Chemical Analysis Instruments
Filter
Showing 871–900 of 4337 results
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400/2100 nm |
| Scan Speed | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Stray Light | VNIR 5000:1 (0.02%), NIR 10000:1 (0.01%) |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | 512-pixel Si array (350–1000 nm), TE-cooled InGaAs gradient-index arrays (1001–1800 nm & 1801–2500 nm) |
| Interface | 10/100 Base-T Ethernet, 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (instrument), +1.2 kg (battery) |
| Battery Life | ~6 h (standalone) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC / 50–60 Hz or 12 VDC / 60 W |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 75 photons/count |
| SNR | VNIR 9000:1 @ 700 nm |
| SWIR1 9000 | 1 @ 1400 nm |
| SWIR2 4000 | 1 @ 2100 nm |
| Dynamic Range | 7.5×10⁹ |
| Stray Light | VNIR 5000:1 (0.02%) |
| NIR 10000 | 1 (0.01%) |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TerraSpec Halo |
| Pricing | Upon Request |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halo |
| Instrument Type | Portable |
| Application Field | General (Universities, Research Institutes) |
| Operating Principle | Grating-Based Array Detector (Non-Scanning) |
| Wavelength Range | 350–2500 nm |
| Scan Speed | 10 spectra/sec |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | ASD Halo Manager |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 × 250 × 750 mm |
| Weight (with battery) | 2.5 kg (5.5 lbs) |
| Weight (without battery) | 2.0 kg (4.3 lbs) |
| Supported Languages | English, Spanish, Chinese |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | CYPPB-01 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Relative Accuracy | < 0.5% |
| Certified Traceability | NIST-traceable calibration certificate |
| Core Technology | Critical-Orifice-Based Sonic Nozzle Dynamic Dilution |
| Construction | All-welded stainless steel flow path |
| Temperature-Controlled Path | Up to 200 °C |
| Pressure Regulation | Dual EPC with temperature compensation |
| Flow Configuration Options | Direct-coupled or high-integrity bypass |
| Purification Module | iGCSASDPure integrated gas purifier |
| Compliance | Designed for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | GC-EPD |
| Compatible Instrument | Gas Chromatograph |
| Detector Type | Plasma-Based Universal Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Excitation Source | Radio-Frequency Plasma |
| Noise Level | 0.1 mV (RMS, 1 Hz bandwidth) |
| Detection Limit | 0.5 ppb (for halogenated compounds) |
| Baseline Drift | ≤1% over 24 h |
| Signal Channels | 4 independent analog inputs |
| Calibration Accuracy & Reproducibility | ±1% (full-scale) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | IC-KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | Universal Gas Impurity Analysis |
| Compliance Framework | ASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aseeker-100Plus |
| Instrument Category | Fast Liquid Chromatography System |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure Rating | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Injection Vial Capacity | 2 mL |
| Temperature Control Range | 10–50 °C |
| Wavelength Detection Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Pump Flow Range | 0.1–50 mL/min |
| Standard Extraction Cell Volume | 40 mL (optional: 10 mL / 20 mL) |
| Standard Collection Vial Volume | 250 mL (optional: 60 mL) |
| Solvent Mixing Capability | Up to 4 solvents |
| Typical Extraction Duration | 20–30 min |
| Solvent Consumption | ~10 mL per 10 g sample |
| Required Gas Supply | Nitrogen, 0.4–1 MPa |
| Max Power Consumption | 600 W |
| Electrical Input | 100–240 VAC ±10%, 50–60 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aseeker-350Plus |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Temperature Control Range | 10–50 °C |
| Wavelength Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Cell Volume (Standard) | 120 mL |
| Pressure Accuracy | ±0.3 MPa |
| Temperature Accuracy | ±0.5 °C |
| Solvent Channels | 4 |
| Simultaneous Extraction Positions | 5 |
| Extraction Time per Batch (5 samples) | ≤20 min |
| Power Consumption | ≤1.7 kW |
| Gas Supply Requirement | N₂, 0.4–1 MPa |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aurora |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Benchtop |
| Integration Level | Fully Integrated |
| Laser Pulse Energy | 200 mJ (at 1064 nm, 5 ns FWHM) |
| Repetition Rate | Up to 100 Hz |
| Spectral Range | 190–1000 nm |
| Optical Resolution | ≤ 0.07 nm (FWHM at 300 nm) |
| Detector | Back-illuminated, deep-depletion CCD with thermoelectric cooling to −60 °C |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 mJ per pulse at 1064 nm |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-1 |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Motion Stage | X-Y travel range 100 mm × 100 mm, positioning resolution 0.2 µm |
| Spectrometer | Czerny–Turner optical design |
| Detector | Intensified CCD (ICCD) |
| Certification | CE |
| Optional Upgrade | Tandem LA Configuration |
| Power Supply | 110–240 VAC, 50/60 Hz, 5 A (10 A fuse) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Laser Pulse Duration | <500 fs |
| Repetition Rate | 1–1000 Hz (software-adjustable) |
| Wavelength | 800 nm (fundamental), optionally tunable via OPA |
| Imaging | Wide-field optical view + high-magnification telecentric microscope (up to 100×) |
| Gas Control | Digital mass flow controllers (MFCs) for Ar, He, and auxiliary gases |
| Compatibility | Quadrupole ICP-MS, multi-collector ICP-MS, and time-of-flight ICP-MS |
| Brand | ASI |
|---|---|
| Origin | USA |
| Model | J200-3 |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 213 nm (Q-switched Nd:YAG) |
| Pulse Energy | 200 mJ (adjustable) |
| Dual-Spectrometer Capability | LIBS + Optional ICP-MS Interface |
| Depth Profiling Resolution | Sub-micron per pulse (dependent on ablation rate and matrix) |
| Sample Chamber | Flex™ Modular Vacuum-Compatible Chamber with Interchangeable Liners |
| Gas Control | Dual High-Precision Digital Mass Flow Controllers (MFCs) |
| Imaging | Co-registered Dual-Camera System (High-Magnification Microscope + Wide-Field Surface View) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Type | Benchtop |
| Configuration | Modular |
| Laser Wavelength | 193 nm (Excimer) |
| Pulse Energy | 200 mJ (typical, at laser output) |
| Fluence | >20 J/cm² |
| Sample Stage Travel Range | 155 mm × 105 mm |
| Sample Capacity | 20 × 1-inch targets or 6 thin sections |
| Dimensions (W×D×H) | 119 × 89 × 195 cm |
| Weight | 750 kg (1600 lbs.) |
| Flush Time | Optimized for rapid washout (<30 s typical for standard ablation cells) |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | M3 |
| Price Range | USD 14,000 – 280,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | −30 °C to 450 °C |
| Oven Ramp Rate | 0–150 °C/min |
| Cooling Rate | 0–150 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–150 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Asicotech M6 GC System |
| Price Range | USD 21,000 – 280,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | −30 °C to 460 °C |
| Oven Ramp Rate | 0–200 °C/min |
| Oven Cool-Down Rate | 0–150 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 460 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–2000 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | M8 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| with Liquid Nitrogen Cooling | −80 °C to 450 °C |
| with CO₂ Cooling | −40 °C to 450 °C |
| Oven Ramp Rate | Up to 120 °C/min |
| Oven Cool-Down | 450 °C → 50 °C in 3.5 min |
| Carrier Gas Flow Range & Control | N₂: 0–200 mL/min (optional 500 mL/min) |
| He/H₂ | 0–1250 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 PSI |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 PSI |
| Injector Total Flow Setting Range | N₂: 0–200 mL/min (optional 500 mL/min) |
| He/H₂ | 0–1250 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | P6000+ |
| Detection Limit | ≤0.03 ppm (for target VOCs) |
| Repeatability | <1% RSD |
| Operating System | Embedded Linux |
| Power & Carrier Gas Consumption | <10% of conventional benchtop GC systems |
| Modular Interface | Standardized electrical, pneumatic, and data ports for plug-and-play detector and injector modules |
| Remote Control Capability | Full web-based instrument control and real-time data streaming via Ethernet/Wi-Fi |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ASP-660 |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Desorption Temperature Control Range | 0–45 °C |
| Valve Injection Temperature Control | Ambient |
| Transfer Line Temperature Control | Ambient |
| Cold Trap Temperature Control | 0 °C (Fixed) |
| Temperature Control Accuracy | ±1 °C at Ambient |
| Analyte Recovery Rate | ≥95% |
| Sample Position Capacity | 6 |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer | IonSense, Inc. |
| Model | ASAP |
| Instrument Type | Atmospheric Pressure Ionization Source |
| Mass Range | 5–3000 amu |
| Sensitivity | pg-level (dependent on coupled mass spectrometer) |
| Resolution | Determined by host MS platform |
| Accurate Mass Capability | Enabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF) |
| Brand | ASPEC (Prosolia) |
|---|---|
| Origin | USA |
| Model | Flowprobe |
| Instrument Type | Ambient Ion Source |
| Compatible MS Platforms | Thermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP |
| Sample Interface | Liquid Microjet Surface Sampling Probe (LMJ-SSP) |
| Spatial Resolution | ~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration) |
