| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ELEXSYS II |
| Pricing | Upon Request |
| Instrument Type | Continuous-Wave (CW) |
| Frequency Range Capability | 1 GHz to 263 GHz (CW and/or FT modes) |
| Optional Modules | DICE-II ENDOR, EPR Imaging, Pulsed FT-EPR, Multi-Frequency Resonators |
| Software Architecture | Open, Network-Enabled Client/Server Platform |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Continuous-Wave (CW) EPR |
| Magnet System | Permanent Magnet |
| Cooling | Air-Cooled (No Water Required) |
| Form Factor | Benchtop |
| Automation Level | Fully Automated Tuning, Data Acquisition & Analysis |
| Application-Specific Configurations | e-scan A (Radiation Dosimetry), e-scan B (Beer Freshness QC), e-scan F (Food Irradiation Verification), e-scan M (Stable Radical & Spin Adduct Detection, e.g., ROS/RNS) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | EMXplus, EMXmicro |
| Instrument Type | Continuous-Wave (CW) EPR |
| Configuration | Benchtop, Integrated Digital Architecture |
| Control Interface | Ethernet-connected, WinEPR Software Platform |
| Magnetic Field Resolution | 18-bit digital |
| Signal Digitization | 18-bit ADC |
| Microwave Bridge | Next-generation EMXplusX™ |
| Detection Modes | Simultaneous dual-phase (0° & 90° modulation), 1st- and 2nd-harmonic detection |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | A300/A200 |
| Instrument Type | Continuous-Wave (CW) EPR |
| Design Architecture | A300 – Modular Benchtop System |
| Regulatory Compliance | Designed for GLP/GMP-aligned laboratories |
| Software Framework | Bruker Xenon™ EPR Software Suite |
| Hardware Interface | Digital Signal Processing (DSP) Architecture with Real-Time Data Acquisition |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ESR5000 |
| Instrument Type | Continuous-Wave (CW) ESR |
| Sensitivity | 50 pM spin detection limit (aqueous standard, DPPH) |
| Operating Frequency | X-band (~9.5 GHz) |
| Magnet System | Permanent magnet with temperature-stabilized gap |
| RF Bridge | Dielectric resonator-based |
| Software Platform | Windows-based ESR Studio v4.x |
| Optional Accessories | Liquid nitrogen variable-temperature unit (93–473 K), optical access window for in situ photolysis, motorized sample rotator, autosampler, flow cell, tissue cell |