- All
- Favorite
- Popular
- Most rated
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | compact |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Application Scope | Universal LC-MS/MS Platform |
| Key Specifications | 50 GBit/sec acquisition rate |
| Resolution | Ultra-High Resolution TOF (UHR-TOF) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | timsTOF Pro 2 |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Domain | Specialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery) |
| Regulatory Context | Compliant with GLP/GMP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Dual-Source GC-MS (EI + CI) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with Helical Resonant Plasma (HRP) source |
| Resolution | >40,000 FWHM (m/z 200) |
| Mass Accuracy | <1 ppm RMS (calibrated) |
| Scan Rate | Up to 50 spectra/sec (full-spectrum, high-res) |
| CI Reagent Gases | N₂H⁺, H₃O⁺, H(H₂O)ₙ⁺, NH₄⁺ (software-switchable, no hardware intervention) |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | EVOQ® DART-TQ+ |
| Application Scope | General-purpose small-molecule screening and quantitation |
| Ionization Modes | Fully integrated DART (Direct Analysis in Real Time), swappable with VIP-HESI (Heated Electrospray Ionization) and APCI sources |
| MRM Transition Rate | Up to 1,000 transitions/sec |
| Scan Speed | Up to 30,000 Da/sec |
| Detector | EDR™ Electron Multiplier with real-time gain optimization |
| Software Platform | tqControl™ with MRM Builder, automated tuning, daily performance verification, and rule-based data review |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF) |
| Model | timsTOF SCP |
| Application Domain | Specialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics |
| Ion Source | Optimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary |
| Vacuum Architecture | 8-stage Differential Vacuum System |
| Acquisition Mode | dia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation) |
| CCS Capability | Yes, Collision Cross Section–enabled Ion Mobility Separation |
| Scan Speed | >120 Hz MS/MS |
| Software Platform | timsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio |
| Data Format | Open .d Format (Bruker) |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsTOF HT |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Technology | Parallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Configuration | LC-MS/MS |
| Application Scope | Universal Quantitative Analysis |
| Regulatory Compliance | Designed for GLP/GMP environments, compatible with 21 CFR Part 11 audit trail requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole-TOF |
| Application Scope | Universal LC-MS/MS |
| Optional Features | ETD, HighMass Mode |
| Resolution (FSR) | >80,000 at full sensitivity |
| Mass Accuracy | <1 ppm RMS (calibrated, typical) |
| Mass Range | Up to 20,000 m/z (HighMass mode) |
| Isotopic Pattern Fidelity | True Isotopic Pattern (TIP) enabled |
| Software Platform | Compass DataAnalysis, Compass AutoPrep, SmartFormula™, SmartFormula 3D™ |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant workflows available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometry) |
| Model | scimaX™ |
| Resolution | R > 20,000,000 (at m/z 400) |
| Cooling System | Helium-gas-cooled Maxwell™ superconducting magnet (cryogen-free) |
| Ion Sources | Dual ESI/MALDI with automated switching |
| Fragmentation Modes | ECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD |
| Acquisition Mode | CASI (Collision-Activated Selective Ion accumulation) |
| Application Scope | Universal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsUltra AIP |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Specialized Proteomics & Multi-Omics Platforms |
| Software Integration | TIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS) |
| Ionization Modes | Dual MALDI/ESI |
| Application Focus | Label-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery |
| Software Platform | MALDI PharmaPulse® 2023 |
| Compliance Ready | GLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration) |
| Throughput | Up to 3 samples/sec on 1536-well plates |
| CCS Calibration | Yes, with internal standards |
| MALDI Source | 10 kHz smartbeam™ 3D laser, MALDI-2 option available |
| Sample Handling | Robotic MALDI target auto-loader, disposable targets (96–1536-well compatible) |
| Data Export | Native support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms |
Show next