| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CGT-3100 |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | PCS-F |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SMART-01F |
| Pricing | Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ST-1/LAS |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TCO-270 |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TCO-L6 |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-108 |
| Pricing | Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-DGY-100 |
| Pricing | Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Model | ZYD-F |
| Function Type | Multi-analyte (Pesticide Residues, Veterinary Drug Residues e.g., Clenbuterol, Food Additives e.g., Nitrite, Heavy Metals via Optional Modules) |
| Sample Compatibility | Liquid, Extracted Homogenates, and Immunoassay Strips |
| Detection Limit | 0.01 mg/kg (for representative analytes e.g., organophosphates, nitrite) |
| Optical System | LED-based Photometric Detection at 410 nm, 520 nm, 590 nm, and 630 nm |
| Detection Time per Parameter | 3–10 min |
| Detection Channels | 12 Independent Optical Channels |
| Repeatability | ≤ ±3% CV |
| Display | ≥7-inch Color TFT Touchscreen |
| Detection Principles | Absorbance-based Spectrophotometry (for colorimetric assays) and Lateral Flow Immunoassay (LFIA) Interpretation |
| Microcontroller | High-Performance Embedded ARM Processor |
| Communication Interfaces | USB 2.0, Bluetooth 4.2, RS-232, Ethernet (Optional Wi-Fi Module) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Storage | Onboard Flash Memory (≥10,000 test records), Cloud Synchronization (via HTTPS API) |
| Dimensions | 380 mm × 280 mm × 150 mm |
| Net Weight | 3.5–4.8 kg |
| Light Source | Stable Cold LED Array |
| Environmental Operating Range | 10–35 °C, RH ≤80% (non-condensing) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-FA |
| Price | Upon Request |
| Potential Range | −1000 to +1000 mV |
| Reference Electrode Input Impedance | ≥1 × 10¹² Ω |
| Detection Sensitivity | ≤0.01 µg/kg |
| Input Bias Current | Available upon manufacturer consultation |
| Potential Increment | Available upon manufacturer consultation |
| Scan Rate | Available upon manufacturer consultation |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-HF |
| Instrument Type | Portable |
| Detection Principle | Photometric Method (Colorimetric Absorption) |
| Detectable Metals/Analytes | Dual- and Multi-parameter (Fe, As, Mn, Cd, Cr(VI), Pb, etc.) |
| Detection Time | ≤15 min per parameter |
| Accuracy | Relative Error ≤ ±10% |
| Precision | Relative Standard Deviation (RSD) ≤ 5% |
| Resolution | 0.01 mg/L |
| Power Supply | AAA Batteries |
| Interface | USB |
| Brand | Zhiyunda |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-NB |
| Detection Method | Rapid Test Strip (Paper Disk) Method |
| Measurement Range | 0–100% inhibition |
| Number of Detection Channels | 10 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.03 mg/kg (for common organophosphates and carbamates) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-NP(12A) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 12 independent detection channels |
| Measurement Accuracy | ≤ ±10% |
| Limit of Detection (LOD) | 0.1–5 mg/kg |
| Display | 8-inch capacitive touchscreen LCD |
| Connectivity | USB, Wi-Fi (802.11 b/g/n), RJ45 Ethernet |
| Operating System | Android-based embedded OS |
| Compliance | Designed per GB/T 5009.199–2003 for rapid screening of organophosphorus and carbamate pesticides in food matrices |
| Brand | Zhiyunda |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-NP6D |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 6 |
| Measurement Error | ≤5% |
| Limit of Detection | 0.01 mg/kg (varies by pesticide class) |
| Brand | Zhiyunda |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-NP96 |
| Detection Method | Enzyme Inhibition Rate Assay |
| Measurement Range | 0–3.5 Absorbance Units (A) |
| Number of Channels | 96 |
| Measurement Accuracy | ±1% (0–2 A), Linearity Error: ±0.1% (0–2 A) |