| Operating Mode | Real-time, continuous-flow in situ microextraction coupled with ESI ionization |
| Optical Guidance | Integrated coaxial camera for real-time probe positioning and surface navigation |
| Application Scope | Label-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Model | PST Nano-Column Heaters |
| Temperature Range | Ambient to 100°C (for heating variants) / –5°C to 60°C (PST-CHC-LT+), ±0.2°C stability |
| Heating Configurations | Butterfly-style (PST-BPH-15, PST-BPH-20), Sleeve-type (PST-CH-xxU, PST-CH-30-50U), Partial-column (PST-BCH-15, PST-BCH-30), Extended-box (PST-CH-LT-20, PST-CH-LT), Cryogenic (PST-CC, PST-CHC-LT+) |
| Compatible Column Formats | PicoFrit®, eFrit®, integrated nanoLC columns (C4, C8, C18), trap columns, emitter tips, and associated capillary tubing and fittings |
| Controller | PST-CHC-RC universal temperature controller with PID regulation and digital display |
| [Brand | AST / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM1200 |
| Excitation Source | Low-power micro-focus X-ray tube (≤10 kV, ≤0.5 mA, ≤5 W) |
| Detector | Thin beryllium-window gas-flow proportional counter |
| Measurement Time | 1–999 s (default 30 s) |
| Elements Quantified | CaO, Fe₂O₃ (simultaneously) |
| Accuracy | σ(CaO) ≤ 0.09 wt%, σ(Fe₂O₃) ≤ 0.05 wt% |
| Sample Form | Solid pellets (powder pressed into discs) |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Display | 7-inch color capacitive touchscreen |
| Data Storage | Internal non-volatile memory with power-loss retention |
| Interface | RS-232/USB for PC connectivity |
| Dimensions | 470 × 365 × 130 mm (W×D×H) |
| Weight | 15 kg] |
| Brand | AST ST |
|---|---|
| Model | DM1240 |
| Technology | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Excitation Source | Low-power micro-focus X-ray tube (≤10 kV, ≤0.5 mA, ≤5 W) |
| Detector | Ultra-thin beryllium-window proportional counter |
| Measurement Time | 1–999 s (default 60 s) |
| Accuracy | SO₃ ≤ ±0.05 wt%, CaO ≤ ±0.09 wt%, Fe₂O₃ ≤ ±0.05 wt% |
| Sample Form | Solid pellets (powder pressed into 32 mm diameter discs) |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Dimensions | 470 × 365 × 130 mm (W×D×H) |
| Weight | 15 kg |
| Operating Environment | 5–40 °C, ≤85% RH (at 30 °C), 220 V ±20 V, 50 Hz, ≤50 W |
| Radiation Class | Exempt device per Chinese regulatory requirements (no shielding enclosure required) |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Model | ASTREE LS16/48 |
| Type | Taste Analysis System |
| Sensor Technology | ChemFET-based Potentiometric Array |
| Sample Throughput | 1 sample per 3 minutes (with auto-sampler) |
| Configuration Options | 16- or 48-channel sensor array |
| Compliance | Designed for GLP/GMP-aligned laboratories, supports audit-trail-capable data management per FDA 21 CFR Part 11 requirements |
| [Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-X100 |
| Portability | Handheld / Field-Deployable |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% (w/w) |
| Repeatability | ≤ 0.1% RSD |
| Detector Options | Si-Pin or SDD (Selectable) |
| Compliance | Designed for field-deployable environmental screening per EPA Method 6200, ASTM D7298, and China’s HJ 1003–2018] |
| Brand | Atago |
|---|---|
| Origin | Japan |
| Model | ACID 5 + HIKARi 5 |
| Instrument Type | Portable |
| Parameter Types | Dual (Brix & Titratable Acidity) |
| Brix Range (HIKARi 5) | 10.0–18.0% |
| Brix Range (ACID 5) | 0.0–60.0% |
| Acidity Range | 0.10–4.00% |
| Brix Accuracy (HIKARi 5) | ±1.0% |
| Brix Accuracy (ACID 5) | ±0.2% |
| Acidity Accuracy | ±0.10% (0.10–1.00%), ±0.20% (1.01–4.00%) |
| Brix Resolution | 0.1% |
| Acidity Resolution | 0.01% (0.00–9.99%), 0.1% (≥10.0%) |
| pH Accuracy | ±0.1 pH |
| Calibration Solution Type | USA-standard buffer solutions |
| Compliance | Designed for ISO/IEC 17025-aligned routine quality control workflows |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DPH-2 Digital Portable pH Meter |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.0 to 14.0 pH |
| Resolution | ±0.1 pH (2.0–12.0 pH) |
| Accuracy | ±0.1 pH (2.0–12.0 pH) |
| Temperature Range | 0.0–50.0 °C with Automatic Temperature Compensation (ATC) |
| Calibration Points | 4.0, 7.0, and 10.0 pH buffer solutions |
| Ingress Protection Rating | IP67 |
| Power Supply | Four LR44 button cells |
| Dimensions | 4.5 × 3.0 × 16.3 cm |
| Weight | 90 g (without accessories) |
| Brand | Atik |
|---|---|
| Sensor Resolution | 1620 × 1220 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 9.0 µm × 9.0 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | <10 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TE) to −20 °C below ambient |
| Interface | USB 2.0 |
| Shutter | Electronic rolling shutter |
| Compliance | CE, RoHS, FCC Class B |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |