BCMn |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Field-Deployable Laboratory Analyzer |
| Range | 0.25–25 mg/L (multi-range auto-switching) |
| Repeatability | <0.5% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.4 mg/L |
| Resolution | 0.001 mg/L |
| Compliance | GB/T 11892–1989 |
| Display | 8″ HD TFT touchscreen (1024×768) |
| OS | Android 7.1.1 |
| Power | 48 V / 8 Ah Li-ion battery (≥6 h continuous dual-mode operation) |
| Dimensions | 430 × 350 × 200 mm |
| Weight | 11 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YT-BOD |
| Instrument Type | Portable BOD Analyzer |
| Measurement Principle | Mercury-Free Pressure Differential Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 5 mg/L |
| Accuracy | ≤5% or ±1 mg/L (at 3.55 hPa) |
| Single-Sample Measurement Time | 8 min |
| Repeatability | 3% |
| Resolution | 0.01 mg/L |
| Data Logging Interval | 5 min – 24 h (user-configurable) |
| Incubation Temperature | 20 ± 1 °C |
| Incubation Duration | 1–30 days (programmable) |
| Sample Vessel Volume | 580 mL |
| Number of Parallel Channels | 6 independent terminals |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Dimensions (w×d×h, incl. bottles) | 324 × 335 × 350 mm |
| Data Storage Capacity | ≥10 years of measurement records |
| Connectivity | Bluetooth (terminal-to-host), Wi-Fi (cloud upload), USB export |
| Built-in Thermal Printer | Yes |
| Operating System | Android-based UI |
| Display | 7-inch capacitive touchscreen |
| Battery Life (per terminal) | >2 years |
| Compliance Standards | HJ 505–2009, JJG 824–1993 |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-CSL |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3 kW |
| Dimensions (L×W×H) | 770×460×410 mm |
| Sample Capacity | 1–15 samples per run (continuous loading enabled) |
| Sulfur Measurement Range | 0–40 wt% |
| Combustion Time per Sample | ~5–7 min (including 45 s at 500 °C and 4 min 45 s at 1050 °C) |
| Temperature Control Accuracy | ±5 °C |
| High-Temperature Zone | ≥90 mm length, stabilized at 1050 °C ±5 °C |
| Thermocouple Class | 0.5 |
| Electrolytic Cell Volume | 450 mL |
| Platinum Electrode Area | 150 mm² |
| Heating Rate | 20–25 °C/min (reaches 1050 °C in ~30 min) |
| Repeatability (St,ad) | ≤0.05% (St <1%), ≤0.10% (1%≤St≤4%), ≤0.20% (St >4%) |
| Reproducibility (St,d) | ≤0.10% (St <1%), ≤0.20% (1%≤St≤4%), ≤0.30% (St >4%) |
| Temperature Compensation | Automatic |
| Data Storage | Permanent digital archive with query & print capability |
| Multi-PC Data Sharing | Supported |
| Safety Protections | Silicon Carbide Tube Auto-Protection, Overcurrent Protection |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-CSL· |
| Detection Principle | Coulometric Titration (ASTM D3177, ISO 351, GB/T 214-2007) |
| Sulfur Range | 0–40 wt% |
| Sample Capacity | 1–15 samples per batch (continuous loading enabled) |
| Analysis Time | ~5–7 min per sample |
| Furnace Temp Control | 1050 °C ±5 °C (adjustable), High-Temp Zone ≥90 mm |
| Heating Element | Silicon Carbide Tube |
| Electrolytic Cell Volume | 450 mL |
| Pt Electrode Area | 150 mm² |
| Temp Sensor Accuracy | Class 0.5 |
| Repeatability | ≤0.05% (St <1%), ≤0.10% (1%≤St≤4%), ≤0.20% (St>4%) |
| Reproducibility | ≤0.10% (St <1%), ≤0.20% (1%≤St≤4%), ≤0.30% (St>4%) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤3 kW |
| Dimensions (L×W×H) | 770×460×410 mm |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-D-12 |
| Heating Zones | 3 (Headspace Oven, Transfer Line, Six-Port Valve) |
| Temperature Range (Headspace Oven) | Ambient to 260 °C (1 °C adjustable increment) |
