Cell Analysis
Filter
Showing 91–120 of 367 results
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | MoFlo XDP |
| Product Category | High-Performance Flow Cytometry-Based Cell Sorting System |
| Sample Size Range | 0.5–50 µm |
| Maximum Analysis Rate | >100,000 cells/sec |
| Maximum Sorting Rate | >70,000 cells/sec |
| Fluorescence Parameters | Up to 18 colors + 2 scatter channels (with multi-laser configuration) |
| Sorting Output | 4-way simultaneous sorting |
| Nozzle Options | 8 interchangeable nozzles (50–200 µm) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Beckman Coulter |
|---|---|
| Model | Vi-CELL XR |
| Origin | USA |
| Product Type | Automated Cell Viability and Counting System |
| Sample Volume Range | 0.5–100 µL |
| Cell Size Detection Range | 2–700 µm |
| Imaging Sensor | 1394 × 1040 CCD array |
| Interface | IEEE 1394 (FireWire) |
| Focus Mechanism | Motorized Auto-Focus |
| Reagent Kits Available | Vi-CELL XR Quad Pack, Vi-CELL AS/S Quad Pack |
| Calibration Standards | Vi-CELL Concentration Control, Vi-CELL Focus Control |
| Data Export Format | Native Excel (.xlsx), CSV, TIFF image archives |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S3e |
| Product Type | Flow Cytometric Cell Sorter |
| Lasers | 3 lasers (405 nm, 488 nm, 640 nm) |
| Fluorescence Detection Channels | 6 parameters (4 fluorescence + FSC + SSC) |
| Coefficient of Variation (CV) | ≤2.5% for FITC beads |
| Sorting Speed | Up to 100,000 events/sec |
| Sensitivity | ≥125 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Sample Temperature Control | 4–35 °C adjustable, ±0.5 °C stability |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm |
| Auto-Calibration | Fully automated hydrodynamic and optical alignment via AutoGimbal™ system |
| Biosafety Compatibility | Certified for operation inside Class I biosafety cabinets |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | TC20 |
| Measurement Time | 30 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 2 samples per run |
| Detectable Cell Diameter | 6–50 µm |
| Data Storage | Internal memory for 100 assays |
| Dimensions (W × D × H) | 19 × 15 × 25.4 cm |
| Weight | 2.2 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZE5 |
| Product Type | Flow Cytometer |
| Application | Research |
| Lasers | 5 lasers |
| Detection Parameters | 30 parameters |
| Coefficient of Variation (CV) | ≤3% |
| Sample Flow Rate | 3.5 µL/min |
| Fluorescence Sensitivity | ≤10 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Event Acquisition Rate | Up to 100,000 events/sec |
| Maximum Data Storage per Acquisition | 100 million events |
| Throughput | 96-well plate in ≤12 minutes |
| Fluidic Velocity | 8 m/sec |
| Software | Everest Flow Cytometry Software |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ZOE |
| Product Category | Integrated Fluorescent Cell Imaging System |
| Excitation/Emission Filters (Blue Channel) | 355/40 nm / 433/36 nm |
| Excitation/Emission Filters (Green Channel) | 480/17 nm / 517/23 nm |
| Excitation/Emission Filters (Red Channel) | 556/20 nm / 615/61 nm |
| Imaging Sensor | 5 MP, 12-bit CMOS monochrome camera |
| Display | 10.1-inch high-resolution LCD touchscreen (1280 × 768) |
| Objective | 20× achromatic, wide-field mounting (0.70 mm² FOV, ~180% larger than standard 20×) |
| Stage | Motorized XY stage with ±6 mm travel, touch-controlled navigation |
| Illumination | LED-based brightfield (adjustable green LED ring with quadrant masking for oblique illumination) and fluorescence excitation (no warm-up, >10,000 h lifetime) |
| Image Storage | 16 GB internal memory (~2,500 JPEG images) |
| Output Formats | JPEG, TIFF, RAW |
| Software Features | Real-time gain, exposure time, LED intensity, and contrast adjustment |
| Brand | Bio-Techne |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Pala Single Cell Dispenser |
| Type | Fully Automated |
| Sorting Speed | 50,000 cells/s |
| Maximum Cell Concentration | 150,000,000 cells/mL |
| Fluorescence Detection Channels | 11 |
| Operating Pressure | <2 psi |
| Compatible Plate Formats | 96-well and 384-well microplates |
| Laser Configurations | 488 nm + 405 nm or 488 nm + 561 nm |
| Brand | Bio-Techne |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Single Cell Dispenser |
| Price Range | USD 1–2 (Quotation upon Configuration & Service Package) |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | CLARIOstar ACU Ischemia-Reperfusion Research System |
| Application | High-throughput, real-time intracellular oxygen monitoring under physiologically relevant O₂/CO₂-controlled conditions |
| Regulatory Status | Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP-compliant workflows and FDA 21 CFR Part 11–ready software configurations (with optional audit trail and user access control) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agile Pulse In Vivo |
| Product Category | In Vivo Electroporation System |
| Voltage Range | 50–1000 V |
| Pulse Duration | 5 µs – 10 ms |
| Inter-Pulse Interval | 20 µs – 1 s |
| Data Export | USB Storage |
| Operating Temperature | 10–40 °C |
| Input Voltage | 100–250 VAC |
| Dimensions (L×W×H) | 32.0 × 20.0 × 39.9 cm |
| Weight | 11.34 kg |