| Limit of Detection (LOD) | 0.2–3.0 mg/L |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-S1 |
| Pricing | Available Upon Request |
| Detection Principle | Isothermal Nucleic Acid Amplification with Real-Time Fluorescence Monitoring |
| Temperature Control Accuracy | ±0.5 °C |
| Fluorescence Excitation/Emission | Dual-Channel (FAM/HEX or equivalent) |
| Sample Throughput | 1–14 samples per run, up to 5 targets simultaneously |
| Detection Time | As low as 20 min for preliminary positive call |
| Data Storage | On-device SD card + cloud synchronization (AES-256 encrypted) |
| Compliance | Designed in alignment with ISO/IEC 17025 laboratory competence requirements and GB/T 27403–2019 (China National Standard for Molecular Testing in Food Safety Laboratories) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-SC96(B) |
| Pricing | Available Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-ZH |
| Function Type | Multi-analyte (Pesticide Residues, Veterinary Drug Residues, Heavy Metals, Microorganisms, Food Additives) |
| Sample Compatibility | Universal for Solid, Liquid, and Semi-solid Food Matrices |
| Detection Range | Pesticide residues (e.g., organophosphates, carbamates), veterinary drugs (e.g., chloramphenicol, sulfonamides), heavy metals (Pb, Cd, As, Hg via anodic stripping voltammetry), pathogenic microorganisms (via immunochromatographic lateral flow), food adulterants & illegal additives |
| LOD | 0.01 mg/kg for representative pesticide analytes |
| Optical System | LED cold light source |
| wavelength range | 380–800 nm |
| Detection Time | 3–10 min per assay |
| Detection Channels | 6 independent photometric channels (simultaneous multi-target quantification) |
| Repeatability | ≤ ±1% CV |
| Display | ≥7-inch capacitive touchscreen LCD |
| Detection Technologies | Integrated spectrophotometry, immunochromatography (lateral flow), thin-layer chromatography (TLC) imaging (254 nm UV excitation), fluorescence sensing, and anodic stripping voltammetry (ASV) |
| Connectivity | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, microSD slot |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Storage | Internal flash memory (≥100,000 records) + cloud synchronization (HTTPS-secured API endpoint) |
| Dimensions | 300 × 200 × 150 mm (L×W×H) |
| Net Weight | 2.3–2.8 kg |
| Enclosure Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Processor | Quad-core ARM Cortex-A53 or higher |
| Image Acquisition | CMOS-based direct optical signal capture (no post-processing interpolation) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Model | ZYD-ZH/02 |
| Function Type | Multi-analyte (pesticide residues, veterinary drug residues, food additives, heavy metals, mycotoxins, pathogenic microorganisms) |
| Sample Compatibility | Liquid, solid, and semi-solid food matrices (e.g., vegetables, fruits, meat, dairy, aquatic products, grains) |
| Detection Methods | Spectrophotometry (visible/NIR), immunochromatographic assay (colloidal gold lateral flow), ATP bioluminescence |
| Detection Time | 3–15 min per assay (pesticide screening) |
| Detection Channels | ≥8 independent optical channels with simultaneous dual-wavelength measurement capability |
| Repeatability | ≤±3% CV |
| Display | 15-inch capacitive touchscreen LCD (1920×1080) |
| Operating System | Android 9.0 (customized industrial firmware) |
| Data Storage | Internal 32 GB eMMC + microSD/TF slot (up to 256 GB) |
| Connectivity | Gigabit Ethernet, Wi-Fi 5 (802.11ac), Bluetooth 5.0, 4G LTE (optional module) |
| Power Supply | AC 220 V ±10%, 50 Hz / DC 12.6 V (rechargeable Li-ion battery, ≥4 h continuous operation) |
| Dimensions (L×W×H) | 380 × 320 × 180 mm |
| Net Weight | 7.2 kg |
| Light Source | Stable cold LED array with wavelength-specific emission profiles (450–650 nm, configurable per assay) |
| Processor | Quad-core ARM Cortex-A72 @ 1.8 GHz + dedicated DSP co-processor for real-time spectral deconvolution and signal normalization |
| Regulatory Alignment | Designed to support compliance with GB/T 5009.x, GB 2763, GB 31650, NY/T 761, SN/T 1944, and ISO/IEC 17025 documentation requirements |