| Temperature Range (Transfer Line & Valve) | Ambient to 220 °C (1 °C adjustable increment) |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 12 × 10 mL or 20 mL vials |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Precision (RSD) | <1.5% for 200 ppm ethanol in water |
| Power Consumption | 1000 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 420 mm × 180 mm × 500 mm |
| Weight | ~17.5 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-DB |
| Wavelength Range | 950–1650 nm |
| Sample Form | Solid granules, powders, or forage |
| Measurement Time | 1–3 min per sample |
| Sample Chamber Capacity | 600 mL |
| Dimensions (L×W×H) | 30 × 27 × 23 cm (including sample chamber) |
| Weight | 6 kg |
| Display | 10-inch color touchscreen |
| Power Supply | 12 V / 4 A |
| Battery Operation | Optional external battery (5 h runtime) |
| Operating Temperature | 5–45 °C |
| Compliance | Designed for routine QC in food, feed, and grain supply chains per ISO 12099, AOAC 984.27, and USP <1119> NIRS guidelines |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-DL9 |
| Price | USD 495 (FOB) |
| Test Range | Up to 8,000 m |
| Minimum Blind Zone | 0 m |
| Distance Resolution | 0.5 m |
| Pulse Width | 96 ns – 10 µs (auto-adjustable) |
| Fault Resistance Range | 0–0.5 MΩ |
| Depth Detection Capability | ≥3 m |
| Path Tracing Accuracy | ≤0.2 m |
| Signal Frequency | 1 kHz (adjustable) |
| Display | 480×800 TFT color LCD |
| Battery Life | 6–8 h (Li-ion) |
| Dimensions (W×D×H) | 220×160×90 mm |
| Weight | 2.0 kg |
| Integrated Multimeter | AC/DC voltage, insulation resistance, loop resistance |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | YT-DP |
| Price Range | USD 8,400 – 9,500 |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288, quad-core, 1.88 GHz |
| Measurement Time | ≤17 seconds per egg |
| Power Supply | DC 12 V (standard), optional 6 Ah rechargeable Li-ion battery |
| Connectivity | Wi-Fi, RJ45 Ethernet, USB data export |
| Data Storage | On-device + cloud/platform upload |
| Printing | Integrated thermal printer with QR code, sampling & testing metadata |
| Dimensions | 340 × 290 × 238 mm (L×W×H) |
| Weight | 5.05 kg |
| Albumen Height Range | 0.0–40.0 mm (±0.1 mm) |
| Egg Mass Range | 0–250 g (±0.1 g) |
| Haugh Unit Range | 0–130 HU |
| Shell Thickness Range | 0.00–4.00 mm (±0.01 mm) |
| Egg Grade Classification | AA (≥72), A (71–60), B (59–31), C (≤30) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YT-DP |
| Price Range | USD 8,400 – 9,500 |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288, quad-core, 1.88 GHz |
| Measurement Time | ≤17 seconds per egg |
| Power Supply | DC 12 V (standard), optional 6 Ah rechargeable Li-ion battery |
| Connectivity | Wi-Fi, RJ45 Ethernet, USB data export |
| Data Storage | On-device + cloud/platform upload |
| Printing | Integrated thermal printer with QR code, sampling ID, audit trail fields |
| Shell Thickness Range | 0.00–4.00 mm (0.01 mm resolution) |
| Albumen Height Range | 0.0–40.0 mm (0.1 mm resolution) |
| Egg Weight Range | 0–250 g (0.1 g resolution) |
| Haugh Unit Range | 0–130 HU |
| Egg Grade Classification | AA (≥72), A (60–71), B (31–59), C (≤30) |
| Dimensions | 340 × 290 × 238 mm (L×W×H) |
| Net Weight | 5.05 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-DP |
| Display | 7-inch Android-based touchscreen (ARM Cortex-A7, RK3288 quad-core, 1.88 GHz) |
| Measurement Speed | ≤17 seconds per egg |
| Weight Range | 0–250 g (0.1 g resolution) |
| Albumen Height Range | 0.0–40.0 mm (0.1 mm resolution) |
| Haugh Unit Range | 0–130 HU |
| Eggshell Thickness Range | 0.00–4.00 mm (0.01 mm resolution) |
| Colorimetric Measurement | Yellowness index (non-contact digital color sensor) |