| Electrode Compatibility | Multi-needle Matrix Electrodes (Subcutaneous & Intramuscular) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agile Pulse Max |
| Product Type | Cell Analysis System |
| User Interface | Color Touchscreen |
| Voltage Range | 50–1200 V |
| Pulse Duration | 5 µs – 10 ms |
| Inter-Pulse Interval | 20 µs – 1 s |
| Data Export | USB Flash Drive |
| Operating Temperature | 10–40 °C |
| Input Voltage | 100–250 VAC |
| Dimensions (L×W×H) | 32.0 × 20.0 × 39.9 cm |
| Weight | 11.34 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 399 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ECM 630 |
| Price Range | USD $13,500 – $40,500 (FOB US Port) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECM2001 |
| Price Range | USD 14,000 – 43,000 |
| Product Category | Cell Analysis System |
| AC Parameters | Non-sinusoidal waveform, 1 MHz frequency, 0–75 V amplitude, 0–99 s duration, AC/DC inter-pulse interval 50 µs |
| DC Parameters (High-Voltage Mode) | 10–3000 V (10 V step), pulse width 1–99 µs (1 µs step) |
| DC Parameters (Low-Voltage Mode) | 10–500 V (10 V step), pulse width 1–99 ms (1 ms step) or 10–990 µs (10 µs step) |
| Pulse Count | 1–9 pulses per train |
| Inter-Pulse Interval | 1 s |
| Cycle Count | 0–9 cycles |
| Minimum Load Impedance | 20 Ω |
| Electrode Compatibility | All BTX electrodes except 35 mm dish electrodes |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IBTC-100S |
| Stretch Rate | 1–15% strain per cycle |
| Stretch Frequency | 0.2–5 Hz |
| Waveform | Sinusoidal |
| Static & Dynamic Stretch Modes | Yes |
| Custom Strain Profile Support | Yes |
| Microscopy-Compatible Substrate | Transparent bottom for live-cell imaging |
| Strain Uniformity Across Culture Area | ≥95% |
| Measurement Uncertainty | <1% (engineering strain output) |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | IBTC-10S |
| Quotation | Upon Request |
| Stretching Frequency Range | 0.2–5 Hz |
| Elongation Range | 1–15% |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Cellen One |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | cellenONE F1.1 |
| Product Type | Automated Single-Cell Dispensing System |
| Application Domain | Research |
| Laser Excitation Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution (Spatial) | 200 nm |
| Fluorescence Sensitivity Threshold | ≥10,000 cells/s |
| Cell Processing Throughput | 0.2 cells/s (single-cell validation rate) |
| Core Technology | Piezoelectric Acoustic Droplet Ejection (ADE) with Real-Time Optical Monitoring |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | cellenONE |
| Product Category | Flow Cytometry-Based Single-Cell Dispenser |
| Application Domain | Research |
| Laser Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution | 200 nm |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Dispensing Throughput | 0.2 wells/s |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F1.4 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | f1.4 |
| Detection Channels | 3 |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Analysis Speed | 0.2 mL/min |
| Detection Resolution | 200 µm |
| Laser Efficiency | 95% |
| Product Type | Flow Cytometry-Based Single-Cell Isolation Platform |
| Compatible Collection Formats | 96-well, 384-well, 1536-well, and custom microplates |
| Reagent Dispensing Precision | Nanoliter (nL)-level |
| Single-Cell Isolation Accuracy | ≥95% |
| Minimum Input Volume | 5 µL |
| Minimum Viable Cell Input | 50 cells |
| Cell Viability Post-Isolation | >90% (vs. typical FACS: 70–85%) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X1 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X1 |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | cellenONE X1 |
| Pricing | Available Upon Request |
| Brand | Chengmeng |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | EVOM4 |
| Impedance Range | 0–105,000 Ω (auto-ranging across Low/Mid/High ranges) |
| Sampling Rate | 12.5 Hz |
| Sampling Averaging | 20 samples/sec |
| Current Output | 2 µA / 4 µA / 10 µA (auto/manual mode) |
| Impedance Resolution | 0.1 Ω (<200 Ω), 1 Ω (≥200 Ω) |
| Impedance Accuracy | ±0.1 Ω (<200 Ω) |
| Voltage Resolution & Accuracy | 0.1 mV |
| Display Update Interval | 0.5 s |
| Power | Rechargeable 3.7 V Li-ion battery (2500 mAh) |
| Charging Time | 5.5 h (off), 6 h (on) |
| Charging Current | 200 mA |
| Brand | Chuanyi Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Qi3531 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Sample Throughput | Up to 20 cell types per analysis session |
| Power Supply | Dual-mode (AC adapter + internal rechargeable battery) |
| Display | Integrated LCD screen with real-time classification summary |
| Brand | KELLER HCW |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SAMPLER1 |
| Pricing | Available Upon Request |
| Product Type | Flow Cytometer |
| Spectral Detection Range | 420–832 nm |
| Dynamic Range | 10⁷·² (log scale) |
| Fluorescence Sensitivity | High |
| Resolution | High |
| Linearity | ≥0.99 |
| Continuous Sample Loading Duration | Up to 30 min |
| Temperature Control | Precise |
| Vibration Damping | Integrated |
| Optical-Electronic Module | Modular Design |