Calorimeter
Filter
Showing all 24 results
| Brand | ASTR/ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM3300 |
| Price | USD 3,500 (FOB Shanghai) |
| Measurement Range | 1,000–40,000 kJ/kg |
| Accuracy | Relative Standard Deviation ≤0.2% |
| Temperature Resolution | 0.0001 K |
| Test Duration | ~15 min per sample |
| Power Consumption | ≤60 W |
| Dimensions | 650 mm × 390 mm × 450 mm |
| Operating Ambient | 10–35 °C, RH ≤80%, 220 V ±10% AC |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XRY-1C |
| Measurement Mode | Isoperibol (Constant-Temperature Jacket) |
| Instrument Type | Oxygen Bomb Calorimeter |
| Intelligence Level | Fully Automated with PC Control |
| Temperature Range | 5°C to 35°C |
| Temperature Detection Threshold | 0.001°C – 0.01°C |
| Temperature Resolution | 0.0001°C |
| Temperature Stability | ≤0.001°C per 30 min |
| Temperature Tracking Rate | ~0.01°C/s – 0.05°C/s |
| Single-Sample Test Duration | ~8 min (Standard Mode), ~3 min (Rapid Mode) |
| Bomb Pressure Rating | 20 MPa |
| Pressure Resolution | 0.001 MPa |
| Brand | FoShan TST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARC Series |
| Pricing | Available Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | ZNLRY-2005 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibolic (Constant-Temperature Jacket) |
| Temperature Range | 0 °C to 65 °C |
| Temperature Resolution | 0.0001 °C |
| Temperature Precision | ±0.003 °C |
| Single-Sample Test Duration | 18 min |
| Heat Capacity (Water Equivalent) | ~10,500 J/K |
| Inner Bucket Volume | 2000 mL |
| Outer Jacket Volume | ~20 L |
| Sample Mass Range | 0.5–1.5 g |
| Power Supply | AC 220 V, 50 Hz |
| Repeatability of Heat Capacity Calibration | <0.1% RSD |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | ARC 244 |
| Temperature Range | RT to 500 °C |
| Temperature Tracking Rate | 0–20 °C/min |
| Minimum Detectable Heat Flow Rate | 0.01 °C/min |
| Pressure Range | 0–200 bar |
| Optional Features | Integrated Stirring, Venting Module, VARIPHI™ Thermal Inertia Compensation Technology |
| Safety Architecture | Dual-Redundant Interlock System, Top-Lifting Furnace Assembly, Tubular Heater Design for Minimized Thermal Backflow |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | ARC254 |
| Temperature Range | RT to 500°C |
| Temperature Tracking Rate | 0–200°C/min |
| Minimum Detectable Heat Flow Rate | 0.01°C/min |
| Pressure Range | 0–200 bar |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Optional Accessories | VARIPHI™ Technology Module, Stirring/Injection/Emission Units, Battery Test Fixture, Nail Penetration Fixture for Li-ion Cells |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | MMC274 Nexus |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | RT to 500°C |
| Temperature Resolution | 0.01°C |
| Pressure Range | 0–100 bar |
| Heating Rate | 0–2°C/min |
| Tracking Rate | 0–50°C/min (standard) or 0–250°C/min (high-speed module) |
| Temperature Control Accuracy | ±0.01°C |
| Pressure Accuracy | ±0.01 bar |
| Sample Volume | 0.1–2.5 mL |
| Heat Flow Sensitivity | 25–250 µW/g (mode-dependent) |
| Scan Sensitivity | 0.002°C/min |
| Sample Types | Solids, Liquids, Powders |
| Optional | Custom sample vessels, button-cell test fixture, VariPhi™ thermal compensation technology |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6200 |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Bomb Pressure Rating | 200 atm |
| Bomb Volume | 342 mL |
| Data Storage Capacity | 1000 tests |
| Interface Options | RS-232, USB, Ethernet, Balance Integration, Printer Port |
| Operating System | Linux-based embedded controller |
| Calibration & Reporting | Automatic correction for fuse wire, nitric acid formation, sulfur oxidation, and hydrogen combustion enthalpy |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6400 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J/K |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Filling | Fully Automated |
| Jacket Water Filling | Fully Automated |
| Pressure Release | Automated |
| Bomb Rinsing | Automated |
| Data Storage Capacity | 1,000 tests |
| Connectivity | Ethernet |
| Display | Touchscreen LCD |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DMC-196 |
| Measurement Mode | Isothermal Microcalorimetry |
| Instrument Type | Calvet-type Heat Flow Calorimeter |
| Key Features | Ultra-low temperature capability, high-sensitivity 3D thermopile sensor, dual-mode (DSC & IMC), high-pressure compatibility up to 350 bar |
| Temperature Range | −196 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.1 µW (heat flow) |