| Data Storage | On-device memory + USB export + Wi-Fi/RJ45 network upload |
| Power Supply | DC 12 V (standard) |
| Dimensions | 340 × 290 × 238 mm (L×W×H) |
| Net Weight | 5.05 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-GB3. |
| Detection Principle | Competitive Immunoassay (Colloidal Gold Immunochromatography) |
| Detection Target | Benzo[a]pyrene (BaP) |
| Sample Matrix | Edible oils, sesame oil |
| Limit of Detection (LOD) | 10.0 µg/kg |
| Display | 10.1-inch capacitive touchscreen |
| Operating System | Android (ARM Cortex-A7, RK3288 quad-core, 1.88 GHz) |
| Power Supply | AC/DC dual-mode, built-in 6 Ah Li-ion battery |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Data Storage Capacity | >200,000 records |
| Connectivity | Wi-Fi, RJ45 Ethernet, USB port, optional external A4 printer |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-GCB12 |
| Price | USD 38,500 (FOB Qingdao) |
| Detection Principle | Rod TLC-FID (Thin-Layer Chromatography coupled with Flame Ionization Detection) |
| Standards Compliance | SY/T 6338–1997, SH/T 0753–2005, SY/T 5119–2016, SN/T 3118–2012, Q/SH3210 0065–2012, NB/SH/T 0509–2010 |
| FID Stability Time | <60 s |
| Detection Limit | <1 × 10⁻¹¹ g/s |
| Linear Dynamic Range | 10⁷ |
| Linearity | ±0.1% |
| Signal Output Range | 0–1000 mV (4 gain settings: 10⁻⁸ to 10⁻¹¹ V·s) |
| Scan Speed | 50–520 mm/min (user-defined) |
| fixed modes | 30 s/rod, 40 s/rod |
| Activation Time Options | 30 s / 45 s / 60 s |
| Sample Loading Capacity | 0.1–40 µg per rod |
| Rod Specifications | Two interchangeable formats — Ø0.9 mm × 153 mm (coating length 130 mm) and Ø1.0 mm × 163 mm (coating length 140 mm) |
| reusability | 80–100 cycles |
| Max. Rod Load | 1–10 rods per run |
| Humidity Control | 30–60% RH (auto-regulated year-round) |
| Temperature Control (Development Chamber) | 10–40 °C (active cooling/heating) |
| Data Acquisition Rate | 10 / 25 / 50 Hz |
| I/O Interface | Dedicated robotic arm I/O port for integration into automated lab environments |
| Communication | RS-232 & USB |
| Software Features | Automatic peak recognition (tailing, front/back shoulders, serrated, solvent), baseline tracking, adaptive peak width/slope adjustment, manual integration, post-run reprocessing, multi-method quantitation (area normalization, corrected normalization, internal/external standard, group-based, exponential), Excel/Word report export |
| Accessories | Integrated air generator (0–2 L/min, 0–0.4 MPa), H₂ generator (0–310 mL/min, 0.02–0.4 MPa), motorized development station with UV lamp (365 nm), 8-inch color touchscreen |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | YT-GZT |
| Price Range | USD 350 – 1,250 |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YT-JC12 / YT-JYC12T |
| Instrument Type | Benchtop Integrated Spectrophotometric Analyzer for Alcoholic Beverages |
| Application | Laboratory-based Food Safety Testing |
| Measurement Time | ≤3 min per sample |
| Ethanol Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L×W×H) | 43 × 35 × 20 cm |
| Weight | 5.1 kg |
| Core Technology | Integrated Benchtop Spectrophotometry with Multi-Wavelength Optical Engine |
| Sample Throughput | Configurable per assay protocol (1–12 simultaneous channels) |
| Detection Principle | Absorbance-based Quantitative Analysis via Fixed-Wavelength Photometry (410 / 520 / 590 / 630 nm), Expandable to 64 Wavelengths via Patented Optical Path Switching |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | YT-JD04 |
| Price | USD 4,200 (FOB Qingdao) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YT-JG1A / YT-JG2B |
| Price Range | USD 350 – 470 |
| Max Load | 500 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Penetration Needle Diameter | 1 mm |
| Adjustable Span for Bending Test | Up to 300 mm |
| Bending Probe Diameter | 50 mm (customizable) |
| Power Supply | 220 V AC adapter + Rechargeable Li-ion battery |
| Battery Runtime | 4–6 hours |
| Temperature Drift | 0.2 µV/°C (0–60°C) |
| Zero Drift | ≤0.1% FS / 8 h |
| Overload Capacity | 150% FS |
| Operating Temperature | 0–60°C |
| Operating Humidity | ≤80% RH |
| Auto-off Timer | 10–90 min |
| Data Storage | 999 test records |
| Display | Backlit LCD with digit inversion function |
| Unit Conversion | N, kgf, lbf (auto-switching) |
| Interface | USB for PC connectivity and data export |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-JNY |
| Price | USD 3,650 (approx.) |
| Measurement Range | 20–88 (arbitrary hardness units, calibrated per USP <1049> and Ph. Eur. 2.9.40 compliant soft capsule indentation scale) |
| Load Capacity Options | 50 N, 100 N, 500 N, or 1000 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Probe | Cylindrical, Ø10 mm or 10 mm² contact area |
| Upper Platen Parallelism | <0.025 mm |
| Lower Platen Diameter | 120 mm |
| Dimensions (W×D×H) | ~450 × 450 × 650 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YT-JSD2 |
| Max Load | 100 kg (also displayable in N and lb) |
| Resolution | 0.01 kg |
| Accuracy | ±1% FS |
| Measurement Depth | 0–450 mm |
| Power Supply | Rechargeable Ni-MH battery pack |
| Battery Runtime | 6–8 hours continuous operation |
| Temperature Drift | 0.2 µV/°C (0–60 °C) |
| Zero Drift | ≤0.1 %FS / 8 h |
| Calibration Range | Full-scale calibration |
| Operating Temperature | 0–60 °C |
| Operating Humidity | ≤80 % RH (non-condensing) |
| Overload Capacity | 150 % FS |
| Data Storage | 447 values |
| Auto-Power-Off | Adjustable from 10 to 90 minutes |
| Gravity Compensation | User-configurable local g-value |
| Peak Hold & Auto-Peak Modes | Yes |
| USB Data Export | Yes |
| Backlit LCD Display with Invert Function | Yes |
| Battery Level Indicator | 3-level icon |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Models | YT-KD1, YT-ZG02 |
| Price Range | USD 350 – 920 |
| Max Load | YT-KD1: 50 N |
| YT-ZG02 | 500 N |
| Resolution | YT-KD1: 0.01 N |
| YT-ZG02 | 0.1 N |
| Stem Diameter Measurement Range | 0–40 mm |
| Accuracy | ±0.5% FS |
| Units | N, kPa |
| Operating Temperature | −10 °C to +60 °C |
| Dimensions | 295 mm × 130 mm × 36 mm |
| Net Weight | ~600 g |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YT-KZ01-4 |
| Price | USD 3,950 (FOB Qingdao) |
| Operating System | Android 5.1.1+ |
| Tablet Display | 7-inch IPS LCD (1200×1920, 16:10) |
| Rear Camera | 13 MP autofocus, fixed-focus macro mode |
| Backlight Unit | High-luminance LED array with nano-patterned light guide plate and reflective backing |
| Illumination Uniformity | ±3% irradiance variation across 260×205 mm imaging area |
| Transparent Tray Dimensions | 260×205×15 mm (L×W×H) w/ alignment stopper |
| System Enclosure | Acrylic housing (chemical-resistant, non-yellowing grade) |
| Device Weight | 2.2 kg |
| Power Input | DC 5–12 V (rated 5 V / 5 A for backlight |
| Connectivity | Wi-Fi 802.11 b/g/n, USB 2.0 host/device, microSD slot (up to 128 GB) |
| Seed Counting Range | 50–1500 seeds per frame |
| Counting Accuracy | ±0.1% for round seeds (n ≥ 1000), ±5% for elongated seeds (n ≥ 1000) |
| Morphometric Accuracy | Mean area, perimeter, length, width, and aspect ratio error ≤5% (vs. caliper & image metrology reference standards) |
| Data Export | .xlsx (Excel 2007+ format), CSV, PNG report thumbnails |
| Cloud Integration | Yuntang Instrument Cloud Platform (HTTPS/TLS 1.2, OAuth 2.0 auth, audit-trail enabled) |