Chemical Analysis Instruments
Filter
Showing 4321–4350 of 10742 results
| Brand | Huifen Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HF-901D Power Transformer Oil Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry (Specialized for Electrical Insulating Oil) |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | 450 °C → 50 °C in ~8 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Detection Sensitivity (Minimum Detectable Concentration in Oil) | ≤0.1 μL/L for H₂, CH₄, C₂H₄, C₂H₆, C₂H₂, CO, CO₂ |
| Analysis Cycle Time | ≤7 min per sample |
| Temperature Stability | ±0.1 °C |
| Power Consumption | 1.9 kW |
| Dimensions (W×D×H) | 660 × 560 × 480 mm |
| Brand | Huifen Instrument |
|---|---|
| Origin | Shandong, China |
| Model | HF-901H |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring & Fuel Quality Control |
| Oven Temperature Range | Ambient + 5 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-down Time | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Min. Detectable Level: <5 pg C/s on n-hexadecane |
| Linear Dynamic Range | 10⁷ ±10% |
| Data Acquisition Rate | 20 Hz) |
| Temperature Control Precision | ±0.1 °C |
| Max Run Time | 999.99 min |
| Programmable Temperature Steps | 16 |
| Injector Options | Packed Column, Split/Splitless |
| Valve System | Configurable Auto-Controlled Valves (4-port, 6-port, 10-port, or Liquid Sampling Valve) |
| Solenoid Valve Lifetime | ≥1×10⁶ cycles (10 ms switching) |
| Brand | Huifen Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | HF-901M Automated Coal Mine-Specific Gas Chromatograph |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Mining Safety Monitoring |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Huifen Instrument |
|---|---|
| Origin | Shandong, China |
| Model | HF-901Q Gasoline PONA Analyzer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum Refining & Petrochemical QC/QA |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HF-906 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in < 3.5 min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–150 psi |
| Injector Total Flow Setpoint Range | 0–200 mL/min |
| Brand | HUIFEN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | HN-2000DS |
| Instrument Type | Benchtop Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient + 3°C to 450°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (EPC) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (EPC) |
| Injector Max Temp | 450°C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | HS-06 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient +1°C to 200°C (1°C increments) |
| Valve & Transfer Line Heating Range | Ambient +1°C to 200°C (1°C increments) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 20 mL |
| Temperature Control Accuracy | < ±0.2°C |
| Pressure Control Range | 0–0.4 MPa (continuously adjustable) |
| Method Storage | 20 user-programmable methods |
| Timing Precision | Programmable 3-event, 10-segment time sequence |
| Reproducibility | RSD ≤ 1.0% (200 ppm ethanol in water) |
| Purge Flow & Duration | Adjustable for backflush cleaning |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | GC-7820 Dedicated NMHC Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | GC-7820 Helium Ionization Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose High-Purity Gas Analysis |
| Oven Temperature Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down | 450°C → 50°C in ~8 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Detection Limit | ≤10 ppb (for CH₄) |
| Baseline Noise | ≤0.05 mV |
| Baseline Drift | ≤0.2 mV/30 min |
| Repeatability | RSD ≤3% |
| Gas Purifier Compatibility | He, Ar, Ne, Kr, Xe (residual impurities ≤10 ppb) |
| Regulatory Compliance | GB/T 16942–2009 through GB/T 28125.1–2011 |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cooling Rate | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection System | Dual FID |
| Column Configuration | Dual-column, dual-valve, dual-detector |
| Sample Introduction | Automated loop injection (0.5–1.0 mL) |
| Key Standards Compliance | GB/T 5274, ISO 6142, GB 11174, GB/T 12576, GB 19159, SH/T 0233 |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | GC-7820A |
| Oven Temperature Range | Ambient +5 °C to 450 °C |
| Max. Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | 350 °C → 50 °C in <5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max. Temp. | 450 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Independent Temperature Zones | 8 |
| Programmed Temperature Steps | 16 (expandable) |
| Max. Run Time | 999.99 min |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD, PDHID, PED |
| FID Detection Limit | ≤3.0×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene/toluene) |
| FPD Detection Limits | S ≤2×10⁻¹¹ g/s, P ≤1×10⁻¹² g/s (methyl parathion) |
| ECD Detection Limit | ≤1.0×10⁻¹⁴ g/mL (γ-HCH) |
| NPD Detection Limits | N ≤1.0×10⁻¹² g/s (azobenzene), P ≤1.0×10⁻¹² g/s (malathion) |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | GC-7820S Trace Sulfur Analyzer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down | ~8 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Photometric Detector (FPD) |
| FPD Sulfur Minimum Detectable Amount | 5 pg/s (as dodecanethiol) |
| FPD Phosphorus Minimum Detectable Amount | 0.11 pg/s (as tributyl phosphate) |
| FPD Dynamic Range (S) | 10³ |
| FPD Dynamic Range (P) | 10⁴ |
| Column Oven Programmable Temperature Steps | 16 |
| Column Oven Temperature Setting Accuracy | ±0.1 °C |
| Injector Types Supported | Packed Column, Split/Splitless |
| Valve System | Multi-position automated switching valves (4-, 6-, 10-port), electromechanical or electronic pressure/flow-controlled auxiliary valves |
| Valve Switching Speed | 10 ms |
| Rated Valve Lifetime | 1,000,000 cycles |
| Data Interface | 10/100M adaptive Ethernet with embedded TCP/IP stack |
| Display | 7-inch full-color resistive touchscreen LCD |
| Language Support | English and Chinese UI |
| Software | Dedicated sulfur analysis workstation supporting up to 253 concurrent GC systems, Modbus RTU server integration for DCS connectivity |
| Optional Configuration | Electronic Pressure Control (EPC) module with auto-ignition, flame-out recovery, and pneumatic fault self-protection |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | HF-908 |
| Instrument Type | Laboratory Gas Chromatograph |
| Oven Temperature Range | Ambient +2°C to 450°C |
| Maximum Ramp Rate | 250°C/min |
| Cool-down Time | <3.2 min (from 450°C to 50°C, with EPC) |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (EPC) |
| Carrier Gas Pressure Range & Control | 0–200 psi (EPC) |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–200 psi (customizable) |
| Injector Total Flow Setting Range | 0–1250 mL/min (customizable) |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | TD-06 |
| Type | Single-Stage Thermal Desorber |
| Gas Path Material | Passivated 316 Stainless Steel Tubing |
| Valve System | Precision Motorized 6-Port High-Temperature Valve (Low Dead Volume) |
| Sample Tube Handling | Manual Loading with Optimized Sealing Design |
| Tube Cleaning Function | Integrated Purge Cycle for Cross-Contamination Prevention |
| Temperature Control | Rapid-Heating Sample & Transfer Zones with Minimal Thermal Gradient |
| Flow Control | High-Accuracy Pressure and Mass Flow Regulation |
| Data Synchronization | TTL/Relay Trigger Output for GC and Data System Coordination |
| Method Storage | 10 User-Defined Thermal Desorption Protocols |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | TD-09 |
| Instrument Type | Laboratory Thermal Desorption Unit for Gas Chromatography |
| Application Scope | General-Purpose Volatile Organic Compound (VOC) and Semi-Volatile Organic Compound (SVOC) Analysis |
| Heating Zones | Four Independently Controlled Zones (Primary Desorption Zone, Valve Oven, Transfer Line, Secondary Desorption Zone) |
| Cooling Method | Electronic Peltier Cooling |
| Automation Level | Full Sequence Automation with GC Synchronization |
| Sample Tube Activation | Integrated Tube Conditioning Protocol |
| Compliance Support | Designed to meet ASTM D6196, ISO 16017-1, and EPA TO-17 requirements for thermal desorption sampling and analysis |
| Software Interface | RS232/USB Communication |
| GC Interface | Universal Needle Port—Mechanically Compatible with All Standard Split/Splitless Inlets (Agilent, Thermo, Shimadzu, PerkinElmer, etc.) |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | NMHF-60 |
| Detection Limit | ≤0.1 ppm (Methane), 0.05 ppm (NMHC) |
| Repeatability | RSD ≤3% (Total Hydrocarbons) |
| Weight | 11 kg |
| Power Supply | <500 W, 24 V DC |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–90% RH |
| Analysis Time | <60 s (NMHC) |
| Detector | Flame Ionization Detector (FID) |
| Linear Range | 10⁷ |
| EPC Control Precision | ±0.01 psi |
| Column Heating | Full-path heated zone (up to 200 °C) |
| Hydrogen Source | Solid-state metal hydride hydrogen generator |
| Brand | Huipu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical & Medical Device Residue Analysis |
| Detection Method | Headspace-GC/FID |
| Column | PEG-20M, 30 m × 0.32 mm × 0.5 µm |
| Oven Temp | 120 °C (isothermal) |
| Injector & Detector Temp | 150 °C |
| Carrier Gas | High-Purity N₂ (35 mL/min) |
| H₂ Flow | 35 mL/min |
| Air Flow | 350 mL/min |
| Headspace Temp | 80 °C (10 min equilibration) |
| Quantitation Range | EO: 0.1–100 µg/g |
| ECH | 3–100 ppm |
| Compliance Standards | GB/T 14233.1–2008, GB/T 16886.7–2015, ISO 10993-7:2008 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BPI Spectrophotometer |
| Price Range | USD $1,200 – $25,000 |
| Application System | Universal |
| Grating Configuration | Single-grating monochromator platform |
| Wavelength Range | 350 nm – 710 nm |
| Spectral Resolution | <10 nm (FWHM) |
| Dimensions | 6.75″ L × 6.25″ W × 5″ H |
| Weight | 8.5 lb |
| Power Supply | 110 V AC, 50/60 Hz, 1 A |
| Operating System Requirement | Microsoft Windows |
| Interface | USB 2.0 |
| Data Output | CIELAB (L*, a*, b*), Visible Transmittance (Tv), UVA Transmittance (315–400 nm) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | BPI |
| Optical Configuration | Single-beam |
| Wavelength Range | 350–710 nm |
| Spectral Bandwidth | 10 nm |
| Wavelength Automation | Automatic |
| Dimensions | 6.75" L × 6.25" W × 5" H |
| Weight | 8.5 lb |
| Power Supply | 110 V AC, 50/60 Hz, 1 A |
| Color Space Output | CIELAB (L*, a*, b*) |
| Transmittance Metrics | Visible Light Transmittance (Tv), UVA Transmittance (315–400 nm) |
| Compliance | Meets U.S. DOT and ECE R43 requirements for traffic signal visibility |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ColorFlex EZ Citrus |
| Price Range | USD 13,500 – 27,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ColorFlex EZ |
| Price Range | USD 13,500 – 27,000 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Genesys 40 |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% T |
| Control Interface | Android-based Embedded System with 7" HD Touchscreen |
| Connectivity | Integrated Wi-Fi Module |
| Sample Compartment | Front-access, Removable & Washable Liner |
| Compatible Accessories | Cuvettes, 150 mm Test Tubes (≤25 mm Ø), Smart Pipetting Accessory, Peltier Single-Cell Holder, Fiber Optic Probes, Micro-volume Cuvette Adapters |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Nano-900 |
| Spectral Bandwidth | ≤1.5 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 180–910 nm |
| Sample Volume | 0.5–2 µL |
| Optical Path Options | 0.05 mm, 0.2 mm, 1 mm |
| Light Source | Pulsed Xenon Lamp (≥10⁹ flashes) |
| Detector | 2048-pixel Linear CMOS Array |
| Absorbance Precision | 0.002 Abs (1 mm path) |
| Absorbance Range | 0.02–300 A (equivalent to 10 mm path at 260 nm) |
| DNA Quantification Range | 2–15,000 ng/µL (dsDNA) |
| Protein Quantification Range | BSA up to 400 mg/mL |
| OD₆₀₀ Range | 0–4.000 Abs |
| Measurement Time | <6 s |
| Data Output | USB storage (CSV, Excel-compatible tables |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HVE |
| Price | Upon Request |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | HG-B |
| Price | USD 2,350 (approx.) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | HyperFlux™ PRO Plus (HFPP) |
| Laser Wavelength | 785 nm |
| Safety | Integrated laser interlocks |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Spectral Resolution | High (maintained under high-throughput conditions) |
| Deployment | Benchtop & In-line Process Monitoring |
| Compliance | FDA 21 CFR Part 11, ATEX/IECEx for hazardous areas |
| Software | SpectralSoft™ v5.x |
| Brand | Elite |
|---|---|
| Particle Size | 5 µm |
| Dimensions | 4.6 mm × 250 mm |
| Stationary Phase | Hypersil GOLD C18 |
| Carbon Load | 10% |
| Pore Size | 175 Å |
| Silica Type | High-Purity Deactivated Silica |
| Endcapped | Yes |
| pH Stability Range (tested) | 1.8–10.6 |
| Aqueous Mobile Phase Compatibility | Stable in 100% aqueous conditions |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | HYSMB6-500 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | <0.5% |
| Flow Precision (RSD) | ≤0.2% |
| Maximum Operating Pressure | 8 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 2×10⁻⁵ AU (254 nm, 1 mL/min, methanol) |
| Data Acquisition Frequency | 5 Hz |
| Column Configuration | 8-column rotary valve system |
| Column Volume | 500 mL per column |
| Feed Flow Range | 0.5–10 mL/min |
| Eluent Flow Range | 0.5–15 mL/min |
| Product Flow Range | 0.1–30 mL/min |
| System Voltage | 220 V ±10%, 50 Hz |
| Total Power Consumption | 2 kW |
| Dimensions (W×D×H) | 450 × 450 × 800 mm |
| Weight | 3.0 kg |
| Communication Interface | RS-485 for external control and SCADA integration (e.g., KingView) |
| Brand | I-CHEQ |
|---|---|
| Origin | USA |
| Model | F2-9000 |
| Application | Handheld/Field-Portable |
| Element Range | Mg–Pu |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | 120–140 eV |
| Repeatability | 0.1% |
| Detector | High-Resolution Silicon Drift Detector (SDD) |
| Excitation Source | Variable-Voltage (up to 50 kV) Microfocus X-ray Tube with Selectable Anode Materials (Au, Ag, W, Ta, Pd) |
| Cooling | Peltier Semiconductor |
| Operating System | Windows CE |
| Display | Industrial-Grade TFT Color Touchscreen |
| Dimensions (L×W×H) | 233 × 84 × 261 mm |
| Weight (with battery) | 1.46 kg |
| Compliance | Meets IEC 61000-6-3 (EMC), IEC 61000-6-2, ANSI N43.3, and FDA 21 CFR Part 1020.40 for X-ray safety |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |