| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System |
| Quotation | Upon Request |
| Instrument Type | Time-of-Flight (TOF) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System with ACQUITY Premier |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Software Platform | UNIFI Scientific Information System |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Breeze HPLC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Configuration | Modular Benchtop HPLC Platform |
| Target Users | Academic Teaching Labs, Regulatory QC Laboratories, Early-Stage R&D Facilities |
| Software | Breeze™ Chromatography Data System (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 1525EF |
| Instrument Type | High-Pressure Semi-Preparative HPLC System |
| Application Level | Laboratory-Grade |
| Configuration | Dual-Flow Path Architecture (Analytical + Semi-Prep) |
| Sample Throughput | Single to High-Volume Batch Processing |
| Brand | Waters |
|---|---|
| Model | Breeze2 GPC |
| Origin | USA |
| Instrument Type | Ambient-Temperature SEC System |
| UV Detector Noise | 1.5 × 10⁻⁹ RIU |
| Column Oven Temperature Range | 5 °C above ambient to 60 °C |
| Detection Modes | UV/Vis (2489), Refractive Index (2414) |
| Pump | 1500 Solvent Delivery Module |
| Autosampler | 2707 |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Breeze™ 2 HPLC |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical & Semi-Preparative Use |
| Flow Rate Range | Analytical mode: 0–10 mL/min |
| Semi-preparative mode | 0–22.5 mL/min |
| Maximum Pressure | 6000 psi |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | Analytical: 0.1–100 µL |
| Semi-preparative | 0–10 mL |
| Temperature Control | Optional column oven (configurable per system setup) |
| Wavelength Ranges | UV-Vis detector (2489): 190–700 nm |
| PDA detector (2998) | 190–800 nm |
| Fluorescence detector (2475) | Excitation 200–890 nm, Emission 210–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Charged Aerosol Detector |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | DESI XS |
| Compatibility | SELECT SERIES Cyclic IMS, SYNAPT XS, Xevo G2-XS QTof |
| Ionization Principle | Desorption Electrospray Ionization (DESI) |
| Environmental Sealing | Partially Enclosed Housing |
| Integrated Imaging | Side-View Camera for Spray-Sample Alignment |
| Motion Control | Stepper-Motor Stage with S-Curve Acceleration Algorithm |
| Automation | Auto-shutoff for Solvent Gas & High Voltage |
| Software Integration | HDI™ Software for High-Resolution Mass Spectrometry Imaging |
| Regulatory Context | Designed for GLP/GMP-compliant imaging workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | E2695 |
| Instrument Type | Fast Liquid Chromatography System |
| Maximum Pressure | 34.5 MPa |
| Sample Capacity | 120 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Flow Rate Range | 0.001–10.000 mL/min |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV/Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | Up to 80 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Investigator SFC System |
| Application Level | Laboratory Grade |
| Instrument Type | Semi-Preparative Supercritical Fluid Chromatography System |
| Flow Rate Range | Up to 15 mL/min |
| Column Capacity | Up to 10 analytical columns or 6 preparative columns |
| Integrated Autosampler | Waters Alias |
| Software Platform | SuperChrom |
| Optional Detectors | 2998 Photodiode Array (PDA) Detector, 2424 Evaporative Light Scattering (ELS) Detector |
| Dimensions (H×L×W) | 92 cm × 98 cm × 68 cm |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ionKey/MS |
| Category | Mass Spectrometry Integrated Microfluidic Separation Platform |
| Compatibility | Designed for Waters Xevo TQ-S, Xevo G2-XS QTof, and other Waters MS platforms with iKey-compatible ion sources |
| Column Format | Monolithic 150 µm ID microfluidic channel packed with 1.7 µm BEH particles |
| Equivalent Chromatographic Performance | Comparable to 2.1 mm ID UPLC columns |
| Sensitivity Enhancement | Up to 5–10× vs. conventional 2.1 mm ID UPLC-MS |
| Solvent Consumption | <5 µL/min typical flow rate |
