Chemical Analysis Instruments
Filter
Showing 2971–3000 of 10705 results
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-SDD |
| Form Factor | Benchtop |
| Elemental Range | Al (Z=13) to U (Z=92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | ≤140 eV (Mn Kα) |
| Repeatability | ≤5% RSD |
| Sample Stage | Motorized XYZ with Programmable XY Translation and Z-Axis Lift |
| X-ray Source | Microfocus Tungsten Anode Tube with Beryllium Window |
| High Voltage | 3-step Adjustable (up to 50 kV) |
| Filter Options | 6 Interchangeable Primary Filters |
| Collimators | Motorized, Switchable Apertures |
| Optical Alignment | Integrated HD Video System with 20× Digital Zoom, Crosshair Overlay, and Laser Spot Locator |
| Software Platform | WinFTM® v8.x (FDA 21 CFR Part 11 Compliant, Audit Trail Enabled, GLP/GMP-Ready) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJA-1 |
| Price Range | USD 700 – 1,400 (est.) |
| Instrument Type | Multifunctional Electrochemical Analyzer |
| Voltage Input Range | ±1999.9 mV |
| Minimum Resolution | 0.1 mV |
| Accuracy | ±0.025% of reading + 2 digits |
| Input Impedance | >10¹² Ω |
| Sampling Rate | 3–10 Hz |
| Interface | RS-232 (USB adapter optional) |
| Software Platform | Windows-based (11 dedicated application modules) |
| Data Storage | ASCII text files with date-stamped naming convention (e.g., “pHr_YYYY_MM_DD.TXT”, “SPS_YYYY_MM_DD.TXT”) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FJA-6 |
| Price | Upon Request |
| Form Factor | Benchtop |
| Conductivity Range | 1 μS to 100 mS (5 auto-ranging spans) |
| Accuracy | ±1.5% of reading |
| Temperature Compensation Error | <±2% |
| Stability | ±0.1% FS ±1 digit/hour |
| Dimensions | 183 × 130 × 60 mm |
| Weight | <0.5 kg |
| Operating Temp | 0–45 °C |
| RH Limit | ≤85% |
| Power Supply | 5 V DC |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJA-8 |
| Price Range | USD 430–710 (FOB) |
| Measured Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Portability | Handheld |
| Application Environment | Field, Laboratory, Soil Monitoring |
| Conductivity Range | 1 µS/cm – 10 mS/cm (5 auto-ranging decades) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–0.3 mol/L |
| Temperature Range | 0–60 °C |
| Accuracy | ±2% of reading ± 0.01 µS/cm |
| Minimum Resolution | 0.001 µS/cm |
| Data Storage | 200 readings |
| Power Supply | Rechargeable 8.4 V Li-ion battery |
| Dimensions | 183 × 130 × 60 mm |
| Weight | < 0.5 kg |
| Operating Temp. | 0–45 °C |
| Relative Humidity | ≤85% RH |
| Interface | USB for PC data export |
| Software Support | FJA-6 Series PC Application Suite (data logging, calibration history, CSV export) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–120 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 145 psi (1.0 MPa) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU @ 254 nm |
| Fraction Collection | X-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes) |
| Detection Options | Dual-Wavelength UV Detector (D₂ + Tungsten lamp) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000Pro |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–200 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 200 psi (13.8 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Flow Path Configuration | Binary Solvent Delivery |
| Fraction Collection | X-Y Robotic Matrix (135-tube capacity, standard 15 × 150 mm tubes) |
| Detection Options | UV/Vis Detector (D₂ + Tungsten lamp), optional ELSD |
| Column Compatibility | Normal-phase (e.g., silica, 12 g & 25 g), reversed-phase (C18, 40 g), and empty loading columns (12 g) |
| Software Features | Method-based fraction triggering, peak integration & quantitation, audit trail, user management, lamp life monitoring, intensity calibration, TLC-guided method recommendation |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | FlashDoctor-1500 |
| Instrument Type | Medium-Pressure Flash Chromatography System |
| Application Scope | General-Purpose Preparative Purification |
| Flow Rate Range | 0–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Accuracy | ±1.5% |
| Injection Capacity | Manual or Optional Autosampler |
| Injection Volume Range | 0.1–50 mL (via syringe or loop) |
| Temperature Control | Ambient-only (no active column oven) |
| Wavelength Range (DAD) | 200–800 nm |
| Data Acquisition Rate | Up to 20 Hz |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-2000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | <1.5% |
| Maximum Pressure | 300 psi (2.07 MPa) |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Spectral Bandwidth | 8 nm |
| Flow Cell Path Length | 0.3 mm |
| Detection Modes | UV-Vis (DAD), optional ELSD |
| Fraction Collection | 2D X-Y robotic collector (135-tube capacity, standard 15 × 150 mm tubes) |
| Column Compatibility | Reversible normal-phase and reversed-phase (e.g., C18), flash columns up to 40 mm ID |
| Software Compliance | Audit trail, user management, electronic signature support per FDA 21 CFR Part 11 requirements |
| System Architecture | Integrated benchtop unit, ventilated cabinet compatible |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Flex-CLUE |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FLEXA |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–50/100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision | ±0.1% |
| Maximum Pressure | 30/20 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU |
| Data Acquisition Frequency | 3 Hz |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR2020 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 270–1100 nm |
| Sample Volumes/Cup Capacity | 5 mL / 100 cups, 8 mL / 180 cups, 10 mL / 270 cups |
| Reagent Positions | 100, 180, or 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Flucon Fluid Control GmbH |
|---|---|
| Origin | Germany |
| Type | Benchtop Laboratory Instrument |
| Model | EPSILON+ |
| Compliance | DIN 51111 |
| Conductivity Range | 2 nS/m – 600 µS/m |
| TDS Range | 1–10 (unitless, ppm-equivalent scale) |
| Resistivity Range | 0.3 – 10,000 Ω·m |
| Temperature Range | −20 °C to +180 °C |
| Accuracy | ±1% (for κ > 20 nS/m) |
| Minimum Conductivity Resolution | 2 nS/m |
| Dielectric Constant (εᵣ) Range | 1–10 |
| Dielectric Loss Factor (tan δ) Range | 0.3–10,000 |
| Measurement Time | ~15 s |
| Sample Volume | 8 mL |
| Sensor Material | Stainless steel, PEEK, polyimide |
| Temperature Sensor | Integrated PT100 (±0.1 °C) |
| Housing Dimensions | 235 × 150 × 370 mm (W × H × D) |
| Power Supply | 110–240 V AC, max. 30 W |
| Interface | RS-232 (USB adapter included) |
| Display | 4×16-character blue-backlit LCD |
| Output Signals | 0–10 V analog or 4–20 mA (optional) |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FLUO-IMAGER |
| Pricing | Upon Request |
| Key | Brand: Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Model | TY-Ca08 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Power Consumption | ≤30 W |
| Dimensions (W×D×H) | 468 × 368 × 136 mm |
| Weight | 13.8 kg |
| Analysis Time | 15 × n seconds (n ∈ ℕ) |
| recommended default | 30 s |
| CaO Quantification Range | 0.1–100 wt% |
| CaO Precision (Standard Deviation) | ≤0.09% |
| Sample Preparation | Manual toggle-type tablet press with adjustable die cavity height |
| Compliance | Designed for routine industrial QA/QC per ISO 29581-1 (cement), ASTM C114 (standard test methods for chemical analysis of hydraulic cement) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | OLED/PeLED |
| Angular Range | −90° to +90° |
| Spectral Range | 360–1100 nm |
| Spectral Resolution | 2.5 nm |
| Signal-to-Noise Ratio | 300:1 |
| Voltage Range | ±20 V |
| Current Range | ±120 mA |
| Current Resolution | <100 pA |
| Polarizer Rotation | 0–360° (continuous) |
| Sample Stage | 40 × 40 mm² |
| PL Excitation Wavelength | 275–405 nm (default 365 nm) |
| PL Spot Size | 5 × 3 mm² |
| Dimensions | 50 × 29 × 24 cm³ |
| Weight | 18 kg |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PHELOS |
| Angular Range | –90° to +90° |
| Spectral Range | 360–1100 nm |
| Spectral Resolution | 2.5 nm |
| Angular Resolution | < 0.5° |
| SNR | 300:1 |
| Voltage Range | ±20 V |
| Current Range | ±120 mA |
| Current Resolution | < 100 pA |
| Polarizer Rotation | 0–360° (continuous) |
