Chemical Analysis Instruments
Filter
Showing 3001–3030 of 10716 results
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F80 |
| Application Scope | General-Purpose |
| EPC Generation | 4th-Generation Electronic Pressure Control (EPC) |
| Column Oven Design | Platinum Resistance Temperature Sensor with Unobstructed Mounting |
| Safety Features | Dual-Temperature Monitoring, Hydrogen Auto-Shutoff, DC Heating, Flame-Retardant Materials |
| Detector Options | Multiple Configurable Detectors |
| Flow Path Flexibility | Multi-Valve/Multi-Column Support, Deans Switch, Micro-Flow Center-Cut, Comprehensive 2D-GC Ready |
| Software Platform | MyLab Chromatography Workstation (Web-Based Remote Access via PC/Tablet/Smartphone) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fortelab |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CP300 |
| Price Range | USD 1,400 – 7,000 (based on current exchange rate) |
| Instrument Type | Secondary Thermal Desorber, Thermal Desorption Unit |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | FoodScan 2 |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 400–1100 nm |
| Sample Throughput | 15–25 seconds per sample |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission and Reflectance |
| Chemometric Software Engine | Artificial Neural Network (ANN) Calibration |
| Regulatory Certification | AOAC Official Method of Analysis™ 983.18 |
| Application Scope | Raw and processed meat, poultry, and aquatic products (porcine, bovine, avian, etc.) |
| Key Analytes | Fat, Protein, Moisture, Collagen, Salt (Cl⁻ basis), Lean Meat Content |
| Optional Extensions | Saturated Fatty Acids, Ash, Sodium-based Salt, Water Activity, Color Parameters |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Grain & Flour |
| Instrument Type | Laboratory Near-Infrared Spectrometer |
| Principle | Grating-based Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 60 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | ANN (Artificial Neural Networks), PLS (Partial Least Squares) |
| Path Length Control | Motorized, 6–33 mm auto-adjustable |
| Subsample Capacity | 1–30 (standard: 10) |
| Analysis Time | 60 s (10 subsamples, including bulk density) |
| Compliance | EN 15948, IP54 dust- and splash-resistant enclosure |
| Patents | US 4,944,589 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec™ Sofia |
| Instrument Type | Portable Near-Infrared Spectrometer |
| Wavelength Range | 850–1050 nm |
| Measurement Mode | Transmission NIR |
| Analysis Time | ~3 minutes for 10 subsamples |
| Dimensions (W × D × H) | 255 × 390 × 295 mm |
| Weight | 9 kg |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | <93% RH (non-condensing), up to 100% cyclic |
| Power Supply | 100–240 V AC, 50–60 Hz, Class I with earth grounding |
| EMC Environment | Light industrial, agricultural & mobile machinery |
| Sample Preparation | None required (whole-grain analysis) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 – 210 mg N |
| Distillation Flow Rate | ~40 mL/min |
| Repeatability | ≤1% RSD |
| Recovery Rate | >99.5% (for 1–200 mg N) |
| Power Consumption | 3000 W |
| Dimensions (L×W×H) | 500 mm × 480 mm × 760 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Kjeltec™ 9 Distillator |
| Instrument Type | Kjeldahl Nitrogen Distillation Unit |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–210 mg N |
| Distillation Time | 3.5 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | Solids: 0.2–2 g |
| Semi-solids | 2–5 g |
| Liquids | 10–25 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 3000 W |
| Dimensions (L×W×H) | 500×480×790 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatScan |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 850–1050 nm |
| Scan Time | 45 seconds per sample (including 15 subsamples) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Artificial Neural Network (ANN)-based calibration |
| Sample Form | Homogenized meat mince (pork, poultry, beef, lamb) |
| Output Parameters | Fat content (%), Moisture content (%) |
| Weight | 12 kg |
| Compliance | Designed for GLP-compliant environments |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Benchtop |
| Design | Modular |
| Sample Throughput | 60 samples per auto-sampler tray |
| Core Technology | Laser-Induced Breakdown Spectroscopy (LIBS) |
| Target Elements | Ca, Mg, P, K, Na, S (macronutrients) |
| Sample Forms | Fresh grass, silage (maize, barley, sorghum), alfalfa/legumes, hay, semi-dry forage, straw, clover, mixed hay |
| Reagent-Free Operation | Yes |
| Compliance Context | Designed for agricultural QA/QC workflows aligned with ISO 17025–accredited laboratory practices and feed industry GLP requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DA1650 |