| Temperature Scan Rate | 0.001–1 °C/min |
| Single-sample Test Duration | ~15 min |
| Calorimetric Cell Max Pressure Rating | 350 bar |
| Heat Capacity (typical) | ~10,500 J/K |
| Pressure Resolution | 0.1 µW (equivalent heat flow resolution under pressure coupling) |
| Outer Dewar Volume | Up to 12.5 mL |
| Inner Sample Cell Volume | Up to 12.5 mL |
| Peak-to-Peak Noise Level | 1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.2% |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Calvet-type Microcalorimeter |
| Measurement Modes | Isothermal Microcalorimetry (IMC) & Differential Scanning Calorimetry (DSC) |
| Sample Capacity | Up to 12.5 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy & Precision | ±0.1 °C |
| Temperature Scan Rate | 0.001–2 °C/min |
| Heat Flow Resolution | 0.1 μW |
| Baseline Noise (Peak-to-Peak) | ≤1 μW |
| Calorimetric Accuracy | ±0.2% |
| Calorimetric Precision | ±0.2% |
| Maximum Pressure Rating (High-Pressure Cell) | 100 MPa (1,000 bar) |
| Pressure Resolution | 350 bar (for integrated pressure tracking cells) |
| External Bath Volume | Up to 12.5 mL |
| Internal Bath Volume | 12.5 mL |
| Dimensions | 29 cm × 29 cm × 63 cm |
| Weight | 25 kg |
| Power Supply | 110–240 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Isothermal Microcalorimeter |
| Instrument Category | Cone Calorimeter (Note: *This is a misclassification in source data |
| Model | MIC-90 |
| Measurement Mode | Isothermal |
| Temperature Range | 3 °C to 95 °C |
| Temperature Stability | ±0.001 °C |
| Temperature Precision | ±0.15 °C |
| Single-Sample Measurement Time | ~15 min |
| Heat Capacity (System) | ~10,500 J/K |
| Outer Bath Volume | 25 mL |
| Inner Bath Volume | 25 mL |
| Channel Configurations | 3-channel or 8-channel swappable modules |
| Detection Limit | 2 μW (8-ch), 8 μW (3-ch) |
| Short-Term Noise | <1 μW (8-ch), <8 μW (3-ch) |
| Baseline Drift (24 h) | <5 μW (8-ch), <55 μW (3-ch) |
| Measurement Range | ±900 mW |
| Sample Cell Volume Options | 25 mL or 100 mL |
| Cell Materials | Borosilicate glass, stainless steel, or custom polymer |
| In-situ Mixing | Motorized stirrer with adjustable speed |
| Thermal Sensing Principle | Differential Seebeck-effect planar thermopile sensors |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Reaction Calorimeter |
| Automation Level | Fully Automated |
| Temperature Range (Reactor) | –25 °C to 200 °C |
| Temperature Range (Oil Bath) | –45 °C to 250 °C |
| Temperature Resolution | 1.0 mK |
| Temperature Control Precision | ±0.1 K |
| Calorimetric Methods | Heat-Flow, Power Compensation (optional), Reflux (optional) |
| Reactor Volume | 1000 mL (customizable) |
| Maximum Operating Pressure | 10 MPa |
| Stirring Speed | up to 2000 rpm |
| Torque | up to 75 N·cm |
| Oil Circulation Rate | 35–76 L/min |
| Calibration Heater | 0–50 VDC / 3.00 A / 120 W |
| Power Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total System Power | 7000 W |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Weight | 210 kg |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet Pro |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calvet-type Heat-Flow Calorimetry |
| Sample Mass Range | mg-scale |
| Temperature Range | –120 °C to 830 °C |
| Pressure Capability | Up to 500 bar (with optional high-pressure module) |
| Vacuum Compatibility | Yes |
| Cp Accuracy | High-precision absolute heat capacity measurement |
| Operating Modes | Isothermal, Dynamic Scanning, and Stepwise Temperature Programs |
| Sensor Architecture | Symmetric 3D thermopile array surrounding the sample and reference positions |
| Calibration Method | Joule-effect electrical calibration |
| Sample Environment Control | Integrated pressure regulation, monitoring, and control |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SDAC1000 |
| Pricing | Upon Request |
| Intelligence Level | Fully Automated |
| Instrument Type | Isoperibol Oxygen Bomb Calorimeter |
| Temperature Measurement Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Heat Capacity Precision | ≤0.10% RSD |
| Heat Capacity Stability | ≤0.20% drift over 12 months |
| Single Test Duration (Fast Mode) | <11 min |
| Single Test Duration (Classical Mode) | <13 min |
| Max Power Consumption | 0.65 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (Main Unit) | 428 mm × 565 mm × 450 mm |
| Weight (Main Unit) | ~45 kg |
| Water Jacket Dimensions | 220 mm × 565 mm × 410 mm |
| Water Jacket Weight | ~25 kg |
| Compliance | GB/T 213-2008, GB/T 384-1981, GB/T 30727-2014, ASTM D5865-2007, JC/T 1005-2006, ISO 1928-2020 |