| Sample Stage | 40 × 40 mm² |
| PL Excitation Wavelength | 275–405 nm (default 365 nm) |
| PL Spot Size | 5 × 3 mm² |
| Dimensions | 50 × 29 × 24 cm³ |
| Weight | 18 kg |
| Brand | Axcend |
|---|---|
| Origin | USA |
| Model | Focus LC |
| Instrument Type | Portable Capillary HPLC |
| Detection Principle | UV Absorbance (254 nm standard) |
| Max Operating Pressure | 10,000 psi |
| Power Input | AC 100–240 V, 50/60 Hz, 1.4 A |
| Battery | 12 V DC, 126 Wh LiFePO₄ |
| Runtime | >10 hours per charge |
| Cycle Life | >2,000 charge/discharge cycles |
| Solvent Consumption | <10 mL/week (typical operational use) |
| Cartridge-Based System | Tool-free, modular hardware reconfiguration |
| Brand | FocusSens / Beijing Michem Technology Ltd. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | MiX5 |
| Pricing | Available Upon Request |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-100 |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | (-2000.0 to +2000.0) mV, (0.00 to 14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 1 mV (mV mode), 0.01 pH (pH mode) |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Input Impedance | ≥10¹⁵ Ω |
| Temperature Range (with optional thermostat) | -15 °C to +85 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy (optional) | ±0.5 °C |
| Minimum Dispense Volume | 0.02 mL |
| Titration Control Precision | ±0.01 mL |
| Measurement Modes | Dynamic titration, Equivalence-point titration, Fixed-volume titration, Direct pH measurement |
| Interface Options | RS232C, Printer port (for optional thermal mini-printer) |
| Data Output | Real-time titration curve plotting, PC connectivity for process monitoring and post-analysis |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-2S |
| Titration Mode | Fully Automated |
| Method Type | Dual-Mode (Coulometric & Volumetric Karl Fischer) |
| Measurement Resolution | 0.01 μA |
| Water Content Range | 0.01 mg to 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 μA |
| Drift Compensation | Automatic background drift correction (drift <5 µg H₂O/min) |
| Detection Limit | 0.01 mg H₂O |
| Sample Forms | Liquids, solids, gases, pastes |
| Display & Interface | Bilingual (Chinese/English) LCD with real-time titration curve visualization |
| Data Output | GLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability |
| Software | Embedded titration monitoring software with firmware upgrade support |
| Compliance | Designed for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3D |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | 0–2000 mV |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.2 mV or ±0.1% of reading |
| Titration Resolution | 1/100,000 |
| Temperature Control | PID with dynamic compensation, external heating/cooling interface |
| Display | Large backlit Chinese LCD |
| Communication | RS-232 serial interface |
| Software Platform | Windows-based monitoring software |
| Titration System | Piston-driven burette with anti-diffusion titration tip |
| Burette Mounting | Push-in modular design |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3S |
| Titration Mode | Fully Automatic |
| Method Principle | Volumetric & Coulometric Karl Fischer Titration |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±10 ppm |
| Minimum Dispensing Volume | 0.1 µL (1/20000 of burette volume) |
| Titration Control Precision | 0.1 µL |
| Polarization Voltage Output | 0–2550 mV (10 mV step, <±3% error) |
| Max Polarization Current | 5 mA |
| Current Range | 0–200 µA |
| Effective Current Accuracy | ±0.1 µA |
| Drift Compensation | Auto/manual background subtraction |
| Data Output Compliance | GLP/GMP-compliant reporting format |
| Interface | RS-232C (printer & PC connection) |
| Method Storage | 100 protocols |
| Optional | Dead-stop titration capability with accessory kit |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −1999.0 to +1999.0 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 1 mV (mV mode) |
| Titration Accuracy | ±0.3 mV ±1 digit over 3 h |
| Titration Resolution | 1/20000 |
| Regulatory Compliance | Certified per JJG 814–2015 (Chinese National Metrological Verification Regulation), GMP-compliant design |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-400 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measuring Range | mV: −2000 to +2000 mV |
| pH | 0.00 to 20.00 |
| Temperature | 0.0 to 125.0 °C |
| Resolution | pH: 0.01 |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Input Current (Typical) | −3 × 10⁻¹⁵ A |
| Accuracy (mV) | ±0.5 mV |
| Minimum Dispensing Volume | 0.0625 µL |
| Titration Modes | Dynamic, Equivalence-point, Fixed-volume, pH-stat, and Direct pH Measurement |
| Method Storage Capacity | 30 pre-programmed titration methods |
| Result Storage Capacity | 100 titration records |
| Display & Interface | Dual-language (Chinese/English) LCD interface |
| Software | Embedded titration monitoring software with firmware update capability |
| Compliance Support | GLP/GMP-compliant data output and audit trail generation |
| Titration Precision | ±0.01 pH over 3 h |
| Titration Resolution | 1/20000 |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-600 |
| Measurement Range | ±2400 mV / ±20 pH |
| Meter Accuracy | 0.01 mV / 0.001 pH |
| Meter Resolution | 0.01 mV / 0.001 pH |
| Titration Accuracy | ±10 µL (at 10 mL) |
| Titration Resolution | 1/20000 |
| Overall Accuracy | ±0.1% |
| Precision | ≤0.1% |
| Input Impedance | ≥3×10¹² Ω |
| Input Current | ≤1×10⁻¹² A |
| Temperature Range | 0–125 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Humidity Range | 10–85% RH |
| Humidity Resolution | 1% RH |
| Humidity Accuracy | ±5% RH |
| Titration Speed | 1–99 mL/min (adjustable) |
| Titration Tube Mounting | Tool-free replacement |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZDJ-600S |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ≤0.2% RSD |
| Minimum Dispensing Volume | 5 µL |
| Burette Precision | 1/20,000 |
| Burette Capacity | 10 mL (standard) |
| Burette Accuracy | ±10 µL @ 10 mL |
| Polarization Current Range | 0–200 µA |
| Polarization Voltage Range | 0–2550 mV |
| Polarization Voltage Step | 10 mV |
| Effective Current Accuracy | Better than ±0.1 µA |
| Repeatability (Pure Water) | <1% RSD |
| Standardization Repeatability | ±0.5% of mean across three consecutive runs |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | ZY-600U |
| Instrument Type | TLC Imaging System |
| Operation Mode | Fully Automatic |
| Measurement Mode | Transmitted Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | UV Lamps (254 nm & 365 nm), White Light Lamp (400–750 nm) |
| Detector | High-Sensitivity CCD Camera |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.01 cm⁻¹ |
| Spatial Resolution | 0.01 cm |
| Imaging Wavelengths | UV254/UV365 (transmission), Visible (400–750 nm) |
| Sample Stage Dimensions | 200 mm × 200 mm |
| Scanning Speed | 100 mm/s |
| Image Sensor | 1280 × 1024 pixels, high-frame-rate acquisition |
| UV Transmission Efficiency | ≥92% |
| OS Compatibility | Windows 2000/XP |
| Interface | USB 2.0 |
| Rf Calculation Accuracy | ≤0.01 cm repeatability |
| Inter-unit Measurement Variation | ≤0.5% |
| Data Export Formats | JPG, BMP, TIFF, PNG |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F70Pro |
| Application Scope | General-Purpose Analysis |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F80 |
| Application Scope | General-Purpose |
| EPC Generation | 4th-Generation Electronic Pressure Control (EPC) |
| Column Oven Design | Platinum Resistance Temperature Sensor with Unobstructed Mounting |
| Safety Features | Dual-Temperature Monitoring, Hydrogen Auto-Shutoff, DC Heating, Flame-Retardant Materials |
| Detector Options | Multiple Configurable Detectors |
| Flow Path Flexibility | Multi-Valve/Multi-Column Support, Deans Switch, Micro-Flow Center-Cut, Comprehensive 2D-GC Ready |
| Software Platform | MyLab Chromatography Workstation (Web-Based Remote Access via PC/Tablet/Smartphone) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fortelab |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CP300 |
| Price Range | USD 1,400 – 7,000 (based on current exchange rate) |
| Instrument Type | Secondary Thermal Desorber, Thermal Desorption Unit |