| Interface Type | Integrated electrospray ionization (ESI) source with embedded heater, e-cord™ electronics, and plug-and-play fluidic/electrical coupling |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LC-2695 |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | ~50 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | PATROL UPLC |
| Instrument Type | Real-time In-line/At-line UPLC-based PAT System |
| Regulatory Alignment | Designed for FDA QbD and ICH Guidelines |
| Deployment Mode | Integrated Process Analytical Technology (PAT) Platform |
| Operational Architecture | Fully Automated, 24/7 Unattended Operation |
| Diagnostics | On-board Self-Diagnostics with Remote Monitoring Capability |
| Connectivity | Ethernet/IP-enabled for Distributed Control System (DCS) and Manufacturing Execution System (MES) Integration |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and GLP/GMP Data Integrity Requirements |
| Sample Introduction | Configurable for At-line Flow-Through Cells or Direct In-line Probes (with Optional Valving & Filtration Modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 100q SFC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative SFC System |
| Flow Rate Range | Up to 100 mL/min |
| Mobile Phase | CO₂-based supercritical fluid (co-solvent compatible) |
| Fraction Collection | Automated open-loop collection with UV- or MS-triggered modes |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Separation Mode | Chiral and achiral preparative separations |
| Sample Scale | Milligram- to gram-scale purification |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 150 |
| Application Level | Laboratory-grade |
| Instrument Type | High-pressure preparative LC |
| Pump Configuration | Binary or Quaternary (low-pressure solvent selection or high-pressure gradient mixing up to 150 mL/min) |
| Detector Options | 2489 UV/Vis or 2998 Photodiode Array (PDA) |
| Column Compatibility | Up to 50 mm internal diameter |
| Sample Load Range | Milligram- to gram-scale purification |
| Software | ChromScope™ for method development, fraction simulation, and GLP-compliant data handling |
| Compliance | Designed to support 21 CFR Part 11–ready workflows with audit trail and electronic signature capability (when configured with appropriate IT infrastructure) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prep SFC 150 AP System |
| Instrument Type | Preparative |
| Detector Types | None |
| Maximum Pressure | Not Specified |
| Flow Rate Range | Not Specified |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep SFC 150 Mgm |
| Type | Preparative |
| Maximum CO₂ Flow Rate | 150 mL/min |
| Modifier Flow Range | Up to 150 mL/min |
| Fraction Collection Positions | 6 × 2 L |
| Operating System | Windows 10 |
| Control Software | Waters ChromScope 2.0 SFC |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Preparative Supercritical Fluid Chromatography (SFC) System |
| Model Variants | 80, 200, 350 |
| Application Level | Laboratory-Scale Purification |
| Regulatory Context | Designed for GLP-compliant workflows and compatible with FDA 21 CFR Part 11–enabled software environments |
| Compliance Framework | Supports ASTM D7894–21 (Standard Guide for SFC Method Development), ISO 17025–2017 (Testing Laboratory Competence), and USP <621> Chromatography guidelines |
| Software Platform | SuperChrom v3.x (with audit trail, electronic signatures, and method versioning) |
| Detection | UV-Vis absorbance detection (dual-wavelength capability) |
| Fraction Collection | Automated, timed or peak-triggered, with solvent compatibility up to 100% CO₂-expanded liquids and polar modifiers (e.g., methanol, ethanol, isopropanol) |
| Back Pressure Control | Active Automatic Back Pressure Regulator (ABPR) with ±0.2 bar pressure stability |
| Solvent Delivery | Dual-pump architecture — primary CO₂ pump (supercritical phase delivery) and auxiliary modifier pump (liquid-phase co-solvent gradient) |
| System Architecture | Modular, rack-mounted configuration with integrated safety interlocks, CO₂ phase monitoring, and real-time density compensation |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | RADIAN ASAP |
| Ionization Principle | Atmospheric Pressure Solid Analysis Probe (ASAP) |
| Mass Analyzer | Single Quadrupole |
| Detection Mode | Full Scan / Selected Ion Monitoring (SIM) |
| Sample Introduction | Direct Solid & Liquid Analysis |
| Software Platform | LiveID, IonLynx, OpenLynx |
| Compliance Support | FDA 21 CFR Part 11 (audit trail, electronic signature), GLP/GMP-ready workflows |
| Dimensions | Compact benchtop footprint (< 60 cm width) |
| Typical Analysis Time | < 30 seconds per sample |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SELECT SERIES Cyclic IMS |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SELECT SERIES MRT |
| Mass Analyzer Type | Multi-Reflecting Time-of-Flight (MRT-TOF) |
| Instrument Class | High-Resolution Accurate-Mass (HRAM) LC-MS/MS System |
| Application Scope | Universal (Life Sciences, Clinical Research, Forensics, Materials Surface Analysis) |
| Pressure Range | Not Applicable (Vacuum-operated analyzer) |
| Ion Sources Supported | DESI XS, SELECT SERIES MALDI, Electrospray (ESI), APCI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SQD2 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Compatibility | UPLC, HPLC, UPC², SFC, Prep-LC, Prep-SFC, ASAP Direct Analysis |
| Ionization Modes | ESI, APCI, UniSpray, ZSpray |
| Mass Range | 0–3000 m/z |
| Software Platform | MassLynx, OpenLynx Open Access, AutoPurification Integration |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYNAPT XS |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | Universal |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | TQD |
| Configuration | Integrated UPLC/MS/MS System |
| Ionization Options | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Range | 50–1200 m/z |
| Typical MRM Sensitivity | <10 fg on-column for reserpine (S/N ≥ 20:1) |
| Scan Speed | Up to 8,000 Da/sec in MRM mode |
| Collision Cell | T-Wave™ RF-only quadrupole collision cell |
| Data Acquisition Rate | ≥20 MRM transitions/sec |
| Software Platform | MassLynx v4.1 with TargetLynx, QuanLynx, QCMonitor, RADAR, TrendPlot, InliStart, and Quanpedia modules |
| Compliance | Fully compatible with 21 CFR Part 11 audit trail requirements and GLP/GMP workflows |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo CDMS |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Model | Xevo G3 QTof |
| Application Scope | Universal LC-MS/MS Platform |
| Mass Range | Not specified in source data |
| Resolution | Not specified in source data |
| Mass Accuracy | Not specified in source data |
| Sensitivity | Not specified in source data |
| Pressure Range | Not specified in source data |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo MRT |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Resolution | 100,000 FWHM at 100 Hz |
| Mass Accuracy | <500 ppb |
| m/z Range | Broad, consistent across full scan range |
| Analyzer Architecture | Multi-Reflecting Time-of-Flight (MRT) with 4-meter effective flight path and 8 reflections |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | Universal LC-MS/MS Quantitation |
| Mass Range | Not specified by manufacturer in public datasheets |
| Sensitivity | Up to 15× higher for challenging negative-ion-mode analytes vs. prior-generation TQ systems |
| Resolution | Unit mass resolution standard for SRM/MRM transitions |
| Mass Accuracy | Not specified (typical for QqQ: ±0.1–0.2 Da under routine conditions) |
| Operating Pressure Range | Vacuum system maintained at <1×10⁻⁶ mbar in analyzer region |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute XR |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | Universal LC-MS/MS Analysis |
| Mass Range | Not Specified by Manufacturer |
| Sensitivity | Not Specified by Manufacturer |
| Resolution | Not Specified by Manufacturer |
| Mass Accuracy | Not Specified by Manufacturer |
| Operating Pressure Range | Not Specified by Manufacturer |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-GC |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Gas Chromatography (GC) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) |
| Software Platform | TargetLynx™, Quanpedia™, IntelliStart™ |
| Compliance Framework | Designed for GLP/GMP environments |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) in triple quadrupole configuration |