| Instrument Type | Laboratory Benchtop |
| Optical Principle | Grating-based Diode Array Scanning |
| Wavelength Range | 1100–1650 nm |
| Scan Time | 1 minute per spectrum |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance, Transmission (for liquids) |
| Chemometrics Software | WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 F |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating Scanning |
| Wavelength Range | 850–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Interface | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Pre-Standardized, Inter-Instrument Transferable Calibration |
| Language Options | English or Chinese UI & Network Management Software |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capabilities in WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Identification | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Inter-instrument Transferable Standardization |
| Language Options | English or Chinese GUI (configurable) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS™ DS2500 L |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Time | <40 s per sample |
| Data Sampling Interval | 10 s |
| Measurement Mode | Transmission (for liquids) |
| Chemometrics Software | WinISI |
| IP Rating | IP54 |
| Temperature Control | Automatic, Closed-Loop Sample Thermal Regulation |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Feed Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Optical Principle | Grating-based non-scanning diode array detector |
| Wavelength Range | 1100–1650 nm |
| Analysis Speed | Real-time |
| average analysis time per result | 2–3 seconds |
| Sampling Interval | Real-time |
| Measurement Mode | NIR transmission/reflection (process-integrated) |
| Chemometrics Software | ISIscan NOVA™ Instrument Control Software |
| Sample Interface | Direct-coupled flow-through window, no bypass required |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Soybean Meal Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Grating-based diode array (non-scanning) NIR spectroscopy |
| Wavelength Range | 1100–1650 nm |
| Analysis Time per Result | 2–3 seconds (real-time) |
| Sampling Mode | Diffuse reflectance and/or transmission |
| Chemometrics Software | ISIscan NOVA™ Instrument Control |
| Data Acquisition Interval | 2–3 seconds (real-time) |
| Compliance Ready | Designed for integration with industrial process control systems (OPC UA/DA), supports audit-ready data logging per GLP/GMP-aligned workflows |
| Brand | FOSS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Model | SINO KT8400 |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Sample Throughput | Compatible with 20-position autosamplers (e.g., FOSS 8420/8460) |
| Safety Features | SAFE™ steam-controlled distillation, interlocked transparent safety door, integrated temperature-controlled distillate cooling |
| Software Options | FOSS Compass LIMS-ready software with GLP-compliant audit trail, network printer/tare balance integration |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AFS-10U |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CS5000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.00001–12.0 wt% |
| Sulfur Range | 0.00001–45.0 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1.0 ppm (C/S) or RSD ≤ 0.5% (C), ≤ 1.0% (S) |
| Analysis Time | 20–40 s |
| Dimensions | 650 × 790 × 920 mm (W×D×H) |
| Weight | 150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, voltage fluctuation < ±0.2% |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product | Yes |
| Model | CS5000 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.00001–12 wt% |
| Sulfur Range | 0.00001–45 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1.0 ppm |
| Analysis Time | 20–40 s |
| Furnace Output Power | Adjustable (0–2.5 kW typical for HF induction) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | E5000 |
| Instrument Type | Benchtop |
| Excitation Source | High-Power Numerically Controlled Arc |
| Detector | CCD Array |
| Focal Length | 400 mm |
| Grating Grooves | 2400 lines/mm |
| Wavelength Range | 190 nm – 680 nm |
| Detection Mode | Full-Spectrum Simultaneous Acquisition |
| Optical Design | Paschen–Runge Mount |
| Cooling | Water-Cooled Electrodes & Arc Source |
| Safety Interlocks | Real-Time Monitoring of Cooling Water Flow, Exhaust Ventilation, and Torch Chamber Door Status |
| Software Compliance | Supports Audit Trail, User Access Control, and Method Validation per GLP/GMP Requirements |
| Data Acquisition | Overflow-Protected CCD with Dynamic Integration |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop |
| Excitation Source | High-Power Programmable DC Arc |
| Detector | Back-Illuminated CCD Array |
| Focal Length | 400 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 190–680 nm |
| Spectral Coverage | Full-Spectrum Simultaneous Acquisition |
| Optical Design | Paschen-Runge Mount with Fixed, Thermally Stabilized Vacuum- or Purged-Optics Chamber |
| Cooling | Integrated Water-Cooled Electrode & Arc Source |
| Safety Interlocks | Real-Time Monitoring of Cooling Flow, Exhaust Ventilation, Torch Chamber Door Status, and Thermal Sensors |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable Gas Chromatograph |
| Application Scope | General-purpose Environmental Emission Monitoring |
| Compliance Standards | HJ 1012, HJ 38, HJ 604, GB 37822–2019 |
| Detection Principle | High-Temperature Heated Sample Transfer + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for Total Hydrocarbons, Methane, and BTEX |
| Integrated Power Supply | Rechargeable Lithium Battery (≥4 h continuous operation with heated line) |
| Data Output | Raw Chromatograms & Quantitative Results Exportable in Standard Formats (e.g., .csv, .cdf) |
| Certification | China Metrology Accreditation (CPA), Compatible with CMA Reporting Requirements |
| Sample Introduction | Dual-Stage Filtered Sampling Pump + Fixed-Volume Loop Injection |
| Column Configuration | Capillary GC Column Optimized for C1–C8 Hydrocarbons |
| Detector Temperature | Up to 180 °C |
| Sample Line Temperature | Heated to 180 °C |
| Dimensions & Portability | Integrated All-in-One Chassis with Carrying Handle |
| Optional Accessories | Android Tablet Interface, High-Pressure Gas Cylinders, Metal Hydride Hydrogen Generators |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 7000 |
| Quotation | Upon Request |
| Deployment Mode | Mobile (Vehicle-Mounted) |
| Mass Range | 2–260 amu |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb (µg/L) |
| Precision | RSD ≤ 0.5% |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤ 0.007 nm @ 200 nm |
| Spectral Coverage | Simultaneous multi-element analysis across 72 elements including major metals and non-metals |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ICP-5500 |
| Detector | High-resolution overflow-resistant CCD |
| RF Source | All-solid-state self-excited 27.12 MHz generator |
| Optical System | Precision thermostatically controlled Czerny–Turner monochromator with holographic grating |
| Gas Control | Integrated automatic argon flow management module |
| Standby Mode | iStandby (reduces Ar consumption by >50%) |
| Calibration | Real-time full-spectrum calibration using interference-free Ne emission lines |
| Sample Introduction | Multi-channel high-precision peristaltic pump with integrated nebulizer and spray chamber |
| Compliance | Designed to support ISO/IEC 17025, ASTM D1976, EPA Method 200.7, USP <232>/<233>, and GLP/GMP data integrity requirements |
| Software | FPI-SpectraSuite v4.x with 21 CFR Part 11-compliant audit trail, electronic signatures, and raw data archiving |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | LGA Series |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector | Charge-Coupled Device (CCD) |
| Optical Configuration | Paschen-Runge Mount |
| Wavelength Range | Configurable (Typical Range: 130–800 nm) |
| Number of Simultaneous Channels | Multi-channel (CCD-based full-spectrum acquisition) |
| Argon Purge System | Sealed argon recirculation with four-way purging |
| Operating Environment | Industrial floor and laboratory settings |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, and GB/T 4336 standards |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | Configurable |
| Optical Configuration | Paschen–Runge Mount |
| Environmental Operation | Argon-purged Sealed Optical Chamber |
| Sample Interface | Open-type Spark Stand with Quadruple Argon Purge |
| Temperature Control | Thermostatically Stabilized Optics Chamber |
| Software Features | Real-time Drift Correction, Intelligent Calibration Curve Matching, Grade Identification, CE/CRE Calculation, QC Limit Enforcement, System Self-Diagnosis |
| Compliance Context | Designed for GLP-compliant metal analysis workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | CMOS-based CCD array |
| Optical Configuration | Paschen-Runge mount |
| Wavelength Range | Configurable (typically 130–800 nm) |
| Number of Simultaneous Channels | Up to 60 (software-defined) |
| Argon Purge System | Sealed argon-circulation optical chamber with four-way purge |
| Operating Environment | Industrial workshop / QC lab (IP54-rated spark stand) |
