| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | JY88-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 250 W (adjustable from 1% to 100%) |
| Sample Volume Capacity | 10–200 mL |
| Display | 7-inch Touchscreen Interface |
| Duty Cycle Range | 0.1–99.9% |
| Standard Probe | 6 mm titanium alloy (TC4) horn |
| Optional Probes | 2 mm, 3 mm, 10 mm |
| Safety Features | Overtemperature, overload, and timer alarms |
| Dimensions (Main Unit) | 430 × 245 × 300 mm |
| Weight (Unit + Transducer) | 8.5 kg |
| Optional Acoustic Enclosure Dimensions | 345 × 345 × 535 mm |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCIENTZ-650J |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9°C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 650 W (adjustable from 1% to 100% in 1% increments) |
| Sample Volume Capacity | 100 µL – 250 mL |
| Display | 7-inch capacitive touchscreen |
| Probe Options | Standard 6 mm tapered probe |
| optional probes | 2, 3, 8, 10, and 13 mm diameter |
| Probe Material | TC4 titanium alloy (aerospace-grade α+β titanium alloy) |
| Cooling Mode | External circulating chiller compatible / internal temperature monitoring with auto-shutdown |
| Safety Features | Overload protection, overtemperature cutoff (user-definable threshold), real-time thermal monitoring, timed operation with ±0.1 s resolution |
| Control Modes | Continuous and pulsed ultrasonication (pulse on/off ratio programmable) |
| Enclosure | Acoustically damped steel chassis with integrated sound-absorbing panels |
| Dimensions (W×D×H) | 312 × 334 × 510 mm |
| Weight | Approx. 28 kg |
| Internal Illumination | LED lighting for sample chamber visibility |
| Sanitization | UV-C lamp integrated into lid assembly (optional activation cycle) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-950E |
| Temperature Range | 0–99°C |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Ultrasonic Power Output | 5–950 W (adjustable) |
| Sample Volume Capacity | 100 µL – 600 mL (probe-dependent) |
| Brand | SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Model | UP-250 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 19–25 kHz |
| Ultrasonic Output Power | 250 W |
| Sample Volume Capacity | 0.5–10 mL |
| Display | 4.3-inch Touchscreen |
| Control Modes | Automatic & Manual (footswitch optional) |
| Pulse Duration | 0.1–99 s (on/off) |
| Total Sonication Time | 0.1–99 min |
| Horn Diameter | 3 mm |
| Dimensions (UP-250) | 270 × 245 × 116 mm |
| Power Supply | 220 V / 50 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX130PB (Hand-Triggered Pulse) & VCX130FSJ (Foot-Switch Pulse) |
| Output Power | 130 W |
| Frequency | 20 kHz |
| Dimensions (H×W×D) | 115 × 250 × 320 mm |
| Weight | 3.0 kg (VCX130PB), 3.2 kg (VCX130FSJ) |
| Transducer Models | CV188 (VCX130PB), CV18 (VCX130FSJ) |
| Transducer Specs | Ø32 mm × 146 mm, 340 g, cable length 1.5 m (VCX130PB), 1.8 m (VCX130FSJ) |
| Standard Probe | Ø3 mm titanium alloy (Ti-6Al-4V), 138 mm length, volume range 250 µL–10 mL, part #630-0422 |
| Input Power | 220 V, 50/60 Hz |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KBS-650 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz |
| Maximum Ultrasonic Power Output | 650 W |
| Adjustable Power Range | 0–100% |
| Sample Volume Capacity | 0.5–500 mL |
| Processing Volume per Cycle | Up to 600 mL |
| Probe Diameter Options | Φ2, Φ3, Φ8 (standard), Φ10, Φ12, Φ15 mm |
| Duty Cycle Adjustment | 1–999 s |
| Timer Range | 0–24 h |
| Transducer Material | TC4 Titanium Alloy |
| Safety Features | Overload Protection, Audible/Visual Alarm, LED Illuminated Touch Interface, Motorized Vertical Probe Positioning with Wireless Remote Control |
