Cell Disruptor
Filter
Showing 1–30 of 202 results
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | HPH-L2 |
| Maximum Pressure | 2000 bar |
| Maximum Feed Particle Size | 500 µm |
| Flow Rate | 5–15 L/h |
| Minimum Sample Volume | 15 mL |
| Noise Level | 65 dB |
| Power | 1.5 kW |
| Dimensions (L×W×H) | 545 × 755 × 494 mm |
| Weight | 140 kg |
| Material | SAF2507 duplex stainless steel |
| Homogenization Valve | High-efficiency safety valve with manual pressure adjustment |
| Control Interface | Touchscreen panel with real-time pressure display, data logging, export capability, and programmable safety cutoff |
| Compliance | Manufactured per EU Machinery Directive 98/37/EC (MD) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPH-L2 |
| Instrument Type | High-Pressure Cell Disruptor |
| Compliance | EU Machinery Directive 98/37/EC (MD) |
| Max Inlet Particle Size | 500 µm |
| Flow Rate | 5–15 L/h |
| Max Operating Pressure | 2000 bar |
| Minimum Sample Volume | 15 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 1.5 kW |
| Cleaning & Sterilization | Yes |
| Dimensions (W×D×H) | 545 × 755 × 494 mm |
| Weight | 140 kg |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HPH-L2 |
| Max. Pressure | 2000 bar |
| Max. Inlet Particle Size | 500 µm |
| Flow Rate | 5–15 L/h |
| Minimum Sample Volume | 15 mL |
| Noise Level | 65 dB(A) |
| Power | 1.5 kW |
| Dimensions (W×D×H) | 545 × 755 × 494 mm |
| Weight | 140 kg |
| Material | SAF2507 super duplex stainless steel |
| Compliance | EU Machinery Directive 98/37/EC (MD) |
| Cleaning & Sterilization | CIP-compatible, autoclavable components |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPH-L3 |
| Max. Inlet Particle Size | 500 µm |
| Flow Rate | 10–40 L/h |
| Max. Operating Pressure | 1800 bar |
| Minimum Sample Volume | 30 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 5.5 kW |
| Cleaning & Sterilization | Yes |
| Dimensions (L×W×H) | 658 × 868 × 920 mm |
| Weight | 280 kg |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPH-L3 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max. Inlet Particle Size | 500 µm |
| Flow Rate | 10–40 L/h |
| Max. Operating Pressure | 1800 bar |
| Minimum Sample Volume | 30 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 5.5 kW |
| Cleaning & Sterilization | Yes |
| Dimensions (W×D×H) | 658 × 868 × 920 mm |
| Weight | 280 kg |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPH-L3 |
| Max. Inlet Particle Size | 500 µm |
| Flow Rate | 10–40 L/h |
| Max. Operating Pressure | 1800 bar |
| Minimum Sample Volume | 30 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 5.5 kW |
| Dimensions (L×W×H) | 658 × 868 × 920 mm |
| Weight | 280 kg |
| Construction Material | SAF2507 Super Duplex Stainless Steel |
| Compliance | EU Machinery Directive 98/37/EC (MD) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPH-P Series |
| Instrument Type | High-Pressure Cell Disruptor |
| Flow Rate | 80–2000 L/h |
| Operating Pressure | 800–1500 bar |
| Construction Material | SAF2507 Super Duplex Stainless Steel |
| Control Interface | Touchscreen Panel with Real-Time Pressure Monitoring & Data Export Capability |
| Optional Systems | Variable-Frequency Flow Control, Automated Pressurization, PLC Integration, Temperature Control, Multi-Stage Homogenization, Closed-Loop Circulation, Sample Preconditioning Module |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | HPH-P1 |
| Construction | Modular pump head |
| Wetted materials | SAF2507 super duplex stainless steel |
| Homogenization valve | High-efficiency, safety-engineered |
| Pressure regulation | Manual handwheel + optional pneumatic actuation |
| Drive system | Stable, continuous-duty motor |
| Control interface | Touchscreen panel with real-time pressure monitoring, data logging, export capability (CSV), and programmable safety pressure limits |
| Optional modules | Variable-frequency flow control, automated pressurization, PLC-based automation, jacketed temperature control, multi-stage homogenization, closed-loop recirculation, and integrated sample preconditioning |
| Flow rate range | 80–2000 L/h |
| Maximum operating pressure | 1500 bar (standard configurations) |
| Application scope | Cell disruption (E. coli, yeast, mammalian cells), liposome & LNP formulation, fat emulsion processing, nanostructured material dispersion (CNTs, graphene, nanocellulose), sterile pharmaceutical final fill support |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | HPH-P1 |
| Construction | Split-head pump design |
| Wetted Materials | SAF2507 super duplex stainless steel |
| Homogenization Valve | High-efficiency safety valve with precision pressure control |
| Drive System | Stable high-torque motor assembly |
| Control Interface | Touchscreen panel with real-time pressure monitoring and data logging |
| Pressure Regulation | Manual and pneumatic dual-mode adjustment |
| Safety Features | Programmable pressure limit with audible/visual alarm |
| Optional Modules | Variable-frequency flow control, auto-pressurization system, PLC-based automation, jacketed temperature control, multi-stage homogenization, closed-loop recirculation, pre-conditioning unit |
| Flow Rate Range | 80–2000 L/h |
| Maximum Operating Pressure | 1500 bar (standard), 1000 bar (high-flow variants) |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AH-1500 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1500 bar (22,500 psi) |
| Optional Overpressure Capability | 1800 bar (27,000 psi) |
| Flow Rate | 15 L/h |
| Minimum Sample Volume | 25 mL |
| In-Line Cooling System | Integrated, maintains sample temperature < 20 °C |
| Contact Wetted Materials | ASTM A240 316L stainless steel |
| Motor Power | 2.2 kW, 380 V / 50 Hz |
| Weight | 110 kg |
| Compliance | CE-marked, GMP-compliant design |
| Particle Size Output | < 100 nm (after single-pass homogenization) |
| Disruption Efficiency | >95% for *E. coli*, >90% for yeast |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Model | AH-1500 |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure | 1500 bar (22,500 psi), up to 1800 bar (27,000 psi) |
| Motor Power | 2.2 kW, 380 V / 50 Hz |
| Throughput | 15 L/h |
| Minimum Sample Volume | 25 mL |
| In-Line Cooling System | Integrated, maintains sample temperature < 20 °C |
| Wetted Materials | 316L stainless steel |
| Compliance | CE-certified, GMP-compliant design |
| Particle Size Reduction | < 100 nm |
| Cell Disruption Efficiency | >95% for E. coli, >90% for yeast |
| Weight | 110 kg |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Manufacturer | ATS (Original Equipment Manufacturer) |
| Product Type | Imported |
| Model | H10 |
| Instrument Category | High-Shear Cell Disruptor |
| Motor | German-sourced, industrial-grade |
| Bearing | SKF |
| Power | 0.5 kW |
| Voltage | 220 V, 50 Hz |
| Speed Range | 10,000–28,000 rpm (7-step infinitely variable control) |
| Tip Linear Velocity | up to 28.5 m/s |
| Net Weight | 9 kg |
| Batch Volume | 100–5,000 mL (tested in water |
| Protection Rating | IP55 |
| Insulation Class | F |
| Explosion-Proof | No |
| Rotor/Stator Material | Stainless Steel SUS304 or optional SUS316L |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C50 |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Flow Rate | 15–50 L/h |
| Minimum Sample Volume | 25 mL |
| Drive Type | Pneumatic Dual-Piston |
| Safety | Auto-circuit cutoff with 20% transient overpressure tolerance |
| Construction Material | ASTM-certified 316L stainless steel |
| Sterilization | Direct steam-in-place (SIP), O-ring-free fluid path |
| Compliance | FDA 21 CFR Part 11-ready architecture, GMP-compliant design |
| Optional Accessories | Extrusion filter, heat exchanger |
| Instrument Category | High-Pressure Cell Disruptor |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C55 |
| Pressure Range | 0–30,000 psi (0–207 MPa) |
| Flow Rate | 15–50 L/h |
| Minimum Sample Volume | 7 mL |
| Drive Type | Pneumatic Dual-Piston |
| Compliance | GMP, FDA 21 CFR Part 11–ready architecture, ASME BPE–compatible materials |
| Construction Material | Electropolished 316L stainless steel |
| Sterilization | SIP/CIP-capable, O-ring–free fluid path |
| Safety | Auto-cutoff circuit protection, transient overpressure tolerance up to 20% |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, ON |
| Model | EmulsiFlex-D20 |
| Operating Pressure | 35,000 psi (2,413 bar) / Max Continuous: 30,000 psi (2,070 bar) |
| Flow Rate | 20 L/h |
| Minimum Sample Volume | 50 mL |
| Sample Hold-up Volume | <1 mL |
| Drive Type | Electric Single-Plunger Pump |
| Dimensions (W×D×H) | 730 × 600 × 640 mm |
| Weight | 120 kg |
| Power Supply | 3-phase, 50/60 Hz, 230/400 V |
