| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HS2048XL-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 pixels) |
| Resolution (FWHM) | 1–20 nm (configuration-dependent) |
| Sensitivity | 1,250,000 counts/µW·ms |
| Signal-to-Noise Ratio | 525:1 |
| Stray Light | < 1% |
| Dynamic Range | 200–1160 nm |
| Numerical Aperture | 0.22 |
| Focal Length | 37.5 mm |
| Integration Time | 2 µs – 600 s |
| A/D Conversion | 16-bit, 1 MHz |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Data Acquisition Rate | 2.44 ms per scan (with on-board averaging) |
| Digital I/O | HD-26 connector with 2 analog inputs, 2 analog outputs, 3 digital inputs, 12 digital outputs, trigger & sync support |
| Power Supply | USB-powered (700 mA) or external 12 VDC (360 mA) |
| Dimensions & Weight | 175 × 165 × 85 mm, 1.95 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HSC1024x58TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD |
| Resolution (FWHM) | 0.2–7 nm (configurable) |
| Sensitivity | 445,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 1200:1 |
| Dynamic Range | 40,000 |
| Stray Light | 0.5% |
| Optical Platform | Symmetrical Czerny-Turner, f = 100 mm, NA = 0.13 |
| Cooling | Single-stage thermoelectric (TEC) |
| ADC | 16-bit, 250 kHz |
| Integration Time | 5.2 ms – 60 min |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 I/O connector |
| Dimensions | 185 × 161 × 185 mm |
| Weight | 3500 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR-Mini |
| Spectral Range | 900–1750 nm |
| Detector | InGaAs (256-pixel array) |
| Optical Resolution | 6 nm (typical, slit- and grating-dependent) |
| Sensitivity (HS mode) | 665,000 counts/µW/ms (integrated over 1000–1750 nm) |
| Signal-to-Noise Ratio (HS) | 1900:1 |
| Dynamic Range (HS) | 4750:1 |
| Stray Light | <1% |
| A/D Converter | 16-bit, 500 kHz |
| Integration Time (HS) | 10 µs – 300 ms |
| Interface | USB 2.0 (480 Mbps), fiber-coupled input, 50 cm integrated cable |
| Dimensions | 95 × 68 × 20 mm |
| Weight | 185 g |
| Operating Temperature | 0–55 °C |
| Software Compatibility | AvaSoft v8+, Windows/Linux DLL support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR256-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan (USB 3.0) |
| Integration Time | 10 µs – 500 ms |
| Detector | 256-pixel InGaAs linear array (50 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| Dynamic Range | 6000:1 (HS mode), 9000:1 (LN mode) |
| SNR | 1900:1 (HS), 5000:1 (LN) |
| Sensitivity | 8.2 × 10⁶ counts/µW·ms (HS, 1000–1750 nm) |
| ADC | 16-bit, 500 kHz |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft v8+ with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NIR256-1.7-HSC-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.13 ms/scan |
| Data Sampling Interval | 0.4 ms/scan |
| Measurement Mode | Transmission/Reflection |
| Optical Design | Symmetrical Czerny-Turner, 100 mm focal length, 1-stage TE-cooled |
| Detector | TE-cooled InGaAs linear array (256 × 50 µm × 500 µm) |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| AD Converter | 16-bit, 1.2 MHz |
| Integration Time (HS mode) | 20 µs – 500 ms |
| Integration Time (LN mode) | 20 µs – 20 s |
| Dynamic Range (HS/LN) | 4900:1 / 7600:1 |
| SNR (HS/LN) | 1900:1 / 5000:1 |
| Gain Modes | High Sensitivity (HS) and Low Noise (LN) |
| Grating Options | Four selectable, exchangeable gratings |
| Slit Options | Interchangeable slits (25–500 µm) |
| Digital I/O | HD-26 connector with 13 bidirectional digital I/O lines, 2 analog inputs/outputs, trigger/sync/gate/laser control |
| Operating Temperature | 0–40 °C |
| Cooling | ΔT = 24 °C below ambient |
| Dimensions & Weight | 185 × 160 × 184 mm, 3.6 kg |
| Software | AvaSoft suite with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR512-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan |
| Data Sampling Interval | 0.53 ms/scan |
| Detector | 512-pixel InGaAs linear array (25 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| AD Converter | 16-bit, 500 kHz |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| Integration Time | 10 µs – 10 s |
| Dynamic Range | up to 9000:1 (LN mode) |
| SNR | up to 5000:1 (LN mode) |
| Trigger & I/O | HD-26 connector with 13 digital I/O lines, 2 analog in/out, TTL trigger, sync, strobe, laser control |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft suite with chemometrics support |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048CL-EVO |
| Spectral Range | 200–1100 nm |
| Detector | CMOS linear array (2048 pixels) |
| Optical Resolution (FWHM) | 0.06–20 nm (configuration-dependent) |
| Sensitivity | 375,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 300:1 |
| Dynamic Range | 4000:1 |
| Stray Light | 0.19–1.0% (grating-dependent) |
| AD Converter | 16-bit, 6 MHz |
| Integration Time | 9 µs – 59 s |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Sampling Speed | 0.38 ms/spectrum (USB3), 1.0 ms/spectrum (Ethernet) |
| I/O | HD-26 connector with 2 analog in/out, 13 digital I/O, trigger/sync/laser control |
| Power | USB 3.0 (500 mA) or 12 VDC (300 mA) |
| Dimensions & Weight | 177 × 127 × 44.5 mm, 1135 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels, 0.89 mm height) |
| Optical Resolution | 0.09–20 nm (configuration-dependent) |
| Sensitivity | 650,000 counts/µW per millisecond |
| Signal-to-Noise Ratio | 450:1 |
| Stray Light | <1% |
| AD Converter | 16-bit, 1.33 MHz |
| Integration Time | 2.4 ms – 25 s |
| Read Noise | 7.5 counts RMS |
| Data Transfer Rate | 2.44 ms/scan (USB 3.0) |
| Interface | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (885 mA) or 12 VDC (420 mA) |
| Dimensions & Weight | 175 × 127 × 44.5 mm, 1180 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels) |
| Resolution (FWHM) | 0.09–20 nm (configurable via slit width & grating) |
| Sensitivity | 300,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 550:1 |
| Stray Light | <1% |
| Dark Noise Reduction | 2–3× via thermoelectric cooling |
| Cooling Delta | −35 °C relative to ambient |
| Integration Time | 9.7 ms – 500 s |
| A/D Converter | 16-bit, 500 kHz |
| Interface | USB 2.0 (480 Mbps) / RS-232 (115.2 kbps) |
| Optical Design | Symmetric Czerny-Turner, 75 mm focal length |
| Power Supply | 5 VDC, 3.0 A (instrument) |
| Dimensions & Weight | 250 × 179 × 144 mm, 3.6 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NEXOS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (NEXOS™, 2K) / 365:1 (PNEXOS™, 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Communication Interfaces | USB (NEXOS™), RS232/SPI (NEXOS™ Link), Optical Bench Only (NEXOS™ Bench Only) |
| Optical Design | Symmetric Czerny-Turner |
| Pixel Options | 2048 or 4096 |
| Slit Options | Configurable slit widths |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | VARIUS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (VARIUS™ 2K) / 365:1 (VARIUS™ 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner with 50 mm focal length |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full Speed (Type-C), optional UART/SPI/I²C |
| ADC | 16-bit, 2 MHz |
| Power | 5 V via USB or auxiliary connector (4.4–5.5 V), ≤ 70 mA |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –40 to +70 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | ARIS Compact |
| Spectral Range | UV–VIS–NIR (configurable) |
| Optical Resolution (FWHM, typical) | 0.33–1.10 nm |
| Detector Options | Toshiba TCD1304DG (3648 px) or Hamamatsu S11639-01 (2048 px) |
| Integration Time | 3 µs – 35 min (TCD1304DG) |
| Stray Light Suppression | < 0.01% @ 600 nm |
| SNR | 350:1 (TCD1304DG), 600:1 (S11639-01) |
| Dynamic Range | 1900:1 (TCD1304DG), 5000:1 (S11639-01) |
| Pixel Readout Rate | 1 MHz / 2 MHz |
| Trigger Jitter | ≤10 µs |
| Slit | User-replaceable 20 µm default (optional slits available) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aris |
| Price | Upon Request |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | Aris Miniature Spectrometer |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD/CMOS |
| Resolution (FWHM) | 0.33–1.40 nm (typ.) |
| Signal-to-Noise Ratio | 350 or 600 (max., unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 (single-pixel, unaveraged) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetrical Czerny-Turner |
| Focal Length | 50 mm |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable, default 20 µm |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed, UART |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +70 °C |
| Humidity | 0–90% RH (non-condensing) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Detector Type | CCD |
| Spectral Range | 350–840 nm |
| Resolution (FWHM) | 0.65 nm (typ.), 0.80 nm (max.) |
| Signal-to-Noise Ratio | 350 (Toshiba TCD1304DG), 600 (Hamamatsu S11639-01) |
| Dynamic Range | 1900:1 (Toshiba), 5000:1 (Hamamatsu) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner, f = 50 mm, NA = 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full-Speed (Type-C), SMA fiber port |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Resolution (FWHM) | down to 0.05 nm |
| Spectral Sampling | 4096 pixels |
| Slit Width (standard) | 10 µm |
| Stray Light | < 0.1% |
| Dynamic Range | 5500:1 (typ.), 1900:1 to 5000:1 (configurable) |
| Signal-to-Noise Ratio | 350–600 (typ. 550, unaveraged) |
| Optical Design | Symmetric Czerny-Turner |
| Focal Length | 120 mm |
| Numerical Aperture | 0.07 |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Power Supply | 4.4–5.5 V DC (via USB or Aux), ≤70 mA |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Optical Resolution (FWHM) | 0.05–1.40 nm (configurable) |
| Sensitivity | 0.05 nm resolution mode |
| Signal-to-Noise Ratio | 350 or 600 (typ.), up to 550 (spec.) |
| dynamic range | 1900:1 or 5000:1 (spec.) |
| Stray Light | < 0.08 % |
| Focal Length | 120 mm |
| Slit Width (standard) | 10 µm |
| Pixel Count | 4096 |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ARIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Sie na |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Array |
| Optical Resolution (FWHM) | 8 nm (typ.), up to 15 nm (max.) |
| Signal-to-Noise Ratio | 1000 (unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Entrance Slit | 20 µm (user-replaceable) |
| Interface | USB 2.0 Full-Speed, UART, optional SPI/I²C |
| Power Supply | 5 V DC (4.4–5.5 V), ≤ 60 mW |
| Dimensions | 52.0 × 57.0 × 17.0 mm |
| Weight | 80 g |
| Operating Temperature | –20 °C to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Law |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Linear Array |
| Optical Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Detector Type | InGaAs Linear Array (Non-Cooled) |
| Spectral Range | 900–1700 nm / 800–1900 nm / 900–2100 nm |
| Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Entrance Slit | User-Replaceable (default 20 µm) |
| Optical Design | Symmetric Czerny-Turner, f = 30 mm, NA = 0.19 |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Power | 5 V DC (4.4–5.5 V), ≤60 mW |
| Dimensions | 52.0 × 57.0 × 17.0 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Array |
| Optical Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 8 nm |
| Signal-to-Noise Ratio | 1000 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | AWSensors |
|---|---|
| Origin | Spain |
| Model | QCM-D |
| Channel Options | 1-channel or 4-channel modular system |
| Sensor Interface | AT-cut quartz crystals with Cr/Au/Ti electrodes |
| Cell Design | Patented quick-lock mechanism with FFKM or PDMS sealing |
| Measurement Modes | Static (Batch) and dynamic flow-through (Flow) |
| Software Platform | AWSensors Control & Analysis Suite |
| Compliance Framework | Designed for GLP-compliant data integrity |
| Optional Modules | Temperature control unit (±0.1 °C stability), precision flow control unit (integrated dual-position, six-port valve with degassing module), potentiostat integration for electrochemical QCM (EQCM) |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Model | CHRONECT LC-GC |
| Temperature Control Range | 4–450 °C |
| Oven Ramp Rate | up to 120 °C/min |
| Oven Cool-down Rate | up to 100 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 pressure segments) |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AxiChrom Master |
| Instrument Type | Dynamic Axial Compression System |
| Regulatory Compliance | 21 CFR Part 11 compliant software |
| Column Diameter Range | 300–2000 mm |
| Operation Mode | Automated column packing with preloaded and user-editable packing methods |
| Brand | AZ Technology |
|---|---|
| Origin | USA |
| Model | LPSR300 |
| Spectral Range | 250–2800 nm |
| Measurement Type | Spectral Total Hemispherical Reflectance |
| Repeatability | ±1% (250–2500 nm), ±2% (2500–2800 nm) |
| Spectral Resolution | Better than 5% of wavelength (250–2500 nm), better than 8% of wavelength (2500–2800 nm) |
| Sample Diameter | ≥0.5 inch |
| Full Scan Time | <2 minutes |
| Power Supply | 115 VAC / 60 Hz |
| Measurement Head Dimensions | 10 × 12 × 8 in |
| Measurement Head Weight | 15 lb |
| PC/Power Box Dimensions | 9 × 16 × 20 in |
| PC/Power Box Weight | 35 lb |
| Warranty | 1 year parts and labor |
| Compliance | ASTM E903, NASA-qualified design |
| Operating System | Windows XP (embedded) |
| Integrated Optical Database | Yes |
| Vacuum-Compatible Variant | LPSR300V available |