| Structural Design | Modular Stackable Assembly (Optional Integrated or Separated Generator–Transducer Configuration) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | GM-01 |
| Instrument Type | Bead Mill Cell Disruptor |
| Temperature Range | 0 °C to 40 °C |
| Sample Volume | 2.0 mL per tube |
| Throughput | Up to 12 samples (6 with metal beads) |
| Maximum Centrifugal Force | 1300 × g |
| Speed Range | 500–4500 rpm |
| Vortex Mixing Intensity | 10 levels (Level 10 ≈ 2600 rpm equivalent shear) |
| Timer Range | 0–50 sec, or 1 min–99 h 50 min |
| Dimensions | 210 × 268 × 176 mm (W × D × H) |
| Weight | ~3.5 kg |
| Power Supply | AC 100–125 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VP-050N / VP-300N |
| Output Power | 50 W (VP-050N), 300 W (VP-300N) |
| Frequency Range | 19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N) |
| Transducer Interface | Integrated horn-type piezoelectric converter with auto-tuning |
| Control | Digital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s) |
| Probe Options | Φ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N) |
| Dimensions (W×D×H) | 122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N) |
| Weight | 4.5 kg (VP-050N), 6.7 kg (VP-300N) |
| Power Supply | AC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-01 |
| Disruption Principle | Horizontal umbrella-shaped oscillation |
| Speed Range | 2,500–4,600 rpm (6 preset steps) |
| Sample Volume | 2 mL |
| Sample Capacity | 1 tube per run |
| Compatible Beads | Glass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars |
| Operating Temperature | +5 to +35 °C |
| Vibration Frequency | 40–78 Hz |
| Timer Range | 5–60 s (6 presets) |
| Safety Features | Lid interlock stop, overload current protection |
| Dimensions | 172 × 280 × 160 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-12 |
| Instrument Type | Bead Mill Cell Disruptor |
| Operating Frequency | 53 Hz |
| Sample Capacity | 12 × 5.0 mL tubes |
| Throughput | 12 samples per run |
| Speed Range | 1,800–3,200 rpm (8-step digital adjustment) |
| Timer | 1–300 s (1-s increment, memory for 2 speed/time presets) |
| Safety Features | Lid-interlock shutdown, overload current protection |
| Dimensions | 310 × 400 × 200 mm (W × D × H) |
| Weight | ~15 kg |
| Power Supply | AC 100 V, 4 A |
| Ambient Operating Range | +5 °C to +35 °C |
| Tube Compatibility | Standard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105) |
| Bead Compatibility | Stainless steel (SUS), zirconia, glass beads |
| Brand | TOMY |
|---|---|
| Origin | Japan |
| Model | MS-100 |
| Drive Type | Brushless Inverter Motor |
| Speed Range | 2000–5500 rpm (100 rpm increments) |
| Time Setting | 1–300 s (1–100 s above 5100 rpm) |
| Sample Capacity | 12 × 2.0 mL tubes |
| Motion Principle | Microprocessor-Controlled 3D Rotational High-Speed Motion (Patented) |
| Safety Features | Lid-Open Detection, Motor Overheat Protection, Abnormal Rotation Detection |
| Display | Backlit LCD |
| Dimensions | 280 W × 320 D × 305 H mm |
| Weight | ~17 kg |
| Power Supply | AC 120 V, 3 A, 50/60 Hz, 1P |
| Brand | SOCOREX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Miniature Set |
| Instrument Type | Manual Mechanical Cell Disruptor |
| Sterilization | Autoclavable (121°C, 20 min) |
| Material | Low-Extractable Borosilicate Glass (WHEATON 33) |
| Package Includes | 7 Units (1× Tenbroeck, 1× G.P.I. 0.5 mL, 1× Dounce 1 mL, 1× 0.1 mL, 1× 0.2 mL, 1× Potter-Elvehjem 2 mL, 1× Conical 1 mL) |
| Compliance | USP <661.1>, ISO 8536-1 |