| Construction Material | ASTM A240 316L stainless steel + ceramic wear components |
| Sterilization | Direct steam-in-place (SIP) compatible |
| Compliance | GMP-compliant design, FDA 21 CFR Part 11–ready software architecture, USP <1043> and ISO 22442-1 applicable for bioprocess equipment qualification |
| Brand | Branson |
|---|---|
| Origin | USA |
| Model | CLP-DCX |
| Instrument Type | Continuous-Flow Ultrasonic Cell Disruptor |
| Output Power | 1250 W / 2500 W / 4000 W (max) |
| Frequency | 20 kHz ± 0.5 kHz |
| Input Voltage | 230 V AC, 50/60 Hz |
| Max Current Draw | 7 A / 14 A / 25 A |
| Flow Rate | Up to 10 GPM (45 L/min) |
| Treatment Chamber Volume | 150 mL (continuous recirculation mode, min. recommended batch: 5 L) |
| Amplitude Range | 10–100% (closed-loop controlled) |
| Temperature Control | External jacketed cooling, sample temp. maintained at 3–5 °C above coolant inlet |
| Probe Diameter | 38 mm |
| Amplification Ratio | 1:1.5 or 1:2 (aluminum booster) |
| Generator | CR-20S |
| Compliance | CE, UL 61010-1, RoHS |
| Brand | Branson |
|---|---|
| Origin | USA |
| Model | LLP-DCX |
| Instrument Type | Ultrasonic Cell Disruptor |
| Output Power | 1250 W / 2500 W / 4000 W (max) |
| Frequency | 20 kHz |
| Voltage | 230 V AC, 50/60 Hz |
| Processing Volume | 5–20 L |
| Amplitude Control | 10–100% (closed-loop, patented) |
| Temperature Management | Integrated jacketed cooling system |
| Control System | PLC-based touchscreen interface with real-time diagnostics |
| Dimensions (W×D×H) | 1270 × 840 × 1930 mm |
| Probe Drive Motor | 120 W, variable-speed vertical lift |
| Rotation Motor | Bidirectional tank rotation |
| Safety Protections | 6-point generator protection (overcurrent, frequency drift, overheating, impedance mismatch, arc detection, duty cycle limit) |
| Remote Diagnostics | Branson SecureLink™ service port enabled |
| Brand | Branson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MLP-DCX |
| Instrument Type | Ultrasonic Cell Disruptor |
| Frequency | 20 kHz |
| Output Power | 1250 W / 2500 W / 4000 W (model-dependent) |
| Amplitude Range | 10–100% adjustable |
| Probe Material | Ti-7Al-4Mo alloy with carbide surface treatment |
| Probe Amplification Ratios | 1:1.5 or 1:2 (aluminum booster) |
| Processing Volume | 1–5 L |
| Power Supply | 230 V AC, 50/60 Hz |
| Protection Features | Overload, frequency drift, thermal, current, impedance, and arc fault detection |
| Control Interface | PLC-based touchscreen HMI |
| Diagnostics | Built-in startup self-test, real-time online monitoring, remote diagnostic port |
| Cooling | Segregated internal forced-air cooling system |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Branson |
|---|---|
| Origin | Mexico |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SFX150 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 150 W |
| Operating Frequency | 40 kHz |
| Sample Volume Range | 0.1–150 mL |
| Pulse Duration Resolution | 0.01 s |
| Amplitude Adjustment Range | 10–100% |
| Programmable Methods | 20 user-defined protocols |
| Energy Control Range | 1–999,999 J |
| Time Control Range | 0.01 s to 99 h 59 min 59 s |
| Input Voltage | AC 200–240 V, 50/60 Hz |
| Standard Probe | 3 mm (1/8″) titanium alloy (Ti-7Al-4V) |
| Dimensions (W×D×H) | 348 × 203 × 242 mm |
| Weight | 6.35 kg |
| Brand | Branson |
|---|---|
| Origin | Mexico |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SFX250 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 250 W |
| Operating Frequency | 20 kHz |
| Sample Temperature Range | 0–100 °C |
| Sample Volume Capacity | 200 µL – 500 mL |
| Throughput | Single-sample processing per cycle |
| Brand | Branson |
|---|---|
| Origin | Mexico |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFX550 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 550 W |
| Operating Frequency | 20 kHz |
| Sample Temperature Range | 0–100 °C |
| Sample Volume Capacity | 200 µL – 1000 mL |
| Throughput | Single-sample processing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-450D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Output Power | 400 W (continuously adjustable) |
| Frequency | 20 kHz |
| Voltage | 230 V AC, 50/60 Hz |
| Max Current | 4 A |
| Timer Range | 1 s – 9 h 59 min 59 s |
| Pulse Duration | 0.1 – 9.9 s |
| Interval Duration | 0.1 – 9.9 s |
| Amplitude Control | 10–100% (1% increments) |
| Sample Volume Capacity | 10 mL – >1000 mL |
| Probe Material | Grade 7–4 Ti-6Al-4V Titanium Alloy |
| Weight | 10.1 kg |
| Interface | RS-232 serial port |
| Data Storage | 20 user-programmable protocols |
| Display | Digital LCD with real-time energy bar graph |
| Remote I/O | Yes, for external temperature/power monitoring |
| Diagnostic Function | Automatic self-test at power-on |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-250D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Output Power | 200 W (continuously adjustable) |
| Operating Frequency | 20 kHz |
| Voltage Rating | 230 V AC, 50/60 Hz |
| Max Current | 4 A |
| Standard Probe | 1/2″ (13 mm) titanium alloy probe |
| Minimum Sample Volume | 0.25 mL (with optional 1/8″ probe) |
| Standard Processing Volume | 10–250 mL |
| Adjustable Amplitude Range | 10–100% |
| Pulse Duration | 0.1–9.9 s |
| Pulse Interval | 0.1–9.9 s |
| Timer Range | 1 s–9 h 59 min 59 s |
| Data Storage | 20 user protocols |
| Interface | RS-232 serial port |
| Weight | 10.1 kg |
| Brand | Branson |
|---|---|
| Origin | Mexico |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFX150 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 150 W |
| Operating Frequency | 40 kHz |
| Sample Volume Range | 0.1–150 mL |
| Amplitude Adjustment | 10–100% |
| Pulse Duration Resolution | 0.01 s |
| Energy Control Range | 1–999,999 J |
| Time Control Range | 0.01 s – 99 h 59 min 59 s |
| Programmable Methods | 20 stored protocols |
| Standard Probe | 1/8″ (3 mm) Titanium Alloy (7–4), Solid Tip |
| Input Voltage | AC 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 348 × 203 × 242 mm |
| Weight | 6.35 kg |
| Brand | Branson |
|---|---|
| Origin | USA |
| Model | SLPt |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 40 kHz |
| Output Power | 150 W (continuously adjustable) |
| Amplitude Control | 10–100% in 1% increments |
| Pulse Duration | 0.1–9.9 s |
| Total Time Setting | 1 s – 99 h |
| Energy Range | 1–10,000 J |
| Standard Probe | 1/8″ (3 mm) microtip |
| Sample Volume Capacity | 0.25–10 mL |
| Input Voltage | 230 V AC, 50/60 Hz |
| Max Current | 4 A |
| Weight | 7.71 kg |
| Auto-Tuning & Memory (AT/M) | Yes |
| Diagnostic Self-Test | On power-up |
| Compliance | Designed for GLP-compliant labs |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SLPe |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 40 kHz |
| Output Power | 150 W (continuously adjustable) |
| Voltage Rating | 230 V AC, 50/60 Hz |
| Max Current | 4 A |
| Standard Probe | 1/8" (3 mm) microtip |
| Sample Volume Range | 0.25–10 mL |
| Amplitude Control | 10–100% in 1% increments |
| Time Setting Range | 1 s – 99 h |
| Energy Setting Range | 1–10,000 J |
| Pulse Duration | 0.1–9.9 s |
| Auto-Tuning & Memory (AT/M) | Yes |
| Diagnostic Self-Test | On power-up |
| Weight | 7.71 kg |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 04714-51 |
| Output Power | 130 W |
| Frequency | 20 kHz |
| Probe Tip Diameter | 6 mm |
| Sample Volume Range | 10–50 mL |
| Dimensions (L×W×H) | 115 × 250 × 320 mm |
| Net Weight | 3 kg |
| Timer Range | 1 s – 10 min (digital) |
| Pulse Mode | On/Off cycles adjustable from 0.1 s to 10 s each |
| Transducer Type | CV18 PZT piezoelectric converter (Ø32 mm × 146 mm, 340 g) |
| Probe Material | Ti-6Al-4V titanium alloy |
| Input Voltage | 220 V / 50 Hz |
| Display | 3-digit LCD wattmeter |
| Remote Control | Footswitch interface provided |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | IN-FT300 |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–300 W |
| Sample Volume Capacity | 0.1–300 mL (with interchangeable titanium alloy probes) |
| Pulse Control Resolution | 0.1 s (on/off/total time) |
| Temperature Monitoring Range | 0–99.9 °C (contact-type sensor) |
| Display | 10.1″ HD capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Transducer Housing | Aerospace-grade magnesium-aluminum alloy |
| Data Storage | 256 programmable protocols |
| Compliance | CE-marked design principles |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-16S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 22–2200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Parallel Channels | 16 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Safety Protections | Overtemperature, overcurrent, overtime, and fault